background image

7

Rear panel 

AC Mains

 

AC Mains input to the universal switched-mode power supply, operates over a wide 

range of AC input voltages from 100V to 240V, 50/60Hz.

Locate

 

Pressing the Locate switch on the rear of the unit will illuminate the PWR LED on the 

front and identify the device within London Architect. Similarly the switch will illuminate 

if the device is located from within London Architect.

RS232

 

Serial port for connection of external control equipment.

Ethernet

 

The main connection for the proprietary system control network, and for third-party 

Ethernet control.

BLU link

 

The London BLU link is a point-to-point digital audio bus with 256 audio channels at 

48K sample rate or 128 audio channels at 96K sample rate. The BLU-101 allows access 

to channels 1-48 of this bus, at 48K sample rates. The physical connection is made with 

Cat 5e cable from the OUT port of one device to the IN port of another device. The 

devices are connected in a daisy chain fashion continuing with the OUT port of one 

device connected to the IN port of the next device. Redundancy can be provided by 

completing the loop and connecting the OUT port from the last device to the IN port of 

the first device in the chain. All devices connected in the London BLU link chain must be 

configured for the same audio sample rate.

Analogue Input/Output Connections

1

2

4

3

1

2

2

4

1

4

3

3

1

2

4

3

2

1

4

3

CONTROL

ETHERNET

LOCATE

OUTPUTS

INPUTS

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

A

B

C

D

E

RS232

IN

OUT

BLU link

THIS EQUIPMENT MUST BE EARTHED

100-240V ~ 50/60Hz, 50W

MANUFACTURED IN THE USA BY BSS AUDIO

 

There are 12 analogue input connections and 8 analogue output connections. The 

analogue connections are balanced, on Phoenix/Combicon connectors.

AEC 

The BLU-101 has AEC capabilities which enable it to cancel acoustic echo arising 

when sound from a loudspeaker enters a microphone in the same room in a conference 

application.
The BLU-101 contains dedicated AEC processing for up to 12 independent AEC 

algorithms.  The AEC algorithm can be applied to signals coming from the local analog 

inputs or from the digital audio bus. 12 individual AEC references (one per algorithm) 

allow the user to provide a solution for multiple conferencing spaces using a single 

device.

1

2

4

3

1

2

2

4

1

4

3

3

1

2

4

3

2

1

4

3

CONTROL

ETHERNET

LOCATE

OUTPUTS

INPUTS

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

A

B

C

D

E

RS232

IN

OUT

BLU link

THIS EQUIPMENT MUST BE EARTHED

100-240V ~ 50/60Hz, 50W

MANUFACTURED IN THE USA BY BSS AUDIO

Содержание BSS Soundweb London BLU-101

Страница 1: ...1 Soundweb TM London BLU 101 Installation Guide 5033747 B...

Страница 2: ...WARNING FOR YOUR PROTECTION READ THE FOLLOWING KEEP THESE INSTRUCTIONS HEED ALL WARNINGS FOLLOW ALL INSTRUCTIONS The apparatus shall not be exposed to dripping or splashing liquid and no object fille...

Страница 3: ...shielded interconnecting cables SAFETY INSTRUCTIONS Notice For Customers If Your Unit Is Equipped With A Power Cord WARNING THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A PROTECTIVE...

Страница 4: ...STEWART TYPE 28A2029 0A0 near the network socket end This equipment must be earthed It should not be necessary to remove any protective earth or signal cable shield connections to prevent ground loops...

Страница 5: ...The COM LED turns green to indicate a normal linked condition The COM LED blinks green if data is being transferred on the Ethernet or RS232 port The LED turns yellow if a link is established but no...

Страница 6: ...e destination to eliminate ground loop problems This means that the shield S connection on an input is grounded whereas the shield connection on an output is floating although connected via an interna...

Страница 7: ...ded by completing the loop and connecting the OUT port from the last device to the IN port of the first device in the chain All devices connected in the London BLU link chain must be configured for th...

Страница 8: ...Qnet London Architect for a table of resistor values for use with Parameter Presets or source selectors Two common ground connections are provided using the two C connectors to the left of the CONTROL...

Страница 9: ...isolated output which fails safe open circuit if the unit becomes faulty switch 2 wire mode relay LED relay 3600R 1800R 1200R unconnected ladder supply voltage 47kOhm log potentiometer 10K 100kOhm lin...

Страница 10: ...to 20kHz A weighted 108dB unweighted CMRR 75dB at 1kHz Equiv Input Noise EIN 125dBu typ with 150 Ohms source Phantom power 48V nominal selectable per input A D Latency 37 Fs 0 77ms 48k AEC Up to 12 c...

Страница 11: ...Mains Voltage 100 240V AC 50 60Hz Power Consumption 55VA BTU Rating 188 BTU hr Operating Temperature Range 5 41 to 35 95 degrees C degrees F Dimensions HxWxD 1 75 45mm 1U x 19 483mm x 12 5 318mm Weigh...

Страница 12: ...12 BSS Audio 8760 South Sandy Parkway Sandy Utah 84070 801 566 8800 www bssaudio com Printed in Malaysia...