Upgrading Firmware

32

 Instruction Manual - Massio ControlPads and Keypads

Resetting the Factory Default System and Device Values

1.

In NetLinx Studio, access the 

Device Addressing

 dialog:



Right-click on any system device listed in the Workspace and select 

Device Addressing

.



Select 

Diagnostics

 > 

Device Addressing

 from the Main menu.

2.

Click the 

Set Device/System to Factory Default

 button (FIG. 38): 

This resets both the system value and device addresses (for definable devices) to their factory default settings. The system 

information (in the 

OnLine Tree

 tab of the Workspace window) refreshes and then displays the new information.

3.

Click 

Done

 to close the 

Device Addressing

 dialog.

4.

Click 

Reboot

 (from the 

Tools > Reboot the Master Controller

 dialog) and wait for the System Master to reboot.

NOTE: 

The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporation. Wait until the STATUS LED is the only 

LED to blink.

5.

Press 

Done

 once until the 

Master Reboot Status

 field reads 

*Reboot of System Complete*

.

6.

Click the 

OnLine Tree

 tab in the Workspace window to view the devices on the System.

7.

Right-click the associated System number (

or anywhere within the tab itself

) and select 

Refresh System

. This establishes a 

new connection to the specified System and populates the list with devices on that system.

8.

Use 

Ctrl

+

S

 to save these changes to your NetLinx Project.

FIG. 38  

Device Addressing dialog

Содержание AMX FG2102-06L-BL

Страница 1: ...INSTRUCTION MANUAL MASSIO CONTROLPADS AND KEYPADS MCP 106 MCP 108 MKP 106 MKP 108...

Страница 2: ...pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 ONLY USE attachments accessories specified by the manufacturer 12 USE ONLY with a cart stand...

Страница 3: ...is connected Consult the dealer or an experienced radio TV technician for help Approved under the verification provision of FCC Part 15 as a Class B Digital Device Caution Changes or modifications no...

Страница 4: ...Serial 14 LAN RJ 45 15 Applying Power 15 ID Pushbutton 16 Installation 18 Overview 18 Mounting Procedures 18 Wallbox Mounting 18 Button Labeling 20 Overview 20 Installing Acetate Button Labels 20 Dis...

Страница 5: ...ing Massio ControlPad Firmware Files on www amx com 29 Required Order of Firmware Updates 29 Upgrading Firmware via NetLinx Studio 30 Resetting the Factory Default System and Device Values 32 Programm...

Страница 6: ...name 39 GET IP 39 GET LOCATION 39 GET SN 39 INFO 39 MSG ON OFF 39 NDP UNBIND 39 PING ADDRESS 39 REBOOT 39 RENEW DHCP 40 RESET FACTORY 40 SET CONNECTION 40 SET DEVICE 40 SET DNS 40 SET ETHERNET MODE 40...

Страница 7: ...nd maintenance Display Monitoring Use the ControlPad with RMS to monitor power status input status lamp hours and filter hours Web based Control Remotely login to ControlPads and execute button presse...

Страница 8: ...wer Draw 4 5W Power Supply External Required Any POE injector or switch conforming to the 802 3af standard including AMX s PS POE AF TC FG423 83 not included Environmental Temperature Operating 32 F t...

Страница 9: ...rature Storage 14 F to 140 F 10 C to 60 C Humidity Operating 5 to 85 RH Ethernet Ethernet Connection 1 10 100 Port provides TCP IP communication This is an Auto MDI MDI X enabled port which allows you...

Страница 10: ...ait 4 11 16 x 3 7 16 x 9 16 119 mm x 87 5 mm x 13 9 mm Landscape 3 7 16 x 4 11 16 x 9 16 87 5 mm x 119 mm x 13 9 mm Mount onto standard 1 gang US UK or EU back boxes Weight Approximately 0 25 lb 0 11...

Страница 11: ...h Indicator ID Pushbutton Reset factory settings reset factory image toggle between DHCP or static IP addressing mode Colors Available Black MKP 108L BL FG5793 08L BL White MKP 108L WH FG5793 08L W Ac...

Страница 12: ...e on each type of Massio ControlPad Here you can find wiring and electrical capacities for each type of connector FIG 3 displays the rear panel of the MCP 106 FIG 3 MCP 106 rear panel FIG 4 displays t...

Страница 13: ...EIA 232 F signal levels The RX line supports polling for RS 232 devices for statuses such as power status input status and lamp hours so that this information can be provided to RMS NOTE Massio Contr...

Страница 14: ...gic but can handle up to 12V without harm The following table provides wiring requirements for the I O port IR Serial You can connect up to two IR controllable devices to the IR connectors to the Mass...

Страница 15: ...G 10 LAN port FIG 11 provides the pinouts and signals for the LAN connector and cable FIG 11 RJ 45 wiring diagram NOTE If Ethernet connectivity is lost on any ControlPad and then re established connec...

Страница 16: ...device is restored to the factory default so you will lose any scripts IRL files Device Interrogation settings or RMS server information loaded on the system Restore the factory image on the ControlP...

Страница 17: ...dscape You can also simultaneously press buttons 4 5 and 6 to power cycle the device Press all three buttons simultaneously and hold them for 20 seconds to power cycle the device see FIG 16 FIG 16 Pre...

Страница 18: ...ox Mounting Perform these steps to mount the device into a back box 1 Install the back box into the surface of the desired location for the device Be sure to thread any appropriate wiring through the...

Страница 19: ...of the metal clip on the 6 button devices FIG 20 Metal clip from mounting bracket locking device frame onto bracket FIG 21 displays the locations of the metal clips on the 8 button devices FIG 21 Met...

Страница 20: ...l the acetate button labels and Button Caps 1 Remove the faceplate from the device 2 Remove the cone and diffuser from the button The cone and diffuser are adhered together and should not be separated...

Страница 21: ...teps This procedure requires a flat head screwdriver 1 Use the flat head screwdriver to locate the two small ridges at the bottom of the faceplate and gently pry the faceplate away from the device fra...

Страница 22: ...into place 4 Press the bottom corners of the device frame to snap them into place The metal clips on the mounting bracket should align with the open spaces located at the bottom of the device frame Th...

Страница 23: ...preferable application Before You Start 1 Verify you have the latest version of the NetLinx Studio application version 4 0 installed on your PC NetLinx Studio is available to download from www amx com...

Страница 24: ...ield to view edit the ControlPad s current Host Name NOTE Host names may contain only the ASCII letters a through z in a case insensitive manner the digits 0 through 9 and the hyphen Use DHCP Specify...

Страница 25: ...the ControlPad has an unknown static IP address you can obtain the IP address of the controller via USB 1 Using a standard Micro USB cable connect the Program Port on the rear panel of the ControlPad...

Страница 26: ...trolPad to simulate the functions of the ID pushbutton You must keep both buttons pressed for 10 seconds as you would with the ID pushbutton to toggle between IP address modes See the ID Pushbutton se...

Страница 27: ...tem click the down arrow to select which device you want to bind 5 Select the check box next to the Master to which you want to bind the keypad If there is more than one Master in the system check the...

Страница 28: ...oaded on the controller see Verifying the Current Firmware Version below Verifying the Current Firmware Version Use the OnLine Tree in NetLinx Studio see FIG 34 on page 28 to verify which version of e...

Страница 29: ...etLinx Studio as you would with a typical firmware upgrade Upgrading firmware via HTTP server is typically much faster than upgrading with the standard firmware kit files See the Upgrading Firmware vi...

Страница 30: ...enu Doing so establishes a new connection to the System and populates the device tree with devices on that system 3 After the Communication Verification dialog indicates active communication between t...

Страница 31: ...finished rebooting 9 In the OnLine Tree right click on the Master and select Refresh System This establishes a new connection and refreshes the device list and their firmware versions in your system...

Страница 32: ...the new information 3 Click Done to close the Device Addressing dialog 4 Click Reboot from the Tools Reboot the Master Controller dialog and wait for the System Master to reboot NOTE The STATUS and O...

Страница 33: ...each of the Massio ControlPads MCP 106 and MCP 108 and Keypads MKP 106 and MKP 108 Channels Channels on Massio ControlPads and Keypads correspond to the button numbers on each keypad as indicated in...

Страница 34: ...rovides level events on Level 2 Navigation Wheel Level Control In addition to generating button events a rotation of the knob causes a level change on Level 2 Clockwise rotations increase the level Co...

Страница 35: ...bar mode 2 special bar mode A level of 1 32 turns on the first LED Each successive LED that lights represents an increment of 32 steps NOTE Modes 0 and 2 operate identically Mode 2 is available for ba...

Страница 36: ...re required Enter username Enter protected password Welcome to MKP 108 v1 0 44 Copyright AMX LLC SEND_COMMANDs Cont Command Description LED EN Enable LEDs on the keypad LEDs are enabled by default Syn...

Страница 37: ...n present the password prompt Here the defined password must be entered in order to successfully open the Telnet session Additional Notes Both the Telnet user name and password are case sensitive Thre...

Страница 38: ...Supported data types UByte UInt EXIT Exit the telnet session FACTORYFWIMAGE Reset unit to factory firmware image and reboots the Module GET CONFIG Display the current connection settings Example get...

Страница 39: ...t by the SET LOCATION command on page 41 GET SN Returns the device s serial number INFO Provides at a glance information about the keypad including any expansion keypads that are attached to it MSG ON...

Страница 40: ...igned device number from the Master If the new device number is different from the old device number the Module will disconnect from the Master and begin trying to connect with the new settings NOTE T...

Страница 41: ...2 Is this correct Type Y or N and Enter y Settings written Device must be rebooted to enable new settings NOTE Metreau keypads can also be set to Static IP or DHCP Mode by using the ID Pushbutton See...

Страница 42: ...er a carriage return If an ALT 255 is entered two 255 characters are sent per the Telnet RAFT If the code to go back to command mode is entered ALT 29 which is the character is not sent but Telnet com...

Страница 43: ...ot assume responsibility for errors or omissions AMX also reserves the right to alter specifications without prior notice at any time The AMX Warranty and Return Policy and related documents can be vi...

Отзывы: