background image

11

3-90-70745R16_08/13

Section  5
5.1 grATE SYSTEm

A.

 

heavy-duty cast iron grate system

 - The functions of a 

grate system are to support the coal and at the same time 

provide  air  flow  through  the  grates  to  the  coal.  Harman® 

grates have a maximum amount of air flow to produce an 

even burning fire. Another function is to remove the ash from 

the coal bed by grinding, breaking, or shaking them through 

the grates. Harman® grates provide a variable amount of 

grinding action, this action is controlled by the movement 

of a long shaker lever located on the left side of the stove.

b. burns three sizes of anthracite coal

 - You can burn pea, 

nut, or stove coal on these grates with no changes necessary.

C. warnings

1. ImPOrTANT! 

When shaking is complete, turn the shaker 

until the grates are flat and horizontal.

2. Keep the ash drawer empty! 

Ash buildup can damage 

your grates. If ash builds under and against the grates, it will 

cause the air flow to be stopped or lessened. This condition 

will cause warping of the grates.

NOTE:  grates damaged in this way are easily detected by 

the great amount of damage caused to them. Please read 

your warranty to see limits of liability in cases of abuse.
3. Fresh ashes are hot! 

Never put hot ashes in contact with 

any flammable material. Store hot ashes in a metal container 

outside of your home. Allow the ashes to cool then dispose 

of properly.

grATES & wArNINgS

Section 6:
wArNINgS & SPECIAl INSTruCTIONS
6.1 blower: 

Your Harman® insert is provided with a blower system. This 

system  is  not  only  designed  to  distribute  heat  throughout 

your home but serves a critical need in the design system 

of the insert. Extremely high heats are generated inside the 

insert and can do much damage to the heat exchanger and 

baffle system. Surface temperatures of 500 degrees F. can be 

associated with internal temperatures as high as 1000 degrees 

F. or more. Temperatures at these levels for extended periods 

of time, can damage internal parts of the insert. Inserts, unlike 

free standing stoves, have no way to release built up heat 

into your home except through its internal passages. Free 

standing stoves radiate their heat freely into the air.
Use of the blowers is not only critical to the life of the insert, 

but much heat efficiency is lost if the design of the system is 

defeated by not using the blowers. The heat which is trapped 

in the fireplace may amount to as much as 75% of the total 

output of the insert. This should make it easy to see that fuel 

is being wasted if the blowers are not used.   
Harman® has gone to great lengths to design this insert to 

have the best balance of features, looks, and price available 

in the market place today. We also stand strongly behind 

our warranty as long as the warranty claim falls within the 

stated liability of that warranty. Abuse and neglect are terms 

outside the liability of Hearth & Home Technologies in matters 

of  warranty  repair  or  replacement.  To  clarify,  overfiring  is 

considered abuse and will not be eligible for warranty repair. 

Non-use of the blower system is one of the major causes of 

overfiring in insert use. An overfire situation is considered 

to exist when the surface temperature of the insert exceeds 

500 degrees F..

6.2 

NOTE: It is your responsibility to follow all state and local 

codes when installing your insert.

6.3 

It is suggested that you have a qualified stove installer 

install your insert.

6.4

 It is your responsibility to make sure that proper clearances 

to combustible materials is maintained when installing your 

insert.

NOTE:  

Safe clearance to combustibles is 36 inches. If you 

have a flammable mantel and proper clearance cannot be 

maintained, a metal shield must be installed to protect the 

mantel.

6.5

 Have your fireplace and chimney inspected by a qualified 

chimney sweep to make sure your fireplace and chimney are 

safe and in good operating condition.

6.6

 Make sure your chimney has an adequate draft of 0.06 

inches of water column on a draft meter.

Содержание Magnafire Elite Coal

Страница 1: ...ing department fire department fire prevention bureau etc to determine the need for a permit Cette guide d utilisation est disponible en francais Chez votre concessionnaire de Harman home heating save these instructions Installation Operating Manual Model s Magnafire Elite Coal Fireplace Insert NOTICE SAVE THESE INSTRUCTIONS Hot glass will cause burns Do not touch glass until it is cooled NEVER al...

Страница 2: ......

Страница 3: ...s 8 Wiring Diagram 10 Grate System 11 Warnings Special Instructions 11 Operation Maintenance 12 Warranty 15 Service Maintenance Log 17 Manufactured By a Division of Hearth and Home Technolgies 352 Mountain House Road Halifax PA 17032 www harmanstoves com Contains updated information ...

Страница 4: ... of a Magnetic Temperature Gauge to monitor the Insert temperatures relative to the amount of draft at which the customer permits the stove to operate It has been verified that creosote will ignite at 650 degrees Fahrenheit It is the owner s responsibility to follow these recommendations This insert consumes air when it is burning It is advisable that a window in the vicinity be opened slightly wh...

Страница 5: ...dware 2 2 INSTALLATION INSTRUCTIONS The minimum fireplace size that your Harman Insert will fit into is 24 high by 31 wide A critical dimension for fit in the fireplace is that you must have 16 1 8 depth minimum at 24 height minimum The first step in installing your new insert is to locate the damper in the top of the fireplace At a minimum the damper must be secured in the open position with wire...

Страница 6: ...ntered to allow for easier hole location Next usingthecornerclipsprovidedinthehardwarepackage install the brass trim onto the lid Place the lid onto the blower box and slip the flat head screw downward through the lid and tighten it into the retainer Repeat for both sides Next slide the insert into the fireplace making sure that the front tab of the flue adapter is resting on top of the insert Thi...

Страница 7: ...ay the glass into the frame Now lift the load door off of the stove and lay it down onto the glass frame Secure the frame to the door using 4 Flange head bolts provided While the door is still laying flat install the top trim onto the door with 2 Hex head bolts Thecoilspringhandlesslipontothelatchesandtheshaker handle Push while turning to install ASSEMBLY INSTALLATION Grates Grate Link Shaker Bar...

Страница 8: ...he chimney D Trees or Other Topographical Barriers Impeding the chimney s operation or causing a down draft condition to exist This can also be caused by adjacent buildings or the roof of the same structure where the chimney is not high enough See Fig H NOTE THE CHIMNEY ON THE HOUSE ILLUSTRATED IS TOO LOW IT SHOULD BE RAISED TO COMPENSATE FOR DRAFTS E ChimneySize Chimneyisnotproperlysizedtoadequat...

Страница 9: ...othechimney they may be causing draft problems This must be corrected by your heating contractor 3 4 CHIMNEY DETAILS Chimney Liners Most of the customer inquiries received are problems caused by poor or in some cases excessive draft A result of poor draft could be creosote back puffing and smoky firebox when loading Indications of excessive draft are burning too much fuel and high stack temperatur...

Страница 10: ...lectric power at fuse box or circuit breaker panel before making any line voltage connections Follow local electrical codes Be sure to route power so that it doesn t come in contact with the stove IMPORTANT ALL WIRING SHOULD BE DONE IN ACCORDANCE WITH LOCAL AND STATE CODES ...

Страница 11: ...t these levels for extended periods of time can damage internal parts of the insert Inserts unlike free standing stoves have no way to release built up heat into your home except through its internal passages Free standing stoves radiate their heat freely into the air Use of the blowers is not only critical to the life of the insert but much heat efficiency is lost if the design of the system is d...

Страница 12: ...en the loading door an inch or two for a few seconds before opening completely This method will allow smoke to clear away from thedooropeningbeforetheloadingdooriscompletelyopened Add small compact pieces of hardwood when the kindling is burninghot Keepthedraftcontrolsfullyopentoestablishahot fire quickly The ash door also may be opened during start up to accelarate the intial burn but must be clo...

Страница 13: ...OULD BE REDUCED GRATES DAMAGED IN THIS WAY ARE EASILY RECOGNIZED BY THE EXTREME DAMAGE CAUSED TO THE GRATES PLEASE REFER TO YOUR WARRANTY TO SEE THE LIMITSOFLIABILITYINCASESOFABUSEORNEGLECT 8 3 INCREASING HEAT FROM A LOW FIRE Every effort should be made not to let a coal fire burn too long so that the fire has started to die This will cause the reloading process to be much longer and there is a go...

Страница 14: ... NOTE ASTOVESHOULDNEVERBELEFTUNATTENDED WITH THE ASH DOOR OPEN WITH THE EXCEPTION OF THE START UP PERIOD THE ASH PAN DOOR SHOULD NEVER BE LEFT OPEN Seriousdamagetothestovecanoccurfromoverheating Coal stoves should not be installed in any chimney that has hadahistoryofback draftingorflowreversal Theseconditions can cause improper draft resulting in carbon monoxide entering the house rather than bei...

Страница 15: ...me construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty period for parts and labor fo...

Страница 16: ...ty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and residues left on the plat...

Страница 17: ...17 3 90 70745R16_08 13 Service Maintenance Log Date Of Service Performed By Description Of Service ...

Страница 18: ...18 3 90 70745R16_08 13 Service Maintenance Log Date Of Service Performed By Description Of Service ...

Страница 19: ...19 3 90 70745R16_08 13 ...

Страница 20: ...100 Recycled Paper At Harman we build each product to a standard not a price Signature of Boxer Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax PA USA ...

Отзывы: