background image

5

3-90-70745R16_08/13

2. 

Positive connect method;

 Similarly, this method employs 

the  use  of  a  stainless  steel  liner,  however  the  liner  is 

run the entire length of the chimney. It is not necessary 

to seal around the venting at the damper, however the 

proper flashing must be used at the top of the chimney to 

ensure that rain and  

other elements do not 

enter the chimney.

An oval to round transition 

such as Simpson Dura-

Vent®  Item  #6DLO-

36FR  works  well  for 

passing  through  the 

narrow damper area. In 

some cases, this piece 

which is 36 inches long 

will  reach  the  first  flue 

tile. If more connector is 

needed, or for a full liner 

installation,  it  provides 

the anchor point for 6inch 

dura-liner® to be used.

See more on chimney requirements later in this manual.   

With the liner or connector inserted into the chimney, install 

the flue adapter to the pipe using a minimum of three screws. 

Position the adapter at a height  of  just under 24 inches from 

the floor of the fireplace. (See Fig. B).

2.1  PArTS INSPECTION

Upon receipt of your Harman® Insert, please be sure you 

have all of the pieces. You should find the following:

1.  Ash Pan

2.  Shaker Handle

3.  Manual and Warranty

4.  Steel Flue Plate (see illustration in section 2.2)

5.  Door Kit - Separate carton 

a.  Glass Frame

b.  Glass,  Door  Top  Trim,  Draft  Control,  (3)  Spring  

handles, And Hardware Pack.

6.  Wing Kit - 2 separate cartons

a. Top Wing and Brass Trim

b. Side Wings with Blowers, Power Cord, and a package 

containing the blower box covers and hardware.

2.2  INSTAllATION INSTruCTIONS

The  minimum fireplace size that your Harman® Insert will 

fit into is  24" high by 31" wide.  A critical dimension for fit in 

the fireplace is that you must have 16 1/8" depth minimum 

at 24" height minimum.  

The first step in installing your new insert is to locate the 

damper in the top of the fireplace. At a minimum, the damper 

must be secured in the open position with wire or other non-

combustible material. If possible, it is best to totally remove 

the damper to prevent accidental closing. 

Before proceeding with installation, it is recommended that you 

have your chimney cleaned and inspected by a professional 

to determine that your chimney is in safe condition.  

IT IS YOur rESPONSIbIlITY TO mAKE CErTAIN YOur 

ChImNEY IS IN ThE PrOPEr  CONdITION TO SAFElY 

FuNCTION wITh A SOlId FuEl burNINg APPlIANCE.  

IT IS AlSO YOur rESPONSIbIlITY TO COmPlY wITh 

All STATE ANd lOCAl COdES PErTAININg TO 

INSTAllATION ANd burNINg OF SOlId FuElS.

There are two acceptable means for connecting the exhaust 

of the insert to the chimney. 

1. 

direct connect method;

 This method employs a short 

section of stainless steel flex pipe which attaches to the 

insert and runs through the damper and into the chimney 

base. This must be run at least as high as the first flue 

tile. The chimney must be sealed around the flex pipe. 

this is usually best accomplished with a steel plate or non-

combustible packing material around the original damper 

location.

 ASSEmblY & INSTAllATION

Stainless Steel 

Flex Pipe

Flue Adapter

Attach with At 

least 3 Screws

Figure A

Flue Adapter 

guide handle

block-Off Plate

Tile Flue liner

Figure B

Approximately 24" 

height From Floor

Содержание Magnafire Elite Coal

Страница 1: ...ing department fire department fire prevention bureau etc to determine the need for a permit Cette guide d utilisation est disponible en francais Chez votre concessionnaire de Harman home heating save these instructions Installation Operating Manual Model s Magnafire Elite Coal Fireplace Insert NOTICE SAVE THESE INSTRUCTIONS Hot glass will cause burns Do not touch glass until it is cooled NEVER al...

Страница 2: ......

Страница 3: ...s 8 Wiring Diagram 10 Grate System 11 Warnings Special Instructions 11 Operation Maintenance 12 Warranty 15 Service Maintenance Log 17 Manufactured By a Division of Hearth and Home Technolgies 352 Mountain House Road Halifax PA 17032 www harmanstoves com Contains updated information ...

Страница 4: ... of a Magnetic Temperature Gauge to monitor the Insert temperatures relative to the amount of draft at which the customer permits the stove to operate It has been verified that creosote will ignite at 650 degrees Fahrenheit It is the owner s responsibility to follow these recommendations This insert consumes air when it is burning It is advisable that a window in the vicinity be opened slightly wh...

Страница 5: ...dware 2 2 INSTALLATION INSTRUCTIONS The minimum fireplace size that your Harman Insert will fit into is 24 high by 31 wide A critical dimension for fit in the fireplace is that you must have 16 1 8 depth minimum at 24 height minimum The first step in installing your new insert is to locate the damper in the top of the fireplace At a minimum the damper must be secured in the open position with wire...

Страница 6: ...ntered to allow for easier hole location Next usingthecornerclipsprovidedinthehardwarepackage install the brass trim onto the lid Place the lid onto the blower box and slip the flat head screw downward through the lid and tighten it into the retainer Repeat for both sides Next slide the insert into the fireplace making sure that the front tab of the flue adapter is resting on top of the insert Thi...

Страница 7: ...ay the glass into the frame Now lift the load door off of the stove and lay it down onto the glass frame Secure the frame to the door using 4 Flange head bolts provided While the door is still laying flat install the top trim onto the door with 2 Hex head bolts Thecoilspringhandlesslipontothelatchesandtheshaker handle Push while turning to install ASSEMBLY INSTALLATION Grates Grate Link Shaker Bar...

Страница 8: ...he chimney D Trees or Other Topographical Barriers Impeding the chimney s operation or causing a down draft condition to exist This can also be caused by adjacent buildings or the roof of the same structure where the chimney is not high enough See Fig H NOTE THE CHIMNEY ON THE HOUSE ILLUSTRATED IS TOO LOW IT SHOULD BE RAISED TO COMPENSATE FOR DRAFTS E ChimneySize Chimneyisnotproperlysizedtoadequat...

Страница 9: ...othechimney they may be causing draft problems This must be corrected by your heating contractor 3 4 CHIMNEY DETAILS Chimney Liners Most of the customer inquiries received are problems caused by poor or in some cases excessive draft A result of poor draft could be creosote back puffing and smoky firebox when loading Indications of excessive draft are burning too much fuel and high stack temperatur...

Страница 10: ...lectric power at fuse box or circuit breaker panel before making any line voltage connections Follow local electrical codes Be sure to route power so that it doesn t come in contact with the stove IMPORTANT ALL WIRING SHOULD BE DONE IN ACCORDANCE WITH LOCAL AND STATE CODES ...

Страница 11: ...t these levels for extended periods of time can damage internal parts of the insert Inserts unlike free standing stoves have no way to release built up heat into your home except through its internal passages Free standing stoves radiate their heat freely into the air Use of the blowers is not only critical to the life of the insert but much heat efficiency is lost if the design of the system is d...

Страница 12: ...en the loading door an inch or two for a few seconds before opening completely This method will allow smoke to clear away from thedooropeningbeforetheloadingdooriscompletelyopened Add small compact pieces of hardwood when the kindling is burninghot Keepthedraftcontrolsfullyopentoestablishahot fire quickly The ash door also may be opened during start up to accelarate the intial burn but must be clo...

Страница 13: ...OULD BE REDUCED GRATES DAMAGED IN THIS WAY ARE EASILY RECOGNIZED BY THE EXTREME DAMAGE CAUSED TO THE GRATES PLEASE REFER TO YOUR WARRANTY TO SEE THE LIMITSOFLIABILITYINCASESOFABUSEORNEGLECT 8 3 INCREASING HEAT FROM A LOW FIRE Every effort should be made not to let a coal fire burn too long so that the fire has started to die This will cause the reloading process to be much longer and there is a go...

Страница 14: ... NOTE ASTOVESHOULDNEVERBELEFTUNATTENDED WITH THE ASH DOOR OPEN WITH THE EXCEPTION OF THE START UP PERIOD THE ASH PAN DOOR SHOULD NEVER BE LEFT OPEN Seriousdamagetothestovecanoccurfromoverheating Coal stoves should not be installed in any chimney that has hadahistoryofback draftingorflowreversal Theseconditions can cause improper draft resulting in carbon monoxide entering the house rather than bei...

Страница 15: ...me construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor fo...

Страница 16: ...ty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plat...

Страница 17: ...17 3 90 70745R16_08 13 Service Maintenance Log Date Of Service Performed By Description Of Service ...

Страница 18: ...18 3 90 70745R16_08 13 Service Maintenance Log Date Of Service Performed By Description Of Service ...

Страница 19: ...19 3 90 70745R16_08 13 ...

Страница 20: ...100 Recycled Paper At Harman we build each product to a standard not a price Signature of Boxer Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax PA USA ...