background image

SAFETY NOTICE

PlEASE rEAd ThIS ENTIrE mANuAl bEFOrE YOu INSTAll ANd uSE YOur NEw rOOm hEATEr.  FAIlurE 
TO FOllOw INSTruCTIONS mAY rESulT IN PrOPErTY dAmAgE, bOdIlY INjurY, Or EvEN dEATh.

FOr uSE IN ThE u.S. ANd CANAdA.  SuITAblE FOr INSTAllATION IN mObIlE hOmES

IF ThIS APPlIANCE IS NOT PrOPErlY INSTAllEd, A hOuSE FIrE mAY rESulT.  FOr YOur SAFETY, FOllOw 
INSTAllATION dIrECTIONS. dO NOT uSE mAkEShIFT COmPrOmISES. 

CONTACT lOCAl buIldINg Or FIrE OFFICIAlS AbOuT rESTrICTIONS ANd INSTAllATION INSPECTION 
rEQuIrEmENTS IN YOur ArEA.

CONTACT YOur lOCAl AuThOrITY (SuCh AS muNICIPAl buIldINg dEPArTmENT, FIrE dEPArTmENT, FIrE 
PrEvENTION burEAu, ETC.) TO dETErmINE ThE NEEd FOr A PErmIT.

CETTE  guIdE  d'uTIlISATION  EST  dISPONIblE  EN  FrANCAIS.  ChEz  vOTrE  CONCESSIONNAIrE  dE 
hArmAN.

SAvE ThESE INSTruCTIONS.

The harman Accentra Pellet Insert

Installation & Operating manual

“Ce manuel est disponible en Français sur demande”

R11

Item# 3-90-00674

Содержание Accentra Pellet Insert

Страница 1: ...TION DIRECTIONS do not use makeshift compromises CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authority such as municipal building department fire department fire prevention bureau etc to determine the need for a permit Cette guide d utilisation est disponible en francais Chez votre concessionnaire de Harman sa...

Страница 2: ...e placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled Soot and fly ash Format...

Страница 3: ...t Figure 60 The igniter is made to be removable for service by insulated male female wire connectors These connections between the hot leads the wires inside the burn pot and the cold leads the wires from the control board are always pulled to the inside rear of the feeder body Not coiled inside the burn pot It is very important that these connections are to the inside rear of the feeder body Also...

Страница 4: ...th a vacuum if necessary Note The bottom of the flame guide has 2 notches that match the holes Cleaning the Heat Exchanger tubes Using the cleaning brush provided clean these tubes after every 1 ton of pellets are used These tubes are an important part of the heat ex changer Efficiency will be lost if they are not properly maintained The right side tube is a straight passage to the combustion blow...

Страница 5: ...de by pulling it directly away from the blower housing The cord on the motor is long enough to allow the motor to be set down on the black plastic fan cover This allows for easy access to inspect and clean the area See Fig 66 With the blower assembly out inspection should be done on the surfaces of the blower assembly and the housing opening where they meet These surfaces MUST be clean and free fr...

Страница 6: ...l sends a status alert and at the same time the unit goes down to minimum feed minimum burn as a safety condition Accentra Insert Motor Component Locations Accentra Pellet Insert Safety Devices Backdraft Damper Assembly Always check to see if the damper plate swings freely inward and that the seating edges are not covered with dirt or lint Low Draft Pressure Switch Feed Motor Combustion Motor Dist...

Страница 7: ...tion through feed settings and ESP tem peratures When the control board has calculated poor or incomplete combustion it will shut down the unit as a safety feature Poor or incomplete combustion is a contributor of creosote which may cause a chimney fire A 6 blink status may be caused by several things 1 Blocked or partially blocked flue 2 Blocked or partially blocked inlet air a Backdraft damper o...

Отзывы: