28
INSTALLATION (Options)
Only For Qualified Installers
Connecting the
Optional Thermostat
If the optional thermostat is used, it must be
plugged into the terminal strip located in the lower
left front corner of the heater.
When installing a millivolt control system, use
only a special low resistance thermostat. DO NOT
USE A REGULAR HEATING THERMOSTAT.
Be sure that all electrical connections are clean,
free from corrosion, and tight. Inspect connections
periodically to confirm that no corrosion has built
up over time.
When properly installed and maintained, a mil-
livolt control system should give many years of
trouble-free service.
It is important to use wire of a gauge proper
for the length of the wire:
RECOMMENDED WIRE GAUGES
Maximum
Wire
Length
Gauge
100'
14
60'
16
40'
18
25'
20
15'
22
Thermostat
Remote Control
The front button on the remote control can be
used to turn the front burner on and off. The rear
button is used to turn the rear burner on and off.
This remote uses the ultrasonic control method
and does not need to be pointed directly at the fire-
place.
A hand held sending unit, receiving unit, mount-
ing bracket and all wiring are included when you
order the remote control.
Installation instructions are packed with remote
kit.
Front Burner
Button
Rear Burner
Button