1
ESP CONTROL
Feed Adjuster
Sets the maximum feed
rate, 1 to 5
Test
Runs all motors at
full speed for two
minutes to check
operation. After two
minutes the stove
will go to minimum
burn and the blowers
will alternate from
high to low every two
minutes to remind
you that you are still
in "Test Mode".
Distribution Blower
speed adjustment range.
2 Blinks:
Indicates that the negative pressure in the fire
-
box has been too low for at least 68 seconds. This begins
a three stage shut-down process described in detail on
Page 30.
The most common cause of the 2 blink status is leaving
the ash door open for more than 3 to 5 minutes without
turning the Feed Adjuster to "Ash Out". For other causes
of a 2 blink status see Page 30.
This requires a Manual Reset*.
3 Blinks:
Indicates that the ESP (Exhaust Sensing Probe)
has gone out of range a specified number of times. If
the stove seems to be performing normally, perform a
Manual Reset*.
4 Blinks:
Can occur only in Room Temp Mode and indi-
cates Room Sensing Probe has failed or is not installed.
If a Room Sensing Probe is then installed, the status light
will automatically reset.
5 Blinks:
Indicates a lack of communication between the
circuit board and the TCP (Temperature Control Probe).
This requires a manual reset*.
* Manual Reset:
Disconnect power cord for a few seconds
and reconnect. If error still occurs call your Dealer.
Temp Dial
Allows you to adjust the room temperature
in Room Temp Mode using the outer scale
marked in degrees Fahrenheit. It also allows
you to adjust the stove temperature while
in Stove Temp Mode using the inner scale
marked from 1 to 7.
Mode Selector
Allows you to choose between Room Temp
Mode, Stove Temp Mode, or OFF. Also
allows you to vary the Distribution Blower
speed by turning the knob to the "high" or
"low" side of each mode.
Power Light
Indicates power is "on" to
the control.
Indicates power to
Distribution Blower
Indicates power to the
Feed Motor.
Indicates power to
Combustion Blower
Status Light
Will be lit in either Stove
or Room Temp Mode when
pointer is not within "off"
position band except after
normal shut down. Blinks
to indicate errors listed
below.
Ash Removal position
See page 19
Operation
Indicates power to the
Draft Motor.
Status Light Error Messages:
fig. 12
Содержание DVC-500
Страница 2: ...This appliance is also approved for installation into a shop...
Страница 10: ...10 Installation...
Страница 12: ...12 Installation...
Страница 13: ...13 Installation...
Страница 16: ...16 ESP Control Hopper Lid Latch Ash Door Latch Handle Glass Door Latch Handle Side Panel Latch...
Страница 26: ...26 Wiring Diagram...
Страница 32: ...32...
Страница 33: ...33...
Страница 34: ...34 Service Maintenance Log Date Of Service Performed By Description Of Service...
Страница 35: ...35 Service Maintenance Log Date Of Service Performed By Description Of Service...
Страница 36: ......