26
INSTALLATION
Only For Qualified Installers
Remove Orifices with a 1/2” wrench
or deep well socket. The larger
orifice always goes to the front.
Remove three screws to change knob assembly. Install LP
knob assembly in place of the NG assembly. Be sure screws
are tight.
9
Replace Orifices with the proper
size shown in the Orifice Chart.
10
Vent
Natural
Propane
Top
Rear
Front
Rear
Rear
Front
31
51
32
51
52
59
52
60
Orifice Chart
Remove two screws and place
Control Panel to the left.
11
12
13
Read instructions packed with LP Change-over Kit.
Place conversion sticker (provided in Kit) on bottom of
valve. This is to permanently mark the valve that it has been
converted to LP. This label is important in the event that the
valve is ever removed and mixed in with other valves.
14
Mark the proper box on the control panel with a permanent
marker. Note
: If no conversion is made, the box for the
proper fuel must still be marked.
15
Note: The higher the orifice number the smaller hole in the
tip. For example, a number 52 oifice has a larger hole than
a number 60 orifice.