AIR SHUTTER ADjUSTMENT
The final step of the installation is to check the flame
pattern, which should resemble the pattern illustrated in the
right column: The flames should be relatively well-defined
and stable. they should be bright yellow with a blue base
where attached to the burner ports, and should not look
orange or sooty.
start the heater according to the directions, and allow the
heater to burn for approximately 15 minutes. The flames
will increase in length and become more yellow in color as
the clarity heats up.
If the flames do not resemble the description above and
the illustration in the right column, the air shutters may
need to be adjusted.
three separate screws—one for each burner—are used to
adjust the flames for a particular installation. Two of them
are accessible through the side access port on the right side
of the stove. the third is accessible from the front when
the control door is open. the screws may become hot to
the touch after prolonged operation. use a glove to avoid
contact if hot. For best results when fine-tuning the flame
picture, initially, leave the middle screw unchanged from
its factory setting. turn the other two screws as needed to
increase or decrease the brightness and length of the flame:
turning counterclockwise will decrease the flame; turning
clockwise will increase the flame.
1. to adjust the rear burner, open the right wing door,
reach through the side access port, and turn the rear screw
to adjust flame (see directions above).
2. To adjust the front burner, first open the control door,
then turn the front screw to adjust flame (see directions
above).
Repeat the procedure as needed until the desired flame
effect is achieved.
Monitoring the Gas Flame
Periodically, the flames of the Clarity Direct Vent Gas
heater should be checked while it is in operation. the
flames should be relatively well-defined and stable. They
should be bright yellow with a blue base where attached
to the burner ports. The flames should not look orange or
sooty. Portions of the logs will glow red when the flames
are properly adjusted.
If you find the flames to be other than that described here,
do not operate the heater. Consult a qualified service person
or your harman dealer for advice.
rear Burner
center burner
Front burner
Air adjustment screws
The properly-burning pilot will
resemble the illustration to the
right.
AIR SHUTTER ADjUSTMENT
The Clarity flame pattern will resemble this when the unit is
burning properly.