Martin® ELP WW IP User Manual
15
If you install a power plug on a 12 AWG / 2.5 mm
2
power input cable, install a grounding type
(earthed) plug with integral cable grip that is rated minimum 16 A, 250 V.
Power relay cables
If you connect fixtures to power in a daisy-chain, we recommend that you use the 16 amp rated
12 AWG / 2.5 mm
2
power relay cables available from Martin
(see ‘Accessories’ on page 34) to link
fixtures
’ MAINS OUT sockets to MAINS IN sockets. Using the 16 A rated relay cables available as
accessories from Martin, you can link:
Maximum four (4) ELP WW IP fixtures in total at 100-120 V, or
Maximum nine (9) ELP WW IP fixtures in total at 200-240 V.
Do not exceed these limits.
If you create custom power relay cables, use only the Neutrik PowerCON TRUE1 TOP connectors
listed under “Accessories” on page 34.