17
M
in
.
a
b
o
v
e
g
ro
u
n
d
le
v
e
l
1
8
"
Minimum flue vent configuration
It is re commended that
outside air be installed with this
venting configuration to reduce
smoke and creosote smell in the
room in the event of power failure.
#8 Installing through the ceiling vent
Thr ough the ce iling vent, follow PLvent
manufacturers recommendations when using wall
and ceiling pass through.
Note: Do not place joints
within wall pass-throughs.
PL vent manufacturer's
fi re stop s pa ce r an d
support
No insulation or
other combustible
ma te ri al s
ar e
allowed within 3"
of the P L ve nt
pipe.
Storm collar
Flashing
3" min.
3" min.
3" min.
12" min.
(See Page 9 for
corner installation
clearances)
Fig. 31
Fig. 32
Fig. 33
Venting
Sha ded a r ea r epr es ents the
minimum clearance to combustible
mat er ia ls s uc h a s sh r ube r y,
mulch or tall grasses.
3
6
"
36" min clearance to any
combustible material
12" min. wall to outlet