19
PP38+ Pellet Stove
3-90-08422R35_10/13
Maintenance
Minimizing creosote:
Whenever wood is burned slowly, the potential exists for creosote to form in the venting. The chimney or venting system
should be inspected periodically throughout the heating season to determine if a creosote buildup has occurred. If a
significant layer of creosote has accumulated (3mm or more), it should be removed to reduce the risk of a chimney fire.
A professional chimney sweep is recommended, since they would normally have the correct equipment to ensure proper
creosote removal.
If you experience a fire in the venting system,
turn the stove to "OFF" to allow the unit to shut down. Call the fire
department, and be sure everyone is out of the residence. Before re-using the appliance, have it, and the venting system
thoroughly inspected and replace any damaged components.
The glass in your Harman stove is a special 5mm
ceramic glass.
• Do not abuse the glass by striking or slamming
the door.
• Never burn the appliance if the door glass is
cracked or broken.
• Replace only with Harman supplied glass. Do
NOT Use Substitutes.
Soot and/or fly-ash may accumulate on the viewing
glass, and will ocassionally need to be cleaned. Clean
the glass with a soft cloth and mild glass cleaner. Do
not clean the glass when hot, and avoid the use of
abrasive cleaners.
Glass replacement
Carefully remove all remaining glass and gasket
materials prior to replacing the glass.
Lay the door face down on a flat surface. Remove the
glass retainers and screws. Apply the gasket material
to the face of the new glass. Lay the glass into the
door, making sure that the glass is contained within
the channels and raised areas of the door itself. Lay the glass retainers into position and install the screws. Tighten each
screw evenly to avoid making any stress points.
Retainers and screws
Glass
Adhesive gasket
Door Frame
insPect aPPliance and coMPonents
For daMage. daMaged Parts MaY
iMPair saFe oPeration.
•
do not install daMaged
coMPonents.
•
do not install incoMPlete
coMPonents.
•
do not install substitute
coMPonents.
rePort daMaged Parts to dealer.
Fire risk.
hearth & hoMe technologies
disclaiMs anY resPonsibilitY For,
and the warrantY will be voided
bY, the Following actions:
•
installation and use oF anY
daMaged aPPliance.
•
ModiFication oF the aPPliance.
•
installation other than as instructed bY
hearth & hoMe technologies.
•
installation oF Parts or coMPonents not
suPPlied or aPProved bY hearth & hoMe
technologies.
•
oPerating aPPliance without FullY
asseMbling all coMPonents.
or anY such action that MaY cause a Fire
hazard.
WARNING
!