background image

INSTALLATION SPECIFICATIONS 

 

BTU Ratings and Pressure Requirements  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fireplace Dimensions and Clearances 

 

Refer to the following charts to determine the proper size set for your fireplace. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

LOG SET SIZE 

 

GAS TYPE 

MAX. HEAT INPUT 

MIN. HEAT INPUT 

 

GAS INLET PRESSURE 

MAX. 

MIN. 

 

REGULATOR PRESSURE

 

22” SETS 

 

Natural 

 

Propane 

32,000 BTU/Hr. 

32,000 BTU/Hr. 

24,000 BTU/Hr. 

23,500 BTU/Hr. 

 
 
10.5 ins. WC   

13 ins. WC 

5 ins. WC 

 

11ins. WC 

 
 
4 ins. WC 

 

10 ins. WC 

 

26” SETS 

 

Natural 

 

Propane 

40,000 BTU/Hr. 

33,000 BTU/Hr. 

29,000 BTU/Hr. 

23,500 BTU/Hr. 

 
 
10.5 ins. WC   

13 ins. WC 

5 ins. WC 

 

11 ins. WC 

 
 
4 ins. WC 

 

10 ins. WC

 

 

When operating the main burner, use the control knob to raise and lower the min. and max. heat output.  Turn 
the control knob counterclockwise for max. heat and clockwise for min heat. 

Input ratings are shown in BTU per hour and are 
for elevations up to 2,000 feet.  For elevations 
above 2,000 feet, input ratings should be reduced 
4% for each 1,000 feet above sea level.  Refer to 
the National Fuel Gas Code. 

WARNING:

  OPERATION OF THIS 

APPLIANCE ON GASES FOR WHICH IT IS 
NOT EQUIPPED MAY LEAD TO CARBON 
MONOXIDE POISONING. 

 
 
 
 
 

Depth 

 
 
 
 
 

 

         

Front Width 

Log Set 

Size 

 

22” 

 
 

26” 

 

Depth 

 

12” 

 
 

12” 

 

Height 

 

16” 

 
 

16” 

Front 

Width 

 

28” 

 
 

30” 

Fireplace Dimensions 

The chart above indicates the minimum 
fireplace dimensions for each log set. 

Содержание Timberland Glow

Страница 1: ...age Refer to this manual For assistance or for additional information consult a qualified installer service agency or gas supplier This appliance is only for use with the type of gas indicated on the...

Страница 2: ...5 Gas Line Hook Up 6 Gas Pressure Check 7 Wiring Schematic Millivolt Units Only 7 Log Placement Timberland Glow 22 Model 8 Log Placement Timberland Glow 26 Model 9 Log Placement Highland Glow 22 and...

Страница 3: ...sed by a ceiling fan near the fireplace a hot furnace or an open door WARNING DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERNS 4 Due to high temp...

Страница 4: ...room can support STEP THREE ADD THE BTU Hr OF ALL THE FUEL BURNING APPLIANCES IN THE SPACE VENT FREE HEATER_________________BTU Hr GAS APPLIANCE 1 _________________BTU Hr GAS APPLIANCE 2 ____________...

Страница 5: ...ins WC 11 ins WC 4 ins WC 10 ins WC When operating the main burner use the control knob to raise and lower the min and max heat output Turn the control knob counterclockwise for max heat and clockwis...

Страница 6: ...fire In most cases they should also be adequate to prevent any discoloration or warping due to heat However each Gas Log installation will present unique circumstances creating many variables beyond...

Страница 7: ...rm with state and local codes or in absence of local codes to the National Fuel Gas Code ANSI Z223 1 IMPORTANT Before installing in a solid fuel burning fireplace the chimney flue and firebox must be...

Страница 8: ...3 Include a manual shutoff valve in the gas supply line so the appliance may be disconnected for servicing 4 Center the burner system from side to side in the firebox In a vented firebox if the dampe...

Страница 9: ...technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 7 CAUTION Label all wire prior to disconnection when servicing controls...

Страница 10: ...of the left Back Log The branch from the top log faces forward and will rest on the left Front Log Fig 2 3 1 2 3 4 5 Back Logs Front Logs Top Log Back Burner Plate Front Burner Plate Fig 1 Fig 2 Fig 3...

Страница 11: ...Install the right Top Log by placing the holes in the bottom of the right Top Log over the pins in the right Front Log The small branch on the right Top Log faces back and will rest on the extension...

Страница 12: ...back and front log The branch should be facing forward Fig 1 2 Step 5 Install the right Top Log 5 by placing the flat side of the log on the notches on the top side of the back and front log The branc...

Страница 13: ...RIAL INTO THE BURNER PORTS WARNING DO NOT PUT ANY ADDITIONAL EMBER MATERIAL ON THE BURNER SYSTEM USE ONLY WHAT WAS PROVIDED WITH THE SET PLACING ADDITIONAL EMBER MATERIAL ON THE SET MAY CAUSE IMPROPER...

Страница 14: ...NDER ON THE BURNERS OR AROUND THE PILOT 2 You may use the Volcanic Cinder to cover up the Lighting Tags that are attached to the set DO NOT REMOVE THE LIGHTING TAGS FROM THE BURNER SYSTEM THIS WILL VO...

Страница 15: ...smell gas go to the next step 5 Turn the Control Knob counterclockwise to the PILOT position 6 Push in control knob and hold it in 7 Light the pilot mounted in the front of the back burner by pushing...

Страница 16: ...rclockwise to the IGN ignition position 6 Once again the IGN position push the knob in as far as it will go This action releases gas flow to the pilot 7 While holding in the Pilot Ignitor Knob turn it...

Страница 17: ...ve on this label If you do not smell gas go to the next step 5 Depress the control knob and turn counterclockwise to the PILOT position LIGHTING INSTRUCTIONS WARNING At no time should the LIGHTING INS...

Страница 18: ...erns Do not allow fans to blow directly into the fireplace Ceiling fans may create drafts that alter burner flame patterns Sooting and improper burning will occur Installation and repair should be don...

Страница 19: ...REGULATOR 1G NG 1 REG 4 REG 4 REGULATOR 1G LP 1 REG 10 REG 10 N SPARK IGNITOR 1G 1 SIT PIEZO SIT PIEZO O 1 8 FIP X 3 8 COMPRESSION 2 70 6 2 70 6 2 P 3 8 STREET ELBOW 1G 1 SE 6 SE 6 Q 3 8 ML X 3 8 FL 1...

Страница 20: ...VALVE 1 SIT MIL NG VAVLE SIT MIL NG VALVE CONVERSION FOR NATURAL GAS 1 SITMILCNG SITMILCNG CONVERSION FOR LIQUID PROPANE GAS 1 SITMILCLP SITMILCLP G SPARK IGNITOR 1 SIT PIEZO SIT PIEZO H 3 8 ML X 3 8...

Страница 21: ...lve not fully open 4 Thermocouple connection loose at valve 5 Pilot flame not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This problem could be caused by one...

Страница 22: ...paint fumes cleaning agents pet hair or other particles are cycling thru the fireplace when it is operating 2 Gas leak 1 Logs are not positioned properly and are obstructing the flame 2 Main burner h...

Страница 23: ...y applicable to this appliance is limited in duration to the same period of time as this written Warranty Some states do not allow limitations on how long an implied warranty lasts so the above limita...

Отзывы: