background image

4

Regulatory information

An example of this equipment has been tested and found to comply with the following European 

and international Standards for Electromagnetic Compatibility and Electrical Safety:

Radiated Emissions (EU): 

EN55022:2006

Immunity (EU): 

EN55024:1998

Electrical Safety (EU): 

IEC60065-01 + AMD1

Electrical safety (USA): 

UL60065-06

Mechanical installation

Important user information

Do not remove covers. No user serviceable parts inside, refer servicing to qualified service 

personnel. For continued compliance with international EMC regulations, it is important that all 

cables be screened, and connected as follows: Audio cable screens to their BLU-Device connector 

ground. Control cable screens to the ground screws adjacent to the connector. Network cables 

should be of type Cat 5, fitted with a clip-on ferrite sleeve (STEWART TYPE 28A2029-0A0) near 

the network socket end. This equipment must be earthed. It should not be necessary to remove 

any protective earth or signal cable shield connections to prevent ground loops. Any such 

disconnections are outside the recommended practice of BSS Audio, and will render the EMC or 

safety certificate void.

If the unit is likely to undergo extreme vibration through extensive road trucking and touring, the 

unit must be supported at the rear and/or sides to lessen the stress on the front mounting flange. 

Rear rack supports are provided to reduce stress on front mounting flange. Damage caused by 

insufficient support is not covered by the warranty. To prevent cosmetic damage to the front panel 

finish, use protective plastic cups under the rack mounting bolts.

1

2

4

3

1

2

2

4

1

4

3

3

1

2

4

3

2

1

4

3

CONTROL

ETHERNET

LOCATE

OUTPUTS

INPUTS

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

S  +

A

B

C

D

E

RS232

IN

OUT

BLU link

THIS EQUIPMENT MUST BE EARTHED

100-240V ~ 50/60Hz, 50W

MANUFACTURED IN THE USA BY BSS AUDIO

Содержание BSS Soundweb London BLU-101

Страница 1: ...1 Soundweb TM London BLU 101 Installation Guide 5033747 B...

Страница 2: ...WARNING FOR YOUR PROTECTION READ THE FOLLOWING KEEP THESE INSTRUCTIONS HEED ALL WARNINGS FOLLOW ALL INSTRUCTIONS The apparatus shall not be exposed to dripping or splashing liquid and no object fille...

Страница 3: ...shielded interconnecting cables SAFETY INSTRUCTIONS Notice For Customers If Your Unit Is Equipped With A Power Cord WARNING THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A PROTECTIVE...

Страница 4: ...STEWART TYPE 28A2029 0A0 near the network socket end This equipment must be earthed It should not be necessary to remove any protective earth or signal cable shield connections to prevent ground loops...

Страница 5: ...The COM LED turns green to indicate a normal linked condition The COM LED blinks green if data is being transferred on the Ethernet or RS232 port The LED turns yellow if a link is established but no...

Страница 6: ...e destination to eliminate ground loop problems This means that the shield S connection on an input is grounded whereas the shield connection on an output is floating although connected via an interna...

Страница 7: ...ded by completing the loop and connecting the OUT port from the last device to the IN port of the first device in the chain All devices connected in the London BLU link chain must be configured for th...

Страница 8: ...Qnet London Architect for a table of resistor values for use with Parameter Presets or source selectors Two common ground connections are provided using the two C connectors to the left of the CONTROL...

Страница 9: ...isolated output which fails safe open circuit if the unit becomes faulty switch 2 wire mode relay LED relay 3600R 1800R 1200R unconnected ladder supply voltage 47kOhm log potentiometer 10K 100kOhm lin...

Страница 10: ...to 20kHz A weighted 108dB unweighted CMRR 75dB at 1kHz Equiv Input Noise EIN 125dBu typ with 150 Ohms source Phantom power 48V nominal selectable per input A D Latency 37 Fs 0 77ms 48k AEC Up to 12 c...

Страница 11: ...Mains Voltage 100 240V AC 50 60Hz Power Consumption 55VA BTU Rating 188 BTU hr Operating Temperature Range 5 41 to 35 95 degrees C degrees F Dimensions HxWxD 1 75 45mm 1U x 19 483mm x 12 5 318mm Weigh...

Страница 12: ...12 BSS Audio 8760 South Sandy Parkway Sandy Utah 84070 801 566 8800 www bssaudio com Printed in Malaysia...