Harman DBX 1066 Скачать руководство пользователя страница 2

WARNING FOR YOUR PROTECTION

READ THE FOLLOWING:

KEEP THESE  INSTRUCTIONS

HEED ALL WARNINGS

FOLLOW ALL  INSTRUCTIONS

THE APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING 
LIQUID AND NO OBJECT FILLED WITHI LIQUID, SUCH AS VASES, SHALL 
BE PLACED ON THE APPARATUS.

CLEAN ONLY WITH A DRY CLOTH.

DO NOT BLOCK ANY OF THE VENTILATION OPENINGS. INSTALL IN AC-
CORDANCE WITH THE  MANUFACTURER’S  INSTRUCTIONS.

DO NOT INSTALL NEAR ANY HEAT SOURCES SUCH AS RADIATORS, 
HEAT REGISTERS, STOVES, OR OTHER APPARATUS (INCLUDING AMPLI-
FIERS) THAT PRODUCE HEAT.

ONLY USE ATTACHMENTS/ACCESSORIES SPECIFIED BY THE MANUFAC-
TURER.

UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN 
UNUSED FOR LONG PERIODS OF TIME.

Do not defeat the safety purpose of the polarized or grounding-type plug.  A 
polarized plug has two blades with one wider than the other.  A grounding 
type plug has two blades and a third grounding prong.  The wide blade or third 
prong are provided for your safety.  If the provided plug does not fit your out-
let, consult an electrician for replacement of the obsolete outlet.

Protect the power cord from being walked on or pinched particularly at plugs, 
convenience receptacles, and the point where they exit from the apparatus.

Use only with the cart stand, tripod bracket, or table specified by the manufac-
ture, or sold with the apparatus.  When a cart is used, use caution when moving 
the cart/apparatus combination to avoid injury from tip-over.

Refer all servicing to qualified service personnel.  Servicing is required when 
the apparatus has been damaged in any way, such as power-supply cord or plug 
is damaged, liquid has been spilled or objects have fallen into the apparatus, the 
apparatus has been exposed to rain or moisture, does not operate normally, or 
has been dropped.

POWER ON/OFF SWITCH: If the equipment has a Power switch, the Power 
switch used in this piece of equipment DOES NOT break the connection from 
the mains.

MAINS DISCONNECT:  The plug shall remain readily operable.  For rack-
mount or installation where plug is not accessible, an all-pole mains switch with 
a contact separation of at least 3 mm in each pole shall be incorporated into 
the electrical installation of the rack or building.

FOR UNITS EQUIPPED WITH EXTERNALLY ACCESSIBLE FUSE RECEP-
TACLE:    Replace fuse with same type and rating only.

MULTIPLE-INPUT VOLTAGE: This equipment may require the use of a different 
line cord, attachment plug, or both, depending on the available power source at 
installation. Connect this equipment only to the power source indicated on the 
equipment rear panel. To reduce the risk of fire or electric shock, refer servic-
ing to qualified service personnel or equivalent.

If connected to 240V supply, a suitable CSA/UL certified power cord shall be 
used for this supply.

SAFETY INSTRUCTIONS 

NOTICE FOR CUSTOMERS IF YOUR UNIT IS EQUIPPED WITH A POWER CORD.

WARNING: THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A 
PROTECTIVE EARTHING CONNECTION.

The cores in the mains lead are coloured in accordance with the following code:

GREEN and YELLOW - Earth        BLUE - Neutral        BROWN - Live

As colours of the cores in the mains lead of this appliance may not correspond with the coloured 
markings identifying the terminals in your plug, proceed as follows:

U

  The core which is coloured green and yellow must be connected to the terminal in the plug 

marked with the letter E, or with the earth symbol, or coloured green, or green and yellow.

U

  The core which is coloured blue must be connected to the terminal marked N or coloured black.

U

  The core which is coloured brown must be connected to the terminal marked L or coloured red.

 
This equipment may require the use of a different line cord, attachment plug, or both, depending 
on the available power source at installation.  If the attachment plug needs to be changed, refer 
servicing to qualified service personnel who should refer to the table below. The green/yellow 
wire shall be connected directly to the units chassis.

CONDUCTOR

WIRE COLOR

Normal

Alt

L

LIVE

BROWN

BLACK

N

NEUTRAL

BLUE

WHITE

E

EARTH GND

GREEN/

YEL

GREEN

WARNING: 

If the ground is defeated, certain fault conditions in the unit or in the system to 

which it is connected can result in full line voltage between chassis and earth ground. Severe 
injury or death can then result if the chassis and earth ground are touched simultaneously.

The symbols shown above are internationally accepted symbols that warn of 
potential hazards with electrical products. The lightning flash with arrowpoint in 
an equilateral triangle means that there are dangerous voltages present within 
the unit. The exclamation point in an equilateral triangle indicates that it is 
necessary for the user to refer to the owner’s manual.

These symbols warn that there are no user serviceable parts inside the unit. 
Do not open the unit. Do not attempt to service the unit yourself. Refer all 
servicing to qualified personnel. Opening the chassis for any reason will void 
the manufacturer’s warranty. Do not get the unit wet. If liquid is spilled on the 
unit, shut it off immediately and take it to a dealer for service.  Disconnect the 
unit during storms to prevent damage.

IMPORTANT SAFETY INFORMATION

Содержание DBX 1066

Страница 1: ...MODEL 1066 Operation Manual...

Страница 2: ...nt only to the power source indicated on the equipment rear panel To reduce the risk of re or electric shock refer servic ing to quali ed service personnel or equivalent If connected to 240V supply a...

Страница 3: ...r to a retailer if you purchase a similar new one For Countries not mentioned above please contact your local authorities for a correct method of disposal By doing so you will ensure that your dispose...

Страница 4: ...1 Contents Introduction 2 Inspection 2 Warranty 2 Connecting the 1066 to your system 3 Operating Controls 4 Applications 9 Installation Considerations 13 Specifications 15 Manual Contents...

Страница 5: ...Y WITHIN THE 5 3 TO BE FREE FROM DEFECTS IN MATERIALS and workmanship under normal use and service 3 dbx liability under this warranty is limited to repairing or at our discretion replacing defective...

Страница 6: ...AND SHOULD BE AVOIDED s AKE AUDIO CONNECTIONS VIA 8 2 v 423 OR v 43 PLUGS Both types of connectors for the inputs and outputs can be used for balanced or unbalanced connec tions The use of more than...

Страница 7: ...E SWITCH WILL LIGHT TO INDICATE THAT THE IS IN THE 3TEREO INK MODE XPANDER ATE 4HRESHOLD ONTROL This control sets the level below which gating expansion occurs It has an EFFECTIVE CONTROL RANGE OF D T...

Страница 8: ...HIS INDICATES THAT THE COMPRESSOR IS NOT COMPRESSING AND IS OPERATING IN ITS linear region OMPRESSOR 4HRESHOLD VER ASY 4HIS ILLUMINATES WHEN THE SIGNAL IS IN THE VER ASY PORTION OF the compression cur...

Страница 9: ...cy de emphasis into the detector path This is extremely USEFUL IN KEEPING LOW FREQUENCY PROGRAM MATERIAL FROM hMUFFLINGv OR hPUNCHING HOLES INv THE COMPRESSED SIGNAL This feature allows faster attack...

Страница 10: ...THE COMPRESSOR T CAN BE CONTINUOUSLY ADJUSTED BETWEEN D AND D 5SE THIS CONTROL TO COMPENSATE FOR SIGNAL LEVEL LOSS DUE TO COMPRESSION AND TO ADJUST THE NOMINAL OUTPUT LEVEL OF THE UNIT YPASS 3WITCH 4H...

Страница 11: ...AM LIMITER QUICKLY ATTENUATES THE INPUT SIGNAL TO A LEVEL SAFELY BELOW THE CLAMPING LEVEL TYPICALLY D LOWER THAN THE CLAMPING LEVEL 4HE 0EAK3TOP0LUS LEVEL CONTROL IS CALIBRATED TO this lower level so...

Страница 12: ...N UNBALANCED v 43 3 2 452 INPUT Applications ATTENING ICK RUMS AND OMPRESSING THER RUMS Weak flabby kick drums often have too much boom and not enough slap To tighten them up start with THE ADJUSTED F...

Страница 13: ...pression curve and THE ACTUAL 2 4 AND 4 2 3 SETTINGS ARE THE SAME AS THOSE PREVIOUSLY COVERED WITH REFERENCE TO single channels of program material However it will generally be found that large amount...

Страница 14: ...WHICH HAVE MORE DECAY AFTER THE INITIAL TRANSIENT SET THE 2 4 CONTROL LOW ENOUGH to allow the gate to remain open and capture the signal s entire envelope HANGING 3OUND 1UALITY The 1066 s expander ga...

Страница 15: ...s less headroom However gentle tapping of a drumstick or brushing of the cymbal will not be held back Assuming the tom tom is a lower frequency instrument and can be better tolerated by the tape it ha...

Страница 16: ...referenced to ground An unbalanced line is generally a single conductor shielded cable with the center conductor carrying the signal and the shield at ground potential ORMAL ALANCED ONNECTIONS FOR NPU...

Страница 17: ...OM SOURCE DEVICE TO NEXT DEVICE TO NEXT DEVICE FROM SOURCE DEVICE TO NEXT DEVICE FROM SOURCE DEVICE TO NEXT DEVICE TO NEXT DEVICE FROM SOURCE DEVICE FROM SOURCE DEVICE TO NEXT DEVICE TO NEXT DEVICE FR...

Страница 18: ...kHz unity gain 0 0496 typical at 20 dBu 1 kHz unity gain 0 1 any amount of compression up to 40 dB 1 kHz IMD 0 1 SMPTE Interchannel Crosstalk 100 dB 20 Hz to 20 kHz VCA dbx V2 Stereo Coupling True RMS...

Страница 19: ...el Switches the nominal operating level between 10 dBV and 4 dBu simultaneously for both input and output levels Stereo Couple Couples both channels for stereo operation Channel One becomes the master...

Страница 20: ...3OUTH 3ANDY 0KWY 3ANDY 5TAH 0HONE AX MAIL CUSTOMER DBXPRO COM Website www dbxpro com 6 0RINTED IN HINA...

Страница 21: ...ere at the touch of the Auto button Or use the independent Attack and Release controls to tailor the 1066 to your specific needs Unwanted frequencies or mic bleed in the signal path Frequency dependen...

Страница 22: ...unweighted 22 kHz measure ment bandwidth Dynamic Range 118 dB unweighted THD Noise 0 008 typical at 4 dBu 1 kHz unity gain 0 08 typical at 20 dBu 1 kHz unity gain 0 1 any amount of compression up to 4...

Отзывы: