background image

Exception F200 Wood Insert

5

The Combustion Process

Combustion in your Harman Exception wood

insert is controlled very precisely.  During a wood fire,
primary combustion air enters the bottom of the insert,
is directed up to the top of the load door and then down
past the glass, finally entering the combustion chamber.
Secondary combustion air enters the bottom of the in-
sert and is delivered directly to the afterburner behind
the firebox, where it provides the additional oxygen re-
qu ir ed  

f or  

clean  

b ur ning .

During combustion, burning proceeds through

several stages - an initial evaporation stage, where mois-
ture is released from the wood; a stage where volatile
gases containing much of the wood’s heating capacity
are released and burned; and a charcoal stage, where
the remaining charcoal burns to release the additional
heat available.  What is left after this final stage is ash.
Within the firebox, two or more of these stages are gen-
erally occurring at once.

Cette guide d'utilisation est disponible en francais

Chez votre concessionnaire de Harman Stove

Company

SAFETY NOTICE:  IF THIS HARMAN EX-

CEPTION MODEL F200 INSERT IS NOT

PROPERLY

INSTALLED, A HOUSE FIRE MAY RESULT.

FOR YOUR SAFETY, FOLLOW

INSTALLATION DIRECTIONS.  CONTACT

LOCAL BUILDING OR FIRE OFFICIALS

ABOUT RESTRICTIONS AND INSTALLA-

TION INSPECTION REQUIREMENTS IN

YOUR AREA.

  Damper Open

Damper Closed

Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.

Содержание R7R1 Exception Wood Fireplace

Страница 1: ...TY FOLLOW INSTALLATIONDIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALSABOUT RESTRICTIONSAND INSTALLATION INSPECTION REQUIREMENTS INYOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPAL BUILDING...

Страница 2: ...od burning insert Failure to follow instructions may result in property damage bodily injury or even death SAVE THESE INSTRUCTIONS Harman Stove Company 352 MountainHouse Road Halifax PA 17032 INDEX Sp...

Страница 3: ...DINSERT ISNOTPROPERLY INSTALLED AHOUSEFIREMAYRESULT FORYOURSAFETY FOLLOWTHEINSTALLATIONDIRECTIONS CONTACTLOCAL BUILDINGORFIREOFFICIALS ABOUTRESTRICTIONS ANDINSTALLATION INSPECTIONREQUIREMENTSINYOURARE...

Страница 4: ...hearth The Insert Doors Your insert has a large glass paneled door for loading and fireviewing To open the glassdoor turn the handles clockwise and pull out to closethe door return the handles to an...

Страница 5: ...itialevaporation stage where mois ture is released from the wood a stage where volatile gases containing much of the wood s heating capacity are released and burned and a charcoal stage where the rema...

Страница 6: ...se Build a bed of paper and kindling place several 1 2 25 mm 50 mm split pieces of dry wood on top followed by a few 2 3 50 mm 80 mm split pieces Ignite the paper Allow the fire to burn until a good c...

Страница 7: ...Wood ash can be added to your garden or compost When the air setting is low the blower should always be at the minimum setting corresponding to a blower speed of 750 RPM At higher settings above firs...

Страница 8: ...pieces carefully Replace glass only with Harman Insert Com pany replacement glass panels do not use substitutes To replace the glass panel s you will need to remove thedoor To do this open the door l...

Страница 9: ...once every two months during the heating season to seeif any creosote buildup has occurred Checking your chimney and chimney connector more frequently especially while you are getting used to your in...

Страница 10: ...eft and right side wings with 1 4 20 button head bolts Nextinstall top wing use the same size bolts Install andirons with 5 16 bolts and washers Install the corner panels using an 5 32 allen wrench an...

Страница 11: ...authority for informa tion if you are interested in reducing clearance distances other than those presented here From the front of the insert clearance to combus tible materials such as furniture cur...

Страница 12: ...method used a chimney cap is recommended to prevent the fiberglass from being exposed to the rain If the masonry chimney flue cross sectional area is greater than 3 times that of the insert which is 2...

Страница 13: ...eway tothe top 6 The smokeshelf internalbaffles damperand glass ormetaldoors may be removedas necessary 7 Internalparts suchasrefractorylinings firebricks insulation fireboxwalls ordoorframesmaynotbe...

Страница 14: ...LBOW 3 40 00121 21 SSS 5 16 18 X 1 4 3 30 2931180252 22 WOODEN HANDLE 3 40 00122 23 RPH MS 1 4 20 X 2 1 2 3 30 625202501 24 GOLD DOOR W ROPE 1 10 05165 CAST DOOR W ROPE 1 10 08159A 25 GLASS WITH GASKE...

Страница 15: ...cifieda certainmaterialaminimum ofoneinchthickthatis appropriate foruse as a hearth extension with theirfireplace system The k valuefor that materialis 84 You decide to use commonbrick forhearth exten...

Страница 16: ...not limited to fire lightning acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited to remote controls filters fu...

Отзывы: