Harman DBX 1066 Скачать руководство пользователя страница 5

2

Introduction

Introduction

Congratulations and thank you for your purchase of the dbx 1066 Compressor. The dbx 1066 is a high perfor-
mance multifunctional unit designed to deliver all the flexibility and power that a professional user demands. 
The dbx 1066 incorporates the new advanced dbx V2™ VCA for high system performance. We recommend you 
take a moment to read through this Operation manual. It provides information that will assist you in system 
set-up. 

Inspection

Verify that the 1066’s package contains the following:

s5NITACCORDINGTO-ODELNUMBERMARKEDONPACKAGE 

s!#0OWER#ORD

s/PERATION-ANUAL

s2EGISTRATION#ARD

s2ACK-OUNT3CREWSAND7ASHERS

)FANYOFTHESEITEMSAREMISSINGCONTACTDBXCUSTOMERSERVICEAT 

Warranty

1.  The warranty registration card that accompanies this product must be mailed within 30 days after purchase 

DATETOVALIDATETHISWARRANTY0ROOFOFPURCHASEISCONSIDEREDTOBETHEBURDENOFTHECONSUMER

DBXWARRANTSTHISPRODUCTWHENBOUGHTANDUSEDSOLELYWITHINTHE53TOBEFREEFROMDEFECTSINMATERIALS

and workmanship under normal use and service. 

3.  dbx liability under this warranty is limited to repairing or, at our discretion, replacing defective materials 

THATSHOWEVIDENCEOFDEFECTPROVIDEDTHEPRODUCTISRETURNEDTODBX7)4(2%452.!54(/2):!4)/.FROMTHE
FACTORYWHEREALLPARTSANDLABORWILLBECOVEREDUPTOAPERIODOFTWOYEARS!2ETURN!UTHORIZATIONNUMBER

must be obtained from dbx by telephone. The company shall not be liable for any consequential damage as a 
result of the product’s use in any circuit or assembly.

DBXRESERVESTHERIGHTTOMAKECHANGESINDESIGNORMAKEADDITIONSTOORIMPROVEMENTSUPONTHISPRODUCT

without incurring any obligation to install the same additions or improvements on products previously manu-
factured.

4HEFOREGOINGISINLIEUOFALLOTHERWARRANTIESEXPRESSEDORIMPLIEDANDDBXNEITHERASSUMESNORAUTHORIZES

any person to assume on its behalf any obligation or liability in connection with the sale of this product. In 
no event shall dbx or its dealers be liable for special or consequential damages or from any delay in the per-

formance of this warranty due to causes beyond their control.

Содержание DBX 1066

Страница 1: ...MODEL 1066 Operation Manual...

Страница 2: ...nt only to the power source indicated on the equipment rear panel To reduce the risk of re or electric shock refer servic ing to quali ed service personnel or equivalent If connected to 240V supply a...

Страница 3: ...r to a retailer if you purchase a similar new one For Countries not mentioned above please contact your local authorities for a correct method of disposal By doing so you will ensure that your dispose...

Страница 4: ...1 Contents Introduction 2 Inspection 2 Warranty 2 Connecting the 1066 to your system 3 Operating Controls 4 Applications 9 Installation Considerations 13 Specifications 15 Manual Contents...

Страница 5: ...Y WITHIN THE 5 3 TO BE FREE FROM DEFECTS IN MATERIALS and workmanship under normal use and service 3 dbx liability under this warranty is limited to repairing or at our discretion replacing defective...

Страница 6: ...AND SHOULD BE AVOIDED s AKE AUDIO CONNECTIONS VIA 8 2 v 423 OR v 43 PLUGS Both types of connectors for the inputs and outputs can be used for balanced or unbalanced connec tions The use of more than...

Страница 7: ...E SWITCH WILL LIGHT TO INDICATE THAT THE IS IN THE 3TEREO INK MODE XPANDER ATE 4HRESHOLD ONTROL This control sets the level below which gating expansion occurs It has an EFFECTIVE CONTROL RANGE OF D T...

Страница 8: ...HIS INDICATES THAT THE COMPRESSOR IS NOT COMPRESSING AND IS OPERATING IN ITS linear region OMPRESSOR 4HRESHOLD VER ASY 4HIS ILLUMINATES WHEN THE SIGNAL IS IN THE VER ASY PORTION OF the compression cur...

Страница 9: ...cy de emphasis into the detector path This is extremely USEFUL IN KEEPING LOW FREQUENCY PROGRAM MATERIAL FROM hMUFFLINGv OR hPUNCHING HOLES INv THE COMPRESSED SIGNAL This feature allows faster attack...

Страница 10: ...THE COMPRESSOR T CAN BE CONTINUOUSLY ADJUSTED BETWEEN D AND D 5SE THIS CONTROL TO COMPENSATE FOR SIGNAL LEVEL LOSS DUE TO COMPRESSION AND TO ADJUST THE NOMINAL OUTPUT LEVEL OF THE UNIT YPASS 3WITCH 4H...

Страница 11: ...AM LIMITER QUICKLY ATTENUATES THE INPUT SIGNAL TO A LEVEL SAFELY BELOW THE CLAMPING LEVEL TYPICALLY D LOWER THAN THE CLAMPING LEVEL 4HE 0EAK3TOP0LUS LEVEL CONTROL IS CALIBRATED TO this lower level so...

Страница 12: ...N UNBALANCED v 43 3 2 452 INPUT Applications ATTENING ICK RUMS AND OMPRESSING THER RUMS Weak flabby kick drums often have too much boom and not enough slap To tighten them up start with THE ADJUSTED F...

Страница 13: ...pression curve and THE ACTUAL 2 4 AND 4 2 3 SETTINGS ARE THE SAME AS THOSE PREVIOUSLY COVERED WITH REFERENCE TO single channels of program material However it will generally be found that large amount...

Страница 14: ...WHICH HAVE MORE DECAY AFTER THE INITIAL TRANSIENT SET THE 2 4 CONTROL LOW ENOUGH to allow the gate to remain open and capture the signal s entire envelope HANGING 3OUND 1UALITY The 1066 s expander ga...

Страница 15: ...s less headroom However gentle tapping of a drumstick or brushing of the cymbal will not be held back Assuming the tom tom is a lower frequency instrument and can be better tolerated by the tape it ha...

Страница 16: ...referenced to ground An unbalanced line is generally a single conductor shielded cable with the center conductor carrying the signal and the shield at ground potential ORMAL ALANCED ONNECTIONS FOR NPU...

Страница 17: ...OM SOURCE DEVICE TO NEXT DEVICE TO NEXT DEVICE FROM SOURCE DEVICE TO NEXT DEVICE FROM SOURCE DEVICE TO NEXT DEVICE TO NEXT DEVICE FROM SOURCE DEVICE FROM SOURCE DEVICE TO NEXT DEVICE TO NEXT DEVICE FR...

Страница 18: ...kHz unity gain 0 0496 typical at 20 dBu 1 kHz unity gain 0 1 any amount of compression up to 40 dB 1 kHz IMD 0 1 SMPTE Interchannel Crosstalk 100 dB 20 Hz to 20 kHz VCA dbx V2 Stereo Coupling True RMS...

Страница 19: ...el Switches the nominal operating level between 10 dBV and 4 dBu simultaneously for both input and output levels Stereo Couple Couples both channels for stereo operation Channel One becomes the master...

Страница 20: ...3OUTH 3ANDY 0KWY 3ANDY 5TAH 0HONE AX MAIL CUSTOMER DBXPRO COM Website www dbxpro com 6 0RINTED IN HINA...

Страница 21: ...ere at the touch of the Auto button Or use the independent Attack and Release controls to tailor the 1066 to your specific needs Unwanted frequencies or mic bleed in the signal path Frequency dependen...

Страница 22: ...unweighted 22 kHz measure ment bandwidth Dynamic Range 118 dB unweighted THD Noise 0 008 typical at 4 dBu 1 kHz unity gain 0 08 typical at 20 dBu 1 kHz unity gain 0 1 any amount of compression up to 4...

Отзывы: