3.

Secure the End Cap with the 4 to 6 (black) sheet metal screws (FIG. 2).

4.

Replace the (silver) pivot screw in the center of the End Cap.

Mount the HPX into the Mounting Surface

Caution: Do not use a high-powered torque screw driver. Over-tightening these screws 

can damage the product.

Note: 

For detailed instructions on installing the HPX base assembly, refer to the HPX-

600/900/1200 and HydraPort Touch (7”/10”) Installation Guides (available online at 

www.amx.com).

1.

Carefully insert the HPX base into the cutout in the mounting surface. 

2.

Tighten the four mounting screws (FIG. 10) located inside and at each end of the

HPX base assembly, to rotate the retaining tabs (FIG. 11) into locking position

under the mounting surface.

3.

Minding the twist in the cable, feed the excess cable up through the mounting

collar and insert the cable cartridge hook into the mounting collar cutout. 

Note:

 If a twist in the cable occurs from rotating the cassette before insertion, the

cable will bind and will not fully retract. 

4.

Push the cable cartridge trigger up onto the mounting collar tongue until it

latches (opposite of FIG. 4).

5.

Use the Push button to retract the cable into the cartridge. 

6.

Attach the display ends of the cables as necessary.

7.

Use cable ties to secure cable bundles as necessary.

Mounting Dimensions

FIG. 6  provides dimensions for the retractable cable module, when installed in an HPX-
600/900/1200 or HPX-MSP-07/10 base assembly. 

Optional MyTurn™ Source Selector Button 

For customers who bought the optional HPA-MYT-TX MyTurn™ Source Selector Button

(FG554-21), it clips into the specially designed groove built into the end of a MyTurn

ready cable. Users press to send the content on their device to the display. When

pressed, the button transmits a signal to an optional receiver (FG554-23) that plugs

directly into an AMX switching device such as a Solecis SDX, Enova DVX, or NX Series

Controller. 

MyTurn Source Selector Buttons are illuminated briefly when that specific device is

selected, making it easy to determine whose content is being shown on the display at

any given time. Refer to the HPA-MYT-TX documentation for further details.

Existing Installations

For existing HPX installations, the HPX Base Assembly must be removed from the table

surface before the HPX-AV102-MDP-R Retractable Cable Module can be installed.

Note:

 It may be necessary to reorient existing 1st generation RCM units in the chassis to

ensure they fit against the non lip edge of MyTurn-Ready 2nd generation RCMs.

Otherwise a 1/2 M blank panel (FG558-01) or other non retractable cable modules need

to be installed between the 1st and MyTurn-Ready 2nd Generation RCMs.

1.

Cut/remove any cable ties that would restrict the removal of the HPX Base Assembly.

2.

Loosen the four mounting screws located inside and at each end of the HPX base

assembly (FIG. 10), to rotate the retaining tabs from under the mounting surface.

Note:

 When the cover of the HPX base is open, only two of these screws are visible.

To access the other two screws, tip the cover over to the opposite open position. 

3.

Once the retaining tabs have been rotated out from under the mounting surface,

the HPX assembly can be lifted away from the mounting surface.
FIG. 11 provides a cutaway view of the End Cap, showing the retaining tabs

highlighted in both the loose position and the tightened (secure) position. 

4.

Return to the installation section at the bottom left column of page 1 to continue

with installing the RCM into the HPX Base assembly.

Replacing MyTurn-Ready RCMs

Removal of the HPX Base assembly

is not required to replace this RCM:
1.

Detach the cable cartridge 

from the mounting collar as 

shown in FIG. 4.

2.

From the top of the mounting

collar, press a small flat blade

screwdriver into the notch on

the split side of the pop out

panel and pop it out of place (FIG. 10).

3.

Slip the cable out through the mounting collar panel.

4.

Replace with new RCM in reverse order ensuring the cable is not twisted and the

pop out panel split is oriented towards the notch in the collar.

Additional Documentation

Refer to the 

Products > Architectural Connectivity 

catalog page on 

www.amx.com

(

Dealer Site

) for additional product documentation.

FIG. 6  

RCM MODULE (INSTALLED IN AN HPX BASE) - DETAILED DIMENSIONS

FIG. 9  

MYTURN SOURCE SELECTOR

1.77 ft (54 cm)

HPX Base Assembly Top

Mounting Surface Top

Removable RCM

 

cable cartridge 

mounted to 

(285.3 mm)

11.2 inches maximum

(202.5 mm)

8 inches

Removable RCM

mounting collar 

mounted to HPX 
Base

mounting collar

Cable Pigtail

FIG. 10  

HPX BASE ASSEMBLY (SHOWN MOUNTED) - MOUNTING SCREWS LOCATIONS

FIG. 11  

HPX BASE ASSEMBLY (SHOWN MOUNTED) - MOUNTING SCREWS LOCATIONS

Retaining tab

(to secure the unit)

shown tightened

Retaining tab

(to remove the unit)

shown loosened

Mounting Collar

Pop-out panel

Slip cable through

slot in panel

Notch in collar

FIG. 10  