2

1.1

KEEP CHILDREN AWAY - MAY

CAUSE SERIOUS BURNS

C A U T I O N :

A L L

S U R FACES  OF

STOVE ARE  HOT.  DO  NOT TOUCH.
K E E P CHILDREN  AWAY.  SERIOUS
BURNS WILL RESULT IF TOUCHED.
THIS IS A HEAT PRODUCING APPLI-
ANCE. 

SERIOUS  BURNS  MAY

RESULT IF THE STOVE IS TOUCHED
DURING FIRING.

1.2

FUEL/FIRING WARNINGS

DANGER!  FIRE  HAZARD!  DO  NOT
USE  CHEMICALS  OR  FLUIDS  TO
START OR  “FRESHEN  UP”  A FIRE.
SEVERE BODY BURNS OR A FIRE IN
YOUR  HOME  COULD  RESULT.  DO
NOT BURN  GARBAGE,  GASOLINE,
THINNERS, DRAIN OR ENGINE OIL,
KEROSENE, OR FUEL OIL, ETC. AN
EXPLOSION,  A HOUSE  FIRE  OR
PERSONAL INJURY COULD RESULT.
K E E P A L L SUCH  LIQUIDS  WELL
AWAY FROM THE  STOVE WHILE IN
USE.

This  heater  is  for  burning  coal

only. Use of any other fuel except for
coal ignition is a violation of federal
law.

When and if the chimney pipes or

connectors reach 500 degrees fahren-
heit (maximum temperature), the stove
is being over fired. We recommend the
purchase  of  a  Harman  Magnetic
Temperature  Gauge  to  monitor  the
stove  and  stack  temperatures relative
to the amount of draft the customer per-
mits the stove to operate.

It  has  been  verified  that  creosote

will ignite at 650 degrees fahrenheit. It
is  the  owner’s  responsibility  to  follow
these recommendations.

This stove consumes air when it is

burning. It is advisable that a window in
the  vicinity  be  opened  slightly  while
stove is burning if your house is tightly
sealed and insulated. (Information con-
tained in this manual is manufacturer’s
recommendations  and  if  there  is  any
difference  between  our  recommenda-
tions and local code requirements, we
suggest  following  local  code  require-
ments.)

1.3

Curing Paint

During the first few hours of burn-

ing, a blue smoke will be observed ris-
ing  from  the  painted  surface  of  the
stove.  It  is  advisable  to  increase  the
amount of fresh air in the room during
this  breaking-in  period.  This  may  be
achieved  by  opening  doors,  windows,
etc. Don’t be alarmed, this is normal.

1.4

Mobile Homes

Harman  Stoves  are  not  approved

or recommended for mobile homes.

2. Assembly

Slide  blower  into  slots  as  shown.

Blower will rest at bottom of slot.

Firebrick Diagram

3. Chimney

3.1

Types of Chimneys

The  chimney  is  one  of  the  most

important, yet most neglected and mis-
understood  portion  of  any  solid  fuel
burning installation. We do not recom-
mend that the stove be connected to a
chimney with other heating devices.

THE  STOVE  MUST BE  CON-

NECTED  TO  ITS  OWN  TILE-LINED
FLUE. A MINIMUM FLUE SIZE OF 8" X
8"  IS  NECESSARY FOR  PROPER
OPERATION  AND  APPROVED  FOR
ALL FUELS.

UNDER  NO  CIRCUMSTA N C E S

SHOULD A MANUAL FLUE DAMPER
BE INSTALLED IN THE SMOKE PIPE
BETWEEN STOVE AND CHIMNEY!

1. Safety Considerations 

Содержание I

Страница 1: ...afire Mark II Magnafire Mark III Installation and Operator s Manual Caution Read Warnings and Safety Considerations Recommendations For Safe Installation Operation Please Read Carefully Built To A Standard Not A Price 2004 ...

Страница 2: ... safest manner possible If you have any questions regarding your Harman Stove which were not covered in this manual contact your local dealer or factory direct Safety Notice IF THIS STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRIC TIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA ...

Страница 3: ... Chimneys 3 2 Common Chimney Problems 3 3 What To Do When You Have A Problem 3 4 Chimney Details 4 ELECTRICAL 4 1 Electrical Warnings 5 GRATES 5 1 Grate System and Controls 6 INSTALLATION INSTRUCTIONS 6 1 Unpacking and Inspection of Parts 6 2 Warnings 6 3 Locating the Stove 6 4 General Information 7 PREVENTIVE MAINTENANCE INSTRUCTIONS 7 1 Periodic and Normal Everyday 8 OPERATING INSTRUCTIONS 8 1 S...

Страница 4: ...ve consumes air when it is burning It is advisable that a window in the vicinity be opened slightly while stove is burning if your house is tightly sealed and insulated Information con tained in this manual is manufacturer s recommendations and if there is any difference between our recommenda tions and local code requirements we suggest following local code require ments 1 3 Curing Paint During t...

Страница 5: ...ate properly In some installations a barometric draft regulator may be used and prop erly adjusted to compensate for exces sive draft IMPORTANT Whenever you measure the draft the stove must be operating and suffi cient time given for the chimney and stove to warm up This should take a minimum of thirty minutes The draft reading is taken 18 up from the center of the stove flue outlet in the smoke p...

Страница 6: ...lls This problem can usually be corrected with an open vented chimney cap 10 Make sure the chimney cleanout door is tightly closed and sealed 11 If other fuel burning devices are connected to the chimney they may be causing draft problems This must be corrected by your heating contrac tor 3 4 Chimney Details Chimney Liners Most of the cus tomer inquiries received are problems caused by poor or in ...

Страница 7: ...ass A only masonry or all fuel factory built 2 Good physical and mechanical condition 3 If manufactured chimney look for listing mark and installation in accor dance with manufacturer installation instructions 4 Multiple venting should be avoided wherever possible Never install your stove into the same vent as a gas furnace 5 Check for proper roof clear ances See pg 3 and check your local codes 6 ...

Страница 8: ...nnector to a chimney flue where the connector must pass through a combustible parti tion wall Instead of the asbestos board shown sheet metal may be used or a metal lath and plaster finish may be applied at that area Use 24 gauge or heavier metal Clearance needed is three times the diameter of stovepipe C Where all combustible material is cut out of the partition wall for a suffi cient distance to...

Страница 9: ...nts at a time Keep the draft control open Continue adding small amounts of coal until there is a solid bed of burning coal Do not add too much at one time Allow sufficient time between each small loading at least 5 10 minutes so that each loading has time to ignite thoroughly before the next load is put in When a substantial bed of burning coals has been established fill the stove to the top of th...

Страница 10: ...SED TO THE GRATES PLEASE REFER TO YOUR WAR RANTY TO SEE HARMAN STOVES LIMIT OF LIABILITY IN CASES OF ABUSE OR NEGLECT Coal produces considerably more ash than wood so the intervals between emptying are much shorter For equal heat output coal will produce seven to ten times more ash than wood 8 7 Safety Whenever a loading door is opened it always should be cracked slightly to allow oxygen to enter ...

Страница 11: ...d by which hot water will circulate automatically through the system a Shut off the hot water heater and the old water supply to it Drain the tank completely b Remove the temp press relief valve and discard Install a short 3 4 nipple and tee 1 along with a new temp press relief valve c Run 3 4 copper tubing along with the necessary fittings between the hot water tank and the top leg of the water c...

Страница 12: ...he drain valve at the bottom of the tank Install a 3 4 short nipple and tee and re install the drain valve to the tee 4 d Install a circulating pump 6 as shown Run 3 4 copper tubing from the circulating pump to the lower leg of the heat exchanger coil This is where the optional gate valve 5 can be installed to regulate the water flow e Install a 3 4 tee and a 150 lb pressure relief valve 7 in the ...

Страница 13: ...not limited to fire lightning acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited to remote controls filters fuses knobs glass ceramic brick panels ceramic fiber afterburners door packing tile ceramic log sets paint batteries or battery back up and related duct work are not covered Also excluded from this warr...

Страница 14: ......

Страница 15: ...MIP 9331 Rev 07 04 ...

Отзывы: