24

  FEEDER DOES NOT FEED

1. No pellets in hopper.
2. Firebox draft may be too low for low draft pres-
sure switch in feeder circuit to operate. 

Check for

closed doors

, loose or missing gasket on doors

or hopper lid, faulty pressure switch.
3. Feed motor will not run until ESP
senses 165 deg. F. Maybe you did not put
enough  pellets  in  the  burn  pot  before  lighting  the
fire.
4.  Something  is  restricting  flow  in  the  hopper  or
causing the slide plate to stick.
5. Feed motor has failed.

PARTIALLY BURNED PELLETS

1. Feed rate too high.
2. Draft too low. (Check burn  pot clean  out slide
and door gasket).
3. Burn pot or heat exchanger tubes may need  to
be cleaned.
4. Combination of all the above.
5.  #6  status  blink: A  6  blink  control  board  status
indication  is  caused  by  poor  or  incomplete  com-
bustion.  The  Advance Automatic  Ignition  circuit
board has the ability to track the combustion through
feed  settings  and  ESP  temperatures.  When  the
control  board  has  calculated  poor  or  incomplete
combustion  it  will  shut  down  the  unit  as  a  safety
feature.  (Poor  or  incomplete  combustion  is  a
contributer of creasote which may cause a chim-
ney fire)
A 6 blink status may be caused by several things:
1. Blocked or partially blocked flue.
2. Blocked or partially blocked inlet air.

a.  backdraft  damper  on  the  inlet  pipe  may  be

stuck  closed.

b. if outside air is installed the inlet cover may be

blocked.
3. The air chamber under the burnpot may be filled
with fines and small bits of ash.
4.  The  holes  in  the  burnpot  may  be  getting  filled
with ash or carbon buildup.
5.  Co mbus tio n  blower  f an  bla des   may  ne ed
cleaned.
6.  Combus tion  intake  assembly  not  prope rly
latched.
7. No fuel in hopper.

SMOKE  SMELL

Seal the vent  pipe joints and connection  to stove
with  silicone.

FIRE HAS GONE OUT

1. No pellets in hopper.
2. Draft setting is too low.
3. Something is restricting fuel flow.
4. Feed motor or draft motor has failed.
5. Power failure or blown fuse.

SMOKE  IS  VISIBLE COMING  OUT  OF  VENT

1. Air-fuel ratio is too rich.

A. Feed rate too high.
B. Draft too low caused by a gasket leak.

LOW HEAT OUTPUT

1. Feed rate too low
2. Draft too low because of gasket leak.
3. Poor quality or damp pellets
4. Combination of 1. and 2.

Trouble-Shooting

Cleaning Burn Pot

Whenever your stove is not burning, take the op-

portunity  to  scrape  the  burn  pot  to  remove  carbon
buildup. A vacuum cleaner is handy to remove the resi-
due. Be sure the stove is cold if you use a vacuum.

Carbon buildup can be scraped loose with the fire

burning using the special tool provided with your stove.
Scrape the floor and sides of the burn pot. The carbon
will  be  pushed  out  by  the  incoming  fuel. Always  wear
gloves to do this.

Removing Ashes

Turn the Temp Dial to number 1 approximately 30

minutes  before  removing  ashes.  This  will  result  in  a
cooler stove and ash pan.

Maximum Feed Adjuster settings  are not needed

in  most  cases.  Operating  in the  normal  range  (#4)  is
recommended  when  maximum  heat  output  is  not  re-
quired. The ESP probe prevents the stove from being
over-fired.

Keep the stove free of dust and dirt.

Helpful Hints

Fuel

Pellet  fuels  are  put  into  3  categories  in  terms  of

ash content. Premium at 1% or less, Standard at 3% or
less  and all others at 3% or more.

The Accentra is capable of burning all 3 categories

of pellets due to a patented feeder and burn pot system.

It should be noted, however,  that higher ash con-

tent  will  require  more  frequent    ash  removal  and  may
provide less BTU's per pound. Normally, standard and
high ash pellets cost less than premium pellets and can
be cost effective when burned in the Accentra.

The moisture content must not exceed 8%. Higher

moisture will rob BTU's and may not burn properly.

Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.

Содержание Accentra 2

Страница 1: ...R YOURSAFETY FOLLOW INSTALLATIONDIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALSABOUT RESTRICTIONSAND INSTALLATIONINSPECTION REQUIREMENTS INYOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPAL...

Страница 2: ...ed premium pellets The control is designed for easy andefficient operation It has 2 automatic modes of operation and 2 manualmodes of operation The Accentra uses a small roomsensor rather then a wall...

Страница 3: ...m temperature Therefore as it gets colder more pellets will be burned automati cally The distribution blower speed will vary according to the position of the mode selector pointer and fire size Ignito...

Страница 4: ...need to be increased After you know a feed rate setting that works well use that setting Remember ifyour feed rate is too high youmay waste fuel 5 This is usually a weekly maintence procedure Cleaning...

Страница 5: ...bution fan will not operate A 5 on the temperature dial and a 5 on the feed adjuster is approximately 80 output It is not necessary to oper ate the distribution blower below this point Therefore there...

Страница 6: ...will probably need to be increased After you know a feed rate setting that works well use that setting Remember ifyourfeed rateis too high you may waste fuel 5 This isusually a weekly maintence proce...

Страница 7: ...Room Temp Mode Stove Temp Mode orOFF Also allows you to vary the distribution blower speed by turning the knob to the high or lowside of each mode Feed adjuster Sets the maximum feed rate Test Runs a...

Страница 8: ...al must be installed between the bottom of the unit and the floor This can be a minimum of a 20 gauge sheetmetal plate ceramic tile with grouted joints a UL listed stove board or a Harman Cast Iron fl...

Страница 9: ...er moving parts will not be transferred by direct contact These rubber pads have a threaded stud that extends through the base plate The top of the threaded stud has a screwdriver slot Therefore the u...

Страница 10: ...of the Accentra Pellet Stove should be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning will...

Страница 11: ...l not allow the feeder motor or the ignitor to operate A simple draft test should be performed after completing the flue pipe installation To record the results for future reference 1 Plug unit into a...

Страница 12: ...d even if only installed on the rear of the unit as a returnair sensor There is anintake screen onthe bottomof the rear sheetmetalenclosure This is an ideal place to tyrap the sensor head to sense ret...

Страница 13: ...o layers with air space between the layers This air space acts as an insulator and reduces the outside surface temperature to allow a clearance to combustibles of only 3 inches The sections of pipe lo...

Страница 14: ...ing KEEP COMBUSTIBLES SUCH AS GRASS LEAVES ETC AT LEAST 3 FEET AWAY FROM THE FLUE OUTLET ON THE OUTSIDE OF THE BUILDING CAUTION 3 ft to combustibles 2 Preferred method This method also provides excell...

Страница 15: ...provides excellent venting for nor mal operation This method also provides natural draft in the event of a power failure The damper area must be sealed with a steel plate or fiberglass A cap should b...

Страница 16: ...increased to 4 using this method This method provides excellent venting for nor mal operation This method also provides natural draft in the event of a power failure In Canada and some places in the U...

Страница 17: ...using wall and ceiling pass through Note Do not place joints within wall pass throughs PL vent manufacturer s firestop spacer and support No insulation or other combustible materials are allowed with...

Страница 18: ...ed fromthe horizontalcenter line of the regu lator 1 I The clearance to service regulator vent outlet must be a minimum of 6 feet 1 J The clearance to a non mechanical air sup ply inlet to the buildin...

Страница 19: ...efore if the unit is turned to the lowest setting about 1 hour before cleaning it will make it possible to clean the glass with the unit in operation Any glass cleaner with a high amonia content will...

Страница 20: ...opening Repeat the process withthe secondheat exchanger cover Maintenance Cleaning Heat Exchanger channel cover latch Fig 36 Fig 35 Cleaning Internal Components Feeder Chamber This chamber may get a...

Страница 21: ...n Use the scraper provided to clean the heat exchanger surfaces A wire brush or short bristled brush is an excellent cleaning tool Clean the fan blade and combustion blower fan housing NOTE Be careful...

Страница 22: ...ctors These connections between the hot leads the wires inside the burn pot and the cold leads the wires from the control board are always pulled to the inside rear of the feeder body Not coiled insid...

Страница 23: ...ssure becomes too low for proper combustion the switch opens turning off the feeder motor and the igniter element This switch is connected into the AC high voltage wires therefore the control may show...

Страница 24: ...licone FIRE HAS GONE OUT 1 No pellets in hopper 2 Draft setting is too low 3 Something is restricting fuel flow 4 Feed motor or draft motor has failed 5 Power failure or blown fuse SMOKE IS VISIBLE CO...

Страница 25: ...ellets Outside Air Size 2 3 8 inches Fuse Rating 5 amp BTU Range 0 to 40 000 Feed Rate 75 lbs hr on minimum on maintenance 5 lbs hr on maximum Flue Size 3 inch Pellet Vent Pipe Maximum Wattage 440 Wat...

Страница 26: ...26 Accentra Wiring Diagram...

Страница 27: ...ade 8 3 30 1252010014 SHCS 1 4 20 x 3 4 3 30 3025200752 HCS 5 16 18 x 1 1 4 3 30 1311812513 Motor Mount Weldment 1 10 06603 HWH TCS 10 24 x 3 4 Black 3 30 110240753 4 Rubber Grommet 3 31 960026 4 Nylo...

Страница 28: ...lePaddle Combustion Fan Blade 3 20 40985 Combustion Blower 3 21 08639 Distribution Blower 3 21 29045 Tailpipe Insulator 3 44 247168 White Black Control Knob 3 3 31 00968 Control Knob Shaft 3 3 31 0098...

Страница 29: ...NS Failure due but not limited to fire lightning acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited to remote...

Отзывы: