background image

Magnafire Series Coal Stoves

3

3-90-70746R11_06/13

Introduction

Thank you for purchasing a Harman® Magnafire coal stove. The Magnafire series has been designed and built to last. 

Whether you’re heating a room or heating your whole house, you’ve made the right choice. Please read this entire instruction 

manual before attempting to install or operate your new stove. If you have further questions regarding your new stove, 

contact your Harman® dealer. Follow these instructions and you will have many years of warmth and comfort enjoying your 

new coal stove.
If you are a first-time coal burner, keep in mind that you will not have instant success with maintaining a fire. No one does. 

Following these instructions should help you with the basic principals.

Safety Notice:

Stove is hot while in operation. Keep combustibles such as furniture, fuel, and draperies at least 36 inches away 

from the appliance.
Do not leave small children unattended while in the room with this heater.
Always wear gloves when attending to the stove.

This stove is not an incinerator. Do not burn garbage, painted or treated wood, or flammable liquids like gasoline 

kerosene, or engine oil.  

Harman Mark Series Stove

Label measures: 9.5" high X 8.5" wide

OMNI-Test Laboratories, Inc.

Report #/Rapport #135-S-07-4

Tested to/Testé à:

UL 737, UL 1482, June 1985

Meets requirements of ULC S627/

Selon les exigences de ULC S627

Certifi ed for U.S.A. and Canada/Certifi é 

pour les États-Unis et le Canada

BARCODE LABEL

008

Serial No.

N

o

 de série:

CAUTION

: HOT WHILE IN OPERATION. DO NOT TOUCH. 

KEEP  CHILDREN  AND  CLOTHING  AWAY.  CONTACT  MAY 

CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. 

KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS 

A CONSIDERABLE DISTANCE AWAY FROM THIS APPLIANCE.

ATTENTION

:

 CHAUD-NE PAS TOUCHER. TENIR LES 

ENFANTS  ET  LES  VENTEMENTS  A  L’ECART.  RISQUE  DE 

BRULURE. VOIR INSTRUCTIONS SUR LA PLAQUE. LAISSER 

UNE  DISTANCE  SUFFISANTE  ENTRE  L’APPAREIL  ET  LES 

MEUBLESOU AUTRES OBJECT A RISQUE.

LISTED SOLID FUEL (COAL) FIREPLACE STOVE OR ROOM HEATER

POÊLE (DE CHARBON) DANS UN FOYER OU APPAREIL DE CHAUFFAGE

 

PREVENT HOUSE FIRES:

Install  and  use  only  in  accordance  with  manufacturer’s  installation  and  operation  instructions  and 

local building codes. In absence of any local codes, installation must meet minimum requirements of 

NFPA 211 in USA. Refer to manufacturer’s instructions and local codes for precautions required for 

passing chimney through a combustible wall or ceiling. Inspect and clean chimney system frequently 

in accordance with manufacturer’s instructions.

FOR USE WITH COAL ONLY.

Don’t connect this stove to a chimney serving another appliance.

Flue connector pipe must be 6” diameter, minimum 24 MSG black or 26 MSG blue steel.

Chimney must be factory built 103HT or masonry.

NOTE: Replace glass only with 5mm ceramic glass available from your dealer.

Inspect and clean chimney frequently. Under certain condictions of use, creosote buildup may occur 

rapidly.

DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS, YOU ARE OVERFIRING.

 

MODEL/

Modèle:

MARK I

MARK II

MARK III

CONTACT YOUR LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA/

CONTACTEZ LE BUREAU DE LA CONSTRUCTION OU LE BUREAU DES INCENDIES AU DES RESTRICTIONS ET DE L’INSPECTION D’INSTALLATION DANS VOTRE VOISINAGE

 

PR

É

VENTION DES FAUX DE MAISON:

Installez et utilisez en accord avec les instructions d’installation et d’opération du fabricant et des codes 

locaux. S’il n’y a pas de codes lacaux. l’installation doit suivre kes exigences minimum de NFPA 211 

aux É

tats-Unis. Référez vous aux instructions du fabricant et des codes locaux pour les précautions 

pour passer une cheminée à travers un mur ou unplafond combustibles. Inspectez et nettoyez le 

systèm de chiminée fréquemment en accord avec les instructions du fabricant.

UTILISER SEULEMENT DU CHARBON

Ne pas connecter cet appareil à un tuyau de cheminée servant un autre appareil.

Le tuyau connector doit être de 6” de diamètre, d’acier noir de minimum de 24 MSG ou d’acier bleu 

de 26 MSG.

La cheminée doit être bâtit à l’usine de 103 HT ou faite en briques.

Note:  Remplacez  la  vitre  seulement  avec  une  vitre  céramique  de  5mm  disponible  chez  votre 

fournisseur. 

Inspectez et nettoyez la cheminée fréquemment. Sous certaines conditions. il se peut que la créosote 

s’accumule rapidement.

NE  PAS  SURCHAUFFER.  SI  L’APPAREIL  DE  CHAUFFAGE  OU  LE  TUYAU  DE  CHEMIN

É

ROUGISSENT. VOUS SURCHAUFFEZ.

CLEARANCE TO COMBUSTIBLE SURFACE

A - Unit to Sidewall 

          33”

B - Unit to Backwall 

          24”

C - Chimney Connector to Side Wall     42”

D - Chimney Connector to Back Wall    18”

E - Floor Protector, Side and Rear          8”

F - Floor Protector, Front 

          16”

H - Pipe conector to Ceiling 

          18”*

*Not Tested - NFPA Guildlines

ESPACES LIBRES AUX COMBUSTIBLES
A - Du mur de côté à l’appareil                   33”

B - Du mur arrière àl’appareil                   24”

C - Du tuyau de cheminée au mur de côté   42”

D - Du tuyau de cheminée au mur arrière    18”

E - Du plancher protecteur, Côté arrière        8”

F - du plancher protecteur, Devant               16”

H - Du tuyau connecteur au plafond             18”*

*Pas testé - indications NFPA

Floor protection must be a 3/8” min. thickness, 

non-combustible material or equivalent, extending 

beneath heater and to front/sides/rear as indicated 

on the diagram

Leprotecteur de plancher doit être de 3/8” 

d’épaisseur minimum, fait de matière non 

combustible ou équivalent, s’étendant en dessous, 

en avant, en arrière et sur les côtés de l’appareil de 

chauffage comme indiqué sur le diagramme.

ELECTRICAL RATING: 115VAC, 60 HZ, 1.1 AMPS

DANGER: Risk of electrical shock. Disconnect power supply before servicing. Route power cord away from unit.

Do not route power cord under or in front of appliance.

PUISSANCE ÉLECTRIQUE: 115VAC, 60 HZ, 1.1 AMPS

DANGER: Il y a risque de choque électrique. Déconnectez le fi l électrique avant le service

É

loignez le fi l électrique de l’appareil. Ne placez pas le fi l électrique sous ou à l’avant de l’appareil.

CAUTION: 

RISK OF EXCESSIVE TEMPERATURE AND DAMAGE TO UNIT.

PROPER OPERATION REQUIRES THE USE OF ONLY PEA, NUT & COAL STOVE SIZE 

ANTHRACITE COAL

ATTENTION: 

IL  Y  A  RISQUE  DE  TEMPÉRATURES  EXCESSIVE  ET  DE  DOMMAGE  À 

L’APPAREIL. UN BON FONCTIONNEMENT EXIGE L’USAGE D’ANTHRACITE DE CHARBON DE 

GROSSEUR D’UN POIS, D’UNE NOIX OU D’UN CHARBON.

Manufactured by/Fabriqué par:

Harman Home Heating

352 Mountain House Road

Halifax, Pa 17032

2012   2013   2014   JAN   FEB   MAR   APR   MAY   JUN   JUL   AUG   SEP   OCT   NOV   DEC

Exempt From EPA Certifi cation under 40 CFR 60.531

Date of Manufacture / Date de fabrication

Rev B

P.N. 3-90-90736

BACKWALL

SIDE

W

ALL

A

C

B

D

STOVE

H

D

B

Please copy your serial number, 

from  the  label  on  the  back  of 

your stove, to the box below.

THis appliance is also approved for installation into a shop.

Listed by: OMNI-Test Laboratories, INC

Report # 135-S-07-4

Содержание Magnafire MARK I

Страница 1: ...HORITY SUCH AS THE MUNICIPAL BUILDING DEPARTMENT FIRE DEPARTMENT FIRE PREVENTION BUREAU ETC TO DETERMINE THE NEED FOR A PERMIT CETTE GUIDE D UTILISATION EST DISPONIBLE EN FRANCAIS CHEZ VOTRE CONCESSIO...

Страница 2: ...3 90 70746R11_06 13...

Страница 3: ...S ET DE L INSPECTION D INSTALLATION DANS VOTRE VOISINAGE PR VENTION DES FAUX DE MAISON Installez et utilisez en accord avec les instructions d installation et d op ration du fabricant et des codes loc...

Страница 4: ...2 3 Assembly 2 4 General Information 3 Venting 3 1 Types of Chimneys 3 2 Common Chimney Problems 3 3 What To Do If You Have A Problem 3 4 Chimney Details 4 Grates 4 1 Grate System and Controls 5 Oper...

Страница 5: ...ease the amount of fresh air in the room during this initial break in period This may be achieved by opening doors or windows 1 4 Mobile Homes This stove is not approved for use in mobile manufactured...

Страница 6: ...ctor pipe Position the stove as close to the flue as possible 8 ft or less No more than two 90 elbow fittings should be used Any horizontal connector pipe should have at least 1 4 in of rise per foot...

Страница 7: ...umn WC To measure the draft drill a hole in the connector pipe and attach a draft meter First check the draft above the barometric damper if installed Then check it below the barometric damper and mak...

Страница 8: ...oxygen getting to the fire E Remember open the draft control and crack the door open slightly before reloading or checking the fire F Check the ashes The ash pan and firebox may be overloaded with as...

Страница 9: ...al bed should be bright and vigorous If the fire is burning hot and there is a deep bed of hot coals full loads of coal can be added at any time However if there is not a deep bed of coals it is best...

Страница 10: ...blower and clean the fan If there are pets in your house you may want to check this more frequently Grates Keep ash pan emptied Twice a day Chimney and connector Avoid chimney fires On a regular sche...

Страница 11: ...Magnafire Series Coal Stoves 11 3 90 70746R11_06 13 Optional Water Coil 7 Optional Hot Water Coil Plumbing Diagrams Inside Nut Stove Body Packing Outside Nut Washer...

Страница 12: ...e higher than the top leg of the coil The tank should be elevated if necessary to allow for proper thermo siphon action the method by which water will circulate automatically through the system Circul...

Страница 13: ...ty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty...

Страница 14: ...y does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw...

Страница 15: ...available 3 00 00038 4 Rect Glass 7 1 4 X 10 1 2 3 40 7251050 Y 3 Spring Handle 1 2 Pkg of 3 3 40 00086 3 3 4 Short Shaker Handle Weldment 1 10 01001 Y 5 Ash Door Roped 1 10 08143A Draft Control Cast...

Страница 16: ...00 900450125 Y 414 Pcs 3 40 900450 414 brick Angles Qty 2 req 2 00 01100 2S brick bracket 2 00 01006 brick Set 1 00 00836 Y Door Handle Cast 4 00 00042 Y Door Hinge Qty 4 req 2 00 07203D Door Latch 4...

Страница 17: ...0 8501494 Y Rect Glass 4 1 2 X 8 1 2 Triple Frame 3 40 450850 Y 3 Spring Handle 1 2 Pkg of 3 3 40 00086 3 3 4 Short Shaker Handle Weldment 1 10 01001 Y 5 Ash Door Cast 4 00 00213D Y Draft Control Cast...

Страница 18: ...42 Y Door Hinge Qty 4 req 2 00 07203D Door Latch 4 Sets 1 00 00036 Y Door Pin 3 8 x 2 1 4 Load Door Pkg of 4 4 30 00138A Y Gasket 1 2 Round Rope Load Door Ash Door 20 Ft 1 00 53500 Y Gasket Glue 32 oz...

Страница 19: ...Control Cast 4 00 00109 1 Draft Control Gold No longer available 3 00 00109 4 Additional service parts on following page 11 12 Magnafire Freestanding Coal Stove 1 70 03227 1 Black Ending Manufacturing...

Страница 20: ...Set of cut 1 00 00838 Y brick bracket 2 00 01006 Door Handle Cast 4 00 00042 Y Door Hinge Qty 4 req 2 00 07203D Door Latch 4 Sets 1 00 00036 Y Door Pin 3 8 x 1 7 8 Ash Pan Pkg of 4 4 30 00138b Y Door...

Страница 21: ...Magnafire Series Coal Stoves 21 3 90 70746R11_06 13 Service Maintenance Log Date Of Service Performed By Description Of Service...

Страница 22: ...Magnafire Series Coal Stoves 22 3 90 70746R11_06 13 Service Maintenance Log Date Of Service Performed By Description Of Service...

Страница 23: ...3 90 70746R11_06 13...

Страница 24: ...inted On 100 Recycled Paper At Harman we build each product to a standard not a price Signature of Boxer Your premium quality hearth product designed and assembled by the experienced and skilled membe...

Отзывы: