NetLinx Control 

 

Controlling the 

 VPX-1401 

 through NetLinx Studio.

 

Before launching NetLinx Studio, connect the

 VPX-1401

, PC, control system (e.g. NX-3200) to the same network.

 

 

Note:

 IDs and IP addresses in the following illustrations are examples. Check the Online Tree in NetLinx Studio to find the 

correct addresses for your device. 

 

Device Number and Ports

 

Each VPX-1401 has its own Device Number (which is assigned when the unit is bound to a Control System) and the following ports.  

Port 1: VGA IN 1 (AUDIO IN 1); HDMI OUT; HDBT OUT; AUDIO OUT 
Port 2: HDMI IN 2 
Port 3: HDMI IN 3 
Port 4: HDMI IN 4 
Port 5-8: Unused 
Port 9: RS-232 
Port 10: HOST 
Port 11: IR 
Port 12-21

:

 Unused 

Port 22: CONTACT IN  
Port 23: TALLY OUT 

 

In NetLinx Studio’s Online Tree, the VPX-1401 module displays its ports. 

 

Содержание AMX VPX-1401

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ...Audio IN OUT 15 Installation and Wiring 16 Installation 16 Wiring 16 OSD 18 Input Source Switching 19 Auto Switching 19 Manual Switching 19 IR Operation 20 Control the Source 20 RS232 Operation 21 Net...

Страница 5: ...User Manual VPX 1401 5 Logo 27 Network 28 System 29 Firmware Upgrade 32 Before Starting 32 Transferring KIT Files 32 Troubleshooting 34 APICommandSet 35 NetLinx Commands 35 Telnet SSH Commands 44...

Страница 6: ...an HDBT receiver The VPX 1401 simplifies integration and installation of a small presentation system for classrooms and small offices providing localized presentation switching support over long dist...

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...The following figures show the pinouts of the phoenix connectors RS232 IR Connects to the RS232 and IR devices with the 6 pole 3 5mm captive screw connectors Audio IN OUT Connect to audio device with...

Страница 13: ...tions for additional controloptions LANcontrol NetLinx Telnet WebUI ConnectaLocalAreaNetworktotheLANportoftheVPX 1401 Input source switching control Connect a keypad and LEDs to CONTACT IN and TALLY O...

Страница 14: ......

Страница 15: ...display its IP address Follow these steps to initiate OSD 1 Press and Hold the front panel buttons Input 1 and Input 2 for at least 3 seconds 2 The IP address of the VPX 1401 will display at the uppe...

Страница 16: ...the most recently selected port If the port has no active source the input will be switched to the active source with the highest priority Note When in Auto Switching Input Select buttons do not funct...

Страница 17: ......

Страница 18: ......

Страница 19: ...nx Studio to find the correct addresses for your device Device Number and Ports Each VPX 1401 has its own Device Number which is assigned when the unit is bound to a Control System and the following p...

Страница 20: ...evicenumber Portnumber Systemand commandrespectively andclick SendTo Device For API commands see the Section API Command Set Telnet Control LaunchTelnetWindow To launch Telnet Window 1 Right click the...

Страница 21: ...ess Enter Selecting Launch TELENT Window via User Defined Program may require enabling Telnet by completing the following 1 go to Start Control Panel Programs and Features 2 on the left select Turn Wi...

Страница 22: ...r Manual VPX 1401 22 Web UI Control To configure and control the device on the Web right click the Device Number in the Online Tree Tab choose Web Control Page Launch Web Control Page via NetLinx Stud...

Страница 23: ...ia NetLinx Studio The following page will pop up Enter the default password admin and click Login The main screen displays as follows The Web UI page consists of header bar and navigation bar for basi...

Страница 24: ...ill reboot immediately Update status button click to view the device s firmware upgrade status Logout button click to logout from the Web UI Displays the device s firmware version information Navigati...

Страница 25: ...lity for the HDMI Out which will transmit content with the same HDCP compatibility as that of the output display default setting HDCP 2 2 Select to transmit HDCP 2 2 protected content to the output di...

Страница 26: ...ime set to 2 minutes the output display will be powered off automatically when there is no signal input for 2 minutes Note The time range for Auto Display Control is 1 30 minutes Audio Output Volume M...

Страница 27: ...logo picture to shuttle slowly between the center and the top left of the display screen when there s no signal output to the display 3 DRAG TOP RIGHT Select to set the logo picture to shuttle slowly...

Страница 28: ...he connected DHCP server Static When the switcher fails to obtain or detect an IP address from the network to which it is connected select Static to set up the IP address manually APPLY Click to set t...

Страница 29: ...SS TELNET SSH ACCESS is used to enable or disable Telnet SSH capability The default setting is ON Note Reboot the device for the setting change to take effect 4 TELNET SSH ACCOUNT TELNET SSH ACCOUNT i...

Страница 30: ...User Manual VPX 1401 30 Upload Click to upload the https certificate and its private key to the device Note When certificate upload is completed the certificate module will reboot automatically...

Страница 31: ...VPX 1401 unit is powered ON 4 Launch NetLinx Studio and open the Online Tree 5 Bind the device to the integrated Controller select and right click the VPX 1401 from the context sensitive menu select N...

Страница 32: ...e to determine the system number 5 Click Send to upgrade the firmware 6 Click the button on Web UI page to check the upgrade status When the process completes the device will restart automatically Not...

Страница 33: ...ces Ensure picture can be shown normally when directly connecting a source a display device 4 Cable Plug the HDMI Cat X cable in and out or connect a different HDMI Cat X cable Ensure the specific cab...

Страница 34: ......

Страница 35: ......

Страница 36: ......

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ......

Страница 41: ......

Страница 42: ......

Страница 43: ......

Страница 44: ......

Страница 45: ......

Страница 46: ......

Страница 47: ......

Страница 48: ......

Страница 49: ......

Страница 50: ......

Страница 51: ......

Страница 52: ......

Страница 53: ......

Страница 54: ...re deployed worldwide in conference rooms classrooms network operation command centers homes hotels entertainment venues and broadcast facilities among others AMX is part of the HARMAN Professional Gr...

Отзывы: