background image

 

Hydro 1 

15

Commissioning

Manufacturer

Brand Name

Manufacturer

Brand Name

Amoco

®

Rykon 46

Gulf

®

46AW

Ashland Valvoline

®

Evergol 46

Mobil

®

DTE 20 Series 25

Atlantic Richfield

®

Duro AW-S-215

Mobil

®

DTE 10 Series 19

BP

®

Energol HLP

Pennzoil

®

Magnus A 315

Chevron

®

 USA

AW Hydraulic Oil 46

Phillips Petroleum

®

 Corp.

Tellus 46

Citgo

®

 Petroleum Corp.

A/W Pacemaker XD-46

Shell

®

Tellus T46

Citgo

®

 Petroleum Corp.

A/W 46

Shell

®

SUNTAC WR 150 WR

Conoco

®

 (Continental)

Super Hydraulic Oil 21

Texaco

®

Rando HD 46

Esso

®

Nuto H46

Union

®

Hydraulic Oil Unax AW 215

Exxon

®

Nuto H46

Registered trademarks: Amoco

®

 - Amoco Oil Company: Ashland Valvoline

®

 - Ashland, Inc.; Atlantic Richfield

®

 - Atlantic Richfield Co.; BP

®

 - BP p.l.c; Chevron

®

 USA  - Chevron Intellectual 

Property LLC; Citgo

®

 Petroleum Corp.  - Citgo Petroleum Corp.; Conoco

®

 (Continental)  - ConocoPhillips; Esso

®

 and Exxon

®

 - ExxonMobil; Gulf

®

 - GULF Oil International; Mobil

®

 - ExxonMobil; 

Pennzoil

®

 - SOPUS Products; Phillips Petroleum

®

 Corp. - Phillips 66; Shell

®

 - SOPUS Products; Texaco

®

 - Chevron Intellectual Property LLC: Union

®

 - Phillips 66.

Filling Reservoir

Pump hydraulic oil through an adequate filter into reservoir. Fill until oil 
level indicator is 

2

/

3

 - 

3

/

4

 full. Inspect for leaks. Reservoir capacity is  

30 liters (7.9 gal.). Approximately 25 liters (6.6 gal) will be needed for  
the reservoir. If installation is completed with empty hoses, extra oil  
will be needed to meet the 

2

/

3

 - 

3

/

4

 tank fill indicator requirement.

Hydraulic Oil

Harken recommends mineral-based, ISO 46 grade oil. Refer to Oil 
Equivalent Table below. If HPU is primarily used in an extreme cold  
weather environment, ISO 32 is suitable.
Characteristics of good quality, mineral-based hydraulic oil are:

•  Good anti-wear performance
•  Resistance to oxidation depredation
•  Protection against rust and corrosion
•  Resistance to foaming
•  Ability to separate water rapidly
•  Suitable for widely varying temperature conditions
•  Good low temperature flow properties
•  Retains viscosity/temperature characteristics while in service
•  Universally available

Note:

 If the hydraulic installation was completed with empty hoses,  

 

be sure to have extra oil on hand to top off the tank as the hoses  

 

are filled.

Filler Tube

Oil Level  

Indicator

CAUTION! Never run the HPU pump without oil. This will void warranty.

When commissioning hydraulic equipment, it is extremely important to carefully follow each procedure to avoid premature system damage  
and/or failure. Secure connections, ensure cleanliness, confirm proper fluid levels and perform all recommended tests. The following are 
instructions to ensure proper commissioning of your Hydro 1.

Oil Equivalent Table

Содержание HYDRO POWER UNIT 1

Страница 1: ...y be modified without notice See www harken com manuals for updated versions PLEASE SAVE THESE INSTRUCTIONS The Hydro Power Unit pictured above is for display purposes only Actual system purchased may...

Страница 2: ...onnect HPU motor and valves to ECB Connect HPU to battery COMMISSIONING 15 16 Fill reservoir Hydraulic fluid Closed circuit Leak check One way function flush System validation Function pressure check...

Страница 3: ...ipped with horizontal ports to provide ease with hose routing Elevated reservoir fill cap keeps oil from spilling filters air exchange and removes moisture from the tank to ensure a healthy hydraulic...

Страница 4: ...ulic equipment that will be driven by the power unit Note flow and pressure 2 Determine which pieces of hydraulic equipment or circuits will be used at the same time i e winch and furler 3 Compare tot...

Страница 5: ...omply with the following cautions and warnings could result in equipment damage and personal injury Symbols and Safety Statements Used in this Manual Symbols and safety statements have been placed thr...

Страница 6: ...ng in oil leaks Heat also weakens hose materials and packings For optimum performance do not expose equipment to temperatures of 65 C 150 F or higher Use caution when searching for leaks cracks kinks...

Страница 7: ...se mutual proximity recommended maximum 5 m wire run See Electrical Installation pg 12 Provide necessary clearance for HPU HPU in close proximity to battery and power supply to reduce voltage drop See...

Страница 8: ...Tie downs should attach to the mounting pad and be lashed over the HPU tank as illustrated Measure Hose Run Measure hydraulic hose runs after the HPU has been mounted Remember these important points...

Страница 9: ...ose Shortening Hydraulic hoses typically shorten 2 to 4 of total length when pressurized When routing and measuring hose lines ensure extra hose length is added to compensate for the hose shortening u...

Страница 10: ...ched or a remote manifold per design specification Both manifold styles have four 4 valve stations corresponding with four 4 ECB switches Assign each function to its own set of valve ports Record the...

Страница 11: ...ns Function motors with drain ports must be routed to a common case drain on the HPU during the installation T fittings may be used to connect multiple drain port hoses to one common hose that leads t...

Страница 12: ...to electrical standards per the National Boatbuilding Regulatory Bureau Caution DO NOT connect the cable from the battery to the HPU until all of the other steps are complete Caution Be extremely care...

Страница 13: ...on 2 Pass power supply wires through gland into the ECB case 3 Connect power supply positive lead to the circuit breaker 0CB terminal 2 4 Connect power supply common lead to any GND terminal Valve Swi...

Страница 14: ...W1A SW1B Ground 2 SW2A SW2B Ground 3 SW3A SW3B Ground 4 SW4A SW4B Ground Valve Wiring Table Connect HPU Motor and Valves to ECB Each valve operates using a three wire cable bundle with an M12 connecto...

Страница 15: ...liters 7 9 gal Approximately 25 liters 6 6 gal will be needed for the reservoir If installation is completed with empty hoses extra oil will be needed to meet the 2 3 3 4 tank fill indicator requirem...

Страница 16: ...at a time first in one direction and then in the other Single direction functions i e single speed winch are operated by one deck switch If function does not operate per specific user manual switch wi...

Страница 17: ...at load To avoid motor damage the motor is equipped with an internal thermal monitor and switch The motor is sized to run a minimum of five 5 minutes without tripping the thermal switch If overheating...

Страница 18: ...il reservoir is empty 2 Use siphon oil pump method to pull oil up through hose in filler tube Use a basin to collect oil Once oil is drained use lint free rags to clean reservoir Remove debris prior t...

Страница 19: ...reset circuit breaker Motor is not operating Check thermal switch trip light on ECB Verify proper voltage at motor Verify operation of motor relay Motor is stalling Pressure relief valve not working N...

Страница 20: ...8 316 SS HYD FIT PLUG SS G1 2A BSPP 18 1 H 53543 WIRING KIT 19 4 H 46834 HYDROEXVALVE VARIOUS HYDRO EXTRA VALVE KIT 24VDC 22 350 567 69 7 8 6 2 3 14 19 5 650 143 51 16 17 19 331 491 00 13 425 341 00 1...

Страница 21: ...ydro 1 21 Exploded View Diagram NOT SHOWN PUMP TO MANIFOLD LINE HOSE RETURN LINE HOSE 6 HOSE WITH 6 JICF END FITTINGS PUMP SUCTION LINE 3 8 PIPE 9 LONG SCH 40 FILTERED RETURN LINE 1 PIPE 8 LONG SCH 40...

Страница 22: ...22 Hydro 1 3D Rendering...

Страница 23: ...4 4 24 3 24 4 1 1 1 1 2 2 1 1 1 1 2 2 1 1 1 1 2 2 1 1 1 PL1 1 PL1 2 2 CONTACTOR COIL OFF TAS1 3 PL1 3 PL1 4 4 BLK WHT MOTOR 1 THERMAL SWITCH THERMAL BY PASS SWITCH MOTOR 1 THERMAL RELAY 24A 2 ON 24A 1...

Страница 24: ...ION SW3B SW3A SW3B VALVE 3 COIL B VALVE 3 COIL A 3 5 5 3 2 4 4 2 2 3 4 1 5 1 24 VDC 2 SOL A 3 COMMON 4 SOL B 5 PE 2 3 4 1 5 1 NOT USED 2 SOL A 3 COMMON 4 SOL B 5 PE VALVE 4 A B 24 VDC 22 WATTS PL4 2 B...

Страница 25: ...rs Customer Supplied 1M 24VDC 4KW 210 FLA Power Supply 24 Volts M1 250 A Time Delay Fuse CUSTOMER SUPPLIED BATTERIES DISCONNECT AND FUSES SUGGESTED WIRING PRACTICE FOR MOTORS SEPERATE FEED WIRES CUSTO...

Страница 26: ...26 Hydro 1 Control Box Mounting Dimensions H 50334 132 07 5 200 145 50 5 728 280 00 11 024 298 67 11 759 340 71 13 414 359 38 14 149 180 00 7 087 198 67 7 822 240 71 9 477 259 38 10 212...

Страница 27: ...D1 GND GND GND GND GND GND GND GND GND GND SW1A SW1A SW1A SW1A SW1B SW1B SW1B SW1B SW2A SW2A SW2A SW2A SW2B SW2B SW2B SW2B SW3A SW3A SW3A SW3A SW3B SW3B SW3B SW3B SW4A SW4A SW4A SW4A SW4B SW4B SW4B S...

Страница 28: ...793 Warszawa Poland Tel 48 22 561 93 93 Fax 48 22 839 22 75 Web harken pl Email polska harken pl Harken Sweden AB Main Office and Harken Brandstore V stmannagatan 81B SE 113 26 Stockholm Sweden Teleph...

Отзывы: