Harman Crown DSi 8M Скачать руководство пользователя страница 3

Operation Manual

DSi 8M Cinema System Monitor

page 4

page 5

DSi 8M Cinema System Monitor 

Operation Manual

Table of Contents

             Table of Contents

FCC Compliance Notice  ..................................................... 2
Declaration of Conformity  ................................................... 3

1 Welcome  .............................................. 5

     1.1 Features .................................................................... 5
     1.2 Unpacking  ................................................................ 5

2 Controls, Indicators and Connectors ............... 6
 

          

2.1 Front Panel Controls, Indicators and Connectors ....... 6

     2.2 Rear Panel Controls and Connectors

 �����������������������7

3 Installation  ............................................ 8

     3.1 Materials Required  .................................................... 8
     3.2 Mount the DSi 8M ..................................................... 8
     3.3 Monitor Wiring .......................................................... 8

4 Operation  .............................................. 13

     4.1 Setting Monitor and Bargraph Levels ......................... 13

5 Specifications 

 .............................................................. 13

6 Service ................................................. 14

     6.1 International and Canada Service ............................... 14
     6.2 US Service  ................................................................ 14
           6.2.1 Service at a US Service Center  .......................... 14
           6.2.2 Factory Service  ................................................. 14
           6.2.3 Factory Service Shipping Instructions ................ 14
           6.2.4 Packing Instructions .......................................... 14
           6.2.5 Estimate Approval .............................................. 14
           6.2.6 Payment of Non-Warranty Repairs ..................... 14

7 Warranty

 ........................................................................

15

Product Registration Form ................................................... 17
Factory Service Information Form  ....................................... 19

Please read this entire manual 

before beginning your  

installation.

The Crown

®

 

DSi 8M is a projection booth 

monitor for cinema applications. It has been 
designed for high performance, ease of use and 
years of trouble-free service.
All controls necessary for daily operation of the 
DSi 8M are easily accessible on the front panel. 
8-channel monitoring allows you to monitor 
either the inputs from the cinema processor or 
the power amplifier’s outputs: L,C, R, Ls, Rs, 
Bsl, Bsr, and Sub in any combination.

On the back panel are Phoenix connectors and 
HD-15 connectors for quick connection to 
power amplifiers. Inputs and outputs are 
bal anced. The unit is equipped with an internal 
universal power supply.
No special tools are required for installation. 
The built-in VU meter and test jack give the 
technician immediate information about the 
status of the DSi 8M and all power amplifiers.
Your investment in a DSi-Series product is 
backed by Crown’s Three-Year, No-Fault, Fully 
Transferable Warranty.

1.1 Features

• Compact 2-rack unit
• 8 channels for monitoring processor or 
amplifier inputs
• All inputs and outputs are balanced to 
inter face with new cinema processors
• Input levels for processor and power amps 
can be adjusted independently
• No level jumps when switching between 
pro cessor and amplifiers
• Bargraph display may be calibrated to the 
reference level for your theater; projectionist 
sees auditorium levels instantly
• 25-pin D-sub connectors, plus removable 
terminal blocks and HD-15 connectors for 
quick, hassle-free connections
• Designed to work with bi-amplified sound 
systems to monitor the high- and low-fre quency 
outputs from the left, center and right channels
• Three-Year, No-Fault, Fully Transferable 

Warranty completely protects your investment 

and guarantees its specifications

1.2 Unpacking

Please unpack and inspect your DSi 8M 

Moni tor for any damage that may have occurred 

dur ing transit. If damage is found, notify the 

transportation company immediately. Only you 

can initiate a claim for shipping damage. Crown 

will be happy to help as needed. Save the 

shipping carton as evidence of damage for the 

shipper’s inspection. 
We also recommend that you save all packing 

materials so you will have them if you ever need 

to transport the unit. 

Never ship the unit 

without the factory pack.

1 Welcome

Содержание Crown DSi 8M

Страница 1: ...stallation operation or maintenance The information provided in this manual was deemed accurate as of the publication date However updates to this information may have occurred To obtain the latest ve...

Страница 2: ...LE CHOC LECTRIQUE N ENLEVEZ PAS LES COUVERCLES IL N Y A PAS DES PARTIES SERVICEABLE L INT RIEUR TOUS REPARATIONS DOIT ETRE FAIRE PAR PERSONNEL QUALIFI SEULMENT PARA PREVENIR UN CHOQUE EL CTRICO NO RE...

Страница 3: ...Inputs and outputs are bal anced The unit is equipped with an internal universal power supply No special tools are required for installation The built in VU meter and test jack give the technician im...

Страница 4: ...speaker output for the Left High Left Low Center High Center Low Right High and Right Low channels This connector lets you monitor the output of amplifiers that do not include HD 15 connector options...

Страница 5: ...0 60 Hz will be sufficient Plug the Modular Power Supply into the Bypass Power input and into a power source that matches the Modular Power Supply requirements continued L Biamp C Biamp R Biamp Sw Amp...

Страница 6: ...e available presets In this example the DSi 1000 amplifier is set to the JBL 3632 preset which is a highpass filter for the JBL 3632 MF and HF drivers and a lowpass filter for the JBL 3632 LF drivers...

Страница 7: ...bwoofer channels Input Impedance Processor Inputs 10 k ohms Input Impedance Power Amplifiers Inputs 50 k ohms Power Requirements 100 240V 50 60 Hz 32 watts Chassis Steel Dimensions EIA Standard 19 inc...

Страница 8: ...ushions in place 6 Service 2 Carefully place your product with the product s front panel facing the same direction as arrows indicate 3 Reset center cushion down over top of product s chassis The foam...

Страница 9: ..._______ Zip Code ________________ Country __________________________ E mail address ___________________________________________ Phone include area code ___________________________ Fax ________________...

Страница 10: ...___________________________________________________________________ Other equipment in your system _____________________________________________________________________________________________________...

Страница 11: ......

Отзывы: