ERA 500 Hybrid IP Safety and Installation Manual

P R O T E C T I O N   F R O M   B U R N S   A N D   F I R E

• The exterior of the fixture becomes hot during use. After 5 minutes of operation a surface temperature of 

60° C (140° F) shall be expected. The maximum steady state surface temperature is also 60° C (140° F). 
Avoid contact by persons and materials.

• Allow the fixture to cool for at least 60 minutes before handling.

• Keep all combustible materials (e.g. fabric, wood, paper) at least 0.2 m (8 in.) away from the fixture.

• Keep flammable materials well away from the fixture.

• Ensure that there is free and unobstructed airflow around the fixture.

• Provide a minimum clearance of 0.2 m (8 in.) around fans and air vents.

• Do not illuminate surfaces within 10 m (33 ft.) of the fixture.

• Do not expose the front glass to sunlight or any other strong light source from any angle. Lenses can 

focus the sun's rays inside the fixture, creating a potential fire hazard. 

• Do not attempt to bypass thermostatic switches or fuses.

• Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F).

• Do not modify the fixture in any way not described in this manual or the fixture’s User Guide or install other 

than genuine Martin parts. Do not stick filters, masks or other materials onto any lens or other optical 
component. Use only accessories approved by Martin to mask or modify the light beam.

P R O T E C T I O N   F R O M   E Y E   I N J U R Y

• This fixture corresponds to Risk Group 3 according to EN 62471 when all photobiological risks are 

considered and Risk Group 2 product according to IEC/TR 62778 for blue light only. It emits possibly 
hazardous optical radiation. It falls into the Risk Group categories shown below according to both EN 
62471 and IEC/TR 62778 under worst-case conditions:

• At a distance of less than 19.2 m (63 ft.) from the fixture, the light output can potentially cause eye or skin 

injury before an exposed person's natural aversion responses (blink reflex and reaction to skin discomfort) 
can protect them. At distances greater than 19.2 m (63 ft.), potential eye and skin injury hazards from the 
light output are normally prevented by natural aversion reflexes.

• Position the fixture so that persons cannot be exposed to the fixture's light output at a distance of less 

than 19.2 m (63 ft.) from the fixture, and so that prolonged staring into the light output at less than 115 m 
(378 ft.) from the fixture is not expected.

• Do not look directly into the fixture’s light output.

• Do not look at the light output with magnifiers, telescopes, binoculars or similar optical instruments that 

may concentrate the light output.

• Ensure that persons are not looking at the fixture when the fixture lights up suddenly. This can happen 

when power is applied, when the fixture receives a DMX signal, or when certain control menu items are 
selected.

• Disconnect the fixture from power at all times when the fixture is not in use.

• Provide well-lit conditions to reduce the pupil diameter of anyone working on or near the fixture.

P R O T E C T I O N   F R O M   I N J U R Y

• Fasten the fixture securely to a fixed surface or structure when in use. The fixture is not portable when 

installed.

• Do not lift or carry the fixture alone.

• Use two evenly spaced omega brackets with clamps to suspend the fixture from rigging structures. Do not 

use only one clamp.

• When clamping the fixture to a truss or other supporting structure, use two half-coupler clamps. Do not 

use G-clamps, quick-trigger clamps or any other type of clamp that does not completely encircle the 
supporting structure when fastened.

DO NOT

RISK GROUP

3

RISK GROUP

2

0.29 m

(11.5 ins.)

19.2 m

(63 ft.)

115 m

(378 ft.)

USE

1150 m

(3773 ft.)

RISK GROUP

1

RISK GROUP

EXEMPT

Содержание Martin ERA 500 Hybrid IP

Страница 1: ...ERA 500 Hybrid IP Safety and Installation Manual...

Страница 2: ...for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Marti...

Страница 3: ...9 AC power 11 Power input 11 Data links 13 DMX and RDM 13 Service and maintenance 14 Managing humidity 14 Pressure relief valves 15 Dehumidifying the fixture 15 Vacuum testing 16 Cleaning 17 Lubricati...

Страница 4: ...RA 500 Hybrid IP check the Martin website and make sure that you have the latest user documentation for the fixture Document revisions are indicated at the bottom of page 2 This product is for profess...

Страница 5: ...hat are accessible and live at high voltage while the fixture is connected to power and that remain under tension for up to five minutes after power is disconnected Wait for at least five minutes afte...

Страница 6: ...8 under worst case conditions At a distance of less than 19 2 m 63 ft from the fixture the light output can potentially cause eye or skin injury before an exposed person s natural aversion responses b...

Страница 7: ...8 2 17 Section 17 6 6 or BGV C1 DGUV 17 and must be capable of bearing a static suspended load at least six times or more if required by locally applicable regulations the weight that it secures Elimi...

Страница 8: ...for complex projections and mid air effects For the latest firmware updates documentation and other information about this and all Martin products please visit the Martin website at http www martin co...

Страница 9: ...or shade the head so that the front lens will not be exposed to sunlight or another strong light source from any angle even for a few seconds See Figure 1 The ERA 500 Hybrid IP s lens can focus the s...

Страница 10: ...rom a stable platform hang the fixture on the truss with the front facing towards the area to be illuminated Tighten the rigging clamps 5 See Figure 5 Install a safety cable that is approved as a safe...

Страница 11: ...urce The power cable can be hard wired to a building installation circuit or fitted with a mains plug cord cap to allow connection to local AC mains power outlets If you install a mains plug on the po...

Страница 12: ...h clicks and that the connector is locked into the socket 3 If operating outdoors in wet conditions or in conditions where condensation may appear ensure that all cables arrive from below connectors C...

Страница 13: ...ot overload the DMX data link You can connect up to a maximum of 32 devices on a serial DMX link Install a DMX termination plug on the last fixture on the link Connecting to data via DMX cable To conn...

Страница 14: ...rface see Related Items on page 26 and the Martin Companion software suite available for download free of charge from the Martin website at www martin com All other service operations on the ERA 500 H...

Страница 15: ...ronment where airborne dust or dirt is present we recommend that you replace the valves with their rubber seals each time you replace the lamp If heavy dust or dirt is present and the fixture is power...

Страница 16: ...ent You will need the following items Vacuum tester you can obtain a suitable tester from Martin see Related Items on page 26 M12 x 1 5 adapter available from Martin see Related Items on page 26 to co...

Страница 17: ...head by wiping gently with a soft clean lint free cloth moistened with a weak detergent solution Do not rub the surface hard lift particles off with a soft repeated press Dry with a soft clean lint f...

Страница 18: ...create a safety hazard Replacement lamps are available from Martin see Spare parts on page 26 The lamp bulb and reflector must be perfectly clean when you install the lamp Do not touch them with your...

Страница 19: ...wed on the left hand side of the lamp compartment just above the horizontal lamp adjustment screw Do not confuse the two screws the lamp slider locking screw is smaller than the horizontal lamp adjust...

Страница 20: ...sealed to its original IP65 level carry out a vacuum test as described in Dehumidifying the fixture on page 15 19 Each time you install a new lamp reset the lamp lifetime counter in the fixture s cont...

Страница 21: ...ear cover fan is disconnected 7 See Figure 15 Turn the two Torx 20 lamp adjustment screws A for vertical adjustment and B for horizontal adjustment until you obtain the most even projection 8 Shut dow...

Страница 22: ...fore applying power to the fixture Read the safety information section of this manual starting on page 4 Read Connecting to power on page 11 Check that the installation is safe and secure Check that t...

Страница 23: ...ERA 500 Hybrid IP on the data link Incorrect addressing of fixtures Check fixture address and protocol settings One of the fixtures is defective and is disturbing data transmission on the link Unplug...

Страница 24: ...Motorized Pan 540 coarse fine control and speed Tilt 260 coarse fine control and speed Control and Programming Control options DMX RDM 16 bit control Dimming pan and tilt Setting and addressing Contr...

Страница 25: ...perature steady state at Ta 40 C 60 C 140 F Maximum ambient temperature Ta max 40 C 104 F Minimum ambient temperature Ta min 20 C 4 F Maximum total heat dissipation calculated 10 2120 BTU hr Allow for...

Страница 26: ...n Companion software suite incl firmware uploader Free download from www martin com Martin Companion Cable USB DMX hardware interface P N 91616091 Martin RDM 5 5 Splitter P N 90758150 Martin Vacuum Te...

Страница 27: ...nformity for this product The Declaration of Conformity is available for download from the ERA 500 Hybrid IP area of the Martin website at www martin com Canadian Interference Causing Equipment Regula...

Страница 28: ...www martin com...

Отзывы: