23
The low draft
sensor monitors
the air pressure
through a fitting
in the hopper.
Depending on
the amount of
fines in the fuel
being burned,
this fitting ,
known as the
muffler, may
need to be cleaned.
Note the location of the
muffler and use care when cleaning the hop
-
per area
. Blockage or failure will cause the feeder
to stop.
CAuTION
Excessive cleaning force could bend the
small stainless steel ESP Probe, causing
damage.
Fig. 46
Cover Retainer Handle
These surfaces must be even to
close retainer handle.
Combustion
Intake Cover
Right Side Retaining Slot
Fig. 47
Intake Cover Handle
Right Side Tab
Fig.48
ESP Probe
(in rear of flue
tube)
Combustion Fan Blade
maintenance - Combustion Intake Cover
Cleaning and maintenance for the
Combustion Intake Cover
You will need to remove the combustion intake
cover to clean the fan blades and rear flue tube.
Figure 6
Rotate the retainer cover handle counter-clockwise
upward as far as it will go (approximately 90
o
).
Figure 7
Hold the intake cover handle and pull until the side
of the cover at the retainer handle end comes away
from the stove body, approximately 15-20
o
, slide the
right side tab out of the retaining slot.
Figure 8
Clean and inspect the fully exposed combustion fan
blade and flue tube.
Reinstall the combustion intake cover by first
sliding the right side tab into the retainer slot seen in
Figure 47.
Rotate the cover inward until the cover fits
into its hole.
Make sure the two faces (Fig.46) of the cover
and retainer spacer are even and rotate the retainer
handle clockwise until it stops.
Содержание Advance
Страница 28: ...28 Advance Wiring Diagram ...
Страница 29: ...29 Advance Feeder Assembly ...