background image

CAUTION 

THE DAMPER MUST BE FULLY OPEN WHEN 

OPERATING THE GAS LOGS! 

 
 

 

FIREPLACE AND CHIMNEY

 

 

  Fireplace is approved for solid-fuel burning and made of non-combustible materials. 

  Operational damper with a chimney free of any obstruction or restriction. 

  Fireplace has proper draft to accommodate decorative appliance. 

  Fireplace is free from debris or ash. 

  Fireplace is free of obstruction such as log grate, log lighter, etc.; that would prohibit 

the installation of the log set. 

  If the floor is recessed or glass doors are installed on the fireplace, the appliance may 

need to be elevated to ensure proper air flow. 

  Consult table to determine if the set is properly sized for the installation in the fireplace. 

     
     GAS LINE 

 

  Ensure gas line is in safe condition and that it is adequate for the installation. 

  Check gas line sizing to ensure it is properly sized for the appliance. 

  For ease of installation gas line should be located on the right  side of the fireplace 

when possible. 

  Turn the gas supply line off and you are ready to begin burner installation. 

 
 
 
 
 
 
Attach the damper stop clamp to the fireplace damper blade.  Position the clamp to prevent full closure 
of the fireplace damper blade. 
 
If the damper stop provided does not fit, the installer shall install a permanent damper stop that will keep 
the damper open to a minimum opening as determined on page 3 Table II of the instructions. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

  4 
 

 

DAMPER STOP INSTALLATION 

IMPORTANT: In the Commonwealth of Massachusetts the damper must be 
either permanently welded in the fully open position or completely removed. 

PRE-INSTALLATION CHECKLIST 

Prefab Fireplace 

Masonry Fireplace 

Содержание OBLO19N1T

Страница 1: ...nstaller service agency or the gas supplier NOTE This appliance is only for use with the type of gas indicated on the rating plate Solid fuels shall not be burned in a fireplace where a decorative app...

Страница 2: ...o assure their fireplace has adequate draft If fumes or soot from the gas burning are evident in the room when the damper is fully open it indicates that the fireplace draft is defective Do not operat...

Страница 3: ...ht 19 22 10 16 Factory Built Appliance Input Rate kBTU hr 20 30 34 40 Chimney Height ft Minimum Opening sq in Minimum Diameter in 10 11 3 16 6 18 8 5 22 1 15 8 6 12 6 14 5 5 17 3 20 7 5 10 8 12 3 4 14...

Страница 4: ...LINE Ensure gas line is in safe condition and that it is adequate for the installation Check gas line sizing to ensure it is properly sized for the appliance For ease of installation gas line should...

Страница 5: ...8 Male X 5 16 Compression F 68 0506 3 8 Female X 5 16 Compression G SE 6 3 8 Black Elbow H N 6 2 5 3 8 X 1 Pipe Nipple I REG 4 Regulator NG REG 10 Regulator LP J 48 6 3 8 Brass Union K AM 3 8 X 3 8 33...

Страница 6: ...m inlet supply pressure for the purpose of input adjustment is 5 0 inches natural gas 11 inches propane gas in water column The maximum inlet supply pressure is 10 5 inches natural gas 13 inches propa...

Страница 7: ...within 4 seconds Carefully check the connections for leaks using a soapy solution NOTE if the pilot will not stay lit after several tries turn the control off and call a technician IMPORTANT These co...

Страница 8: ...hem into the basket resting on the front of the basket as is shown above Fig 1 3 Place the 104 with the forks down and leaning on the 1110 as is shown above Fig 2 4 Take the 112 and 2512 and place the...

Страница 9: ...black volcanic cinders are used to cover the fireplace floor fittings and tubing around the burner system Although not functional the back cinders act as a picture frame to show off the glowing ember...

Страница 10: ...has been underwater LIGHTING INSTRUCTIONS GAS OUTLET GAS INLET Pilot Adjustment Screw Pilot Gas Supply 4 Find pilot follow metal tube from the gas control behind the burner pan Pilot Burner Thermocou...

Страница 11: ...y Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQ...

Отзывы: