14
Ø6.50
Ø6.50
36
132
English
The cut-off load is factory set on the basis of the operating specifications of the winch.
Upon reaching the load threshold in the selected speed, power to the motor is cut for 5 seconds for the
first speed or 5 seconds for the second speed. Until the preset time has elapsed, the device prevents
the use of the winch only in the speed in which the load threshold was reached.
WARNING! In the event that the winch stops operating due to an overload, reduce the
load before using it again.
NOTE! If the threshold relating a speed has been reached and the preset period of time
has not expired, the speed cannot be enabled.
NOTE! To use the BRS buttons, remove the analogue contact cover device.
SPECIFICATIONS/CONDITIONS FOR USE
This section contains the technical specifications of the device.
Environmental limits
Operating temperature ...........................................................................-10 60°C
Storage temperature ..............................................................................-10 85°C
Operating relative humidity ....................................................................0 90 %
Operating voltage limits
For models with a rated value of 12 Vdc.................................................9 V 16 V
For models with a rated value of 24 Vdc.................................................18 V 32 V
Intervention threshold for low battery
For models with a rated value of 12 Vdc.................................................9 V (reset above 10 V)
For models with a rated value of 24 Vdc.................................................18 V (reset above 20 V)