Exception F200 wood Insert
1
masonry direct Connect Installation
This method is most commonly used because it is
less expensive than the other methods. A steel block-off
plate is used to seal off the chimney and allow the chimney
connector to pass through and extend into the beginning of
the tile flue liner. If the steel plate is impractical because
of some odd fireplace construction, fiberglass insulation
may be packed around the chimney connector.
To seal the flue from the living space of the home, if
this is the method used, a chimney cap is recommended to
prevent the fiberglass from being exposed to the rain.
If the masonry chimney flue cross-sectional area is
greater than 3 times that of the insert which is 28.27 sq.
in. it is recommended that a positive connect installation
be used.
Steel Plate
Tile Liner
masonry Positive Connect Installation
This method is recommended when the tile liner is
damaged beyond repair or the chimney has historically
had low draft problems. The liner, listed to UL-1777, can
be rigid or flexible with a chimney cap and top sealing
plate installed
Sealing Plate
Chimney Cap
For direct connect and positive connect
installations, ensure that the liner is securely
connected to the insert flue collar.