Chapter 3: Windowing Processor Configuration Options
23
N1512 Windowing Processor User Manual
Network Setup Section
The
Network Setup
section of the
Unit Settings
page is shown in
. Options are described in
. In the
Network
Setup
section on the
Unit Settings
page:
•
IP address
is required, and will be used as the control IP address.
• Configure the
Netmask
and default
Gateway
address
as needed or directed by IT personnel.
NOTE:
If you do need to make changes to the Network Setup section, click Trial Save once changes are made. If the control IP address
is different from the default, you will need to log in to the unit using its new IP address. Once re-logged back in, click Confirm to keep
the changes. If the unit is power cycled before the changes are confirmed, it will revert to its original IP address.
FIG. 14
Network Setup Section
TABLE 5
Unit Settings Page: Stored Presets Section
Option
Description
Notes
Stored Presets field
Lists presets already stored in this device.
Sort button
Click to rearrange and re-index the
Stored Presets
in
any order.
Delete button
Click to delete the selected stored preset.
Export button
Click to export the selected stored preset to later
import to another Windowing Processor.
Choose File button
Choose a stored preset file to import to this Windowing
Processor.
Import button
Click to import the preset file chosen using the
Choose
File
button.
Append Import
checkbox
Enable this checkbox if you want to append the current
stored presets with the imported presets.
If this option is not enabled, the import will overwrite
the currently stored presets.
TABLE 6
Unit Settings Page: Network Setup Section
Option
Description
Notes
IP Mode
Configure the IP address mode. When set to
AUTO IP
,
an IP Address in the range of 169.254.xxx.xxx with
Netmask
of 255.255.0.0 and
Gateway
address
of
169.254.1.1 will be automatically assigned to the
N1512 Windowing Processor by the control software.
When set to
DHCP
,
an IP Address in the range of the
DHCP server on the network will be automatically
assigned to the N1512 Windowing Processor. When set
to
STATIC
, an
IP address
,
Netmask
, and
Gateway
address
must be manually entered.
DHCP
is the default setting. However, using
DHCP
beyond initial setup is generally not recommended. If
the device is set to
DHCP
and fails to receive an
address from the DHCP server in time, it will revert
back to the
AUTO
IP
Address (169.254.xxx.xxx) until
the unit is rebooted.
IP address
View the current IP address of the N1512 Windowing
Processor. When in
STATIC
mode, you may enter a new
IP address into this field.
Netmask
View the current
Netmask
of the N1512 Windowing
Processor. When in
STATIC
mode, you may enter a new
Netmask
into this field.
Gateway address
View the current
Gateway address
of the N1512
Windowing Processor. When in
STATIC
mode, you may
enter a new
Gateway address
into this field.
Trial Save
Click to initially save IP address changes. Once you log
in to the unit using the new address, you will be able to
confirm and accept the changes permanently.