Each Olde World Basket set requires a minimum 16-inch front opening height and minimum 10-

inch depth.  Table I below indicates the other critical dimensions. 

 

 
 
 
 
 
 
 

TABLE II 

FACTORY BUILT FIREPLACES 

Free opening area of chimney damper for venting combustion products from decorative 

appliances for Installation in solid fuel burning fireplaces 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

TABLE III 

MASONRY BUILT FIREPLACES 

Free opening area of chimney damper for venting combustion products from decorative 

appliances for installation in vented fireplaces.

 

 

 
 
 
 
 
 
 
 

 

SPECIFICATIONS AND DIMENSIONS 

 3 
 

 

TABLE I 

 
 

 

   

Minimum Front 

 

     Minimum  

 

Minimum 

Set Size          Opening Width 

 

       Depth 

 

    

  Height 

     

    

19”  

 

  

22”   

 

         

10” 

 

 

     

16” 

     

Factory 

Built 

Appliance Input Rate (kBTU/hr) 

20 

30 

34 

40 

Chimney 

Height* (ft) 

Minimum Opening**  (sq. in.). (Minimum Diameter (in.)) 

10 

11.3 

16.6 

18.8 (5”) 

22.1 

15 

8.6 

12.6 

14.5 (5”) 

17.3 

20 

7.5 

10.8 

12.3 (4”) 

14.5 

25 

6.6 

9.6 

10.8 (4”) 

12.6 

30 

6.2 

9.1 

10.0 (4”) 

11.3 

35 

5.7 

9.1 (3.5”) 

10.8 

40 

5.3 

7.5 

8.6 (3.5”) 

10.2 

   *  Height is from hearth to top of chimney and the minimum height is 10 ft 
   **  Chart shows minimum opening (sq. in.) for a given height and input rate 

 

Masonry 

Built 

Appliance Input Rate (kBTU/hr) 

20 

30 

34 

40 

Chimney 

Height* (ft) 

Minimum Opening**  (sq. in.) 

17.6 

25.7 

28.9 

33.8 

16.5 

23.7 

26.7 

31.2 

10 

15.1 

21.7 

24.5 

28.7 

15 

14.1 

19.9 

22.4 

26.1 

20 

12.9 

18.5 

20.6 

23.7 

30 

12.2 

16.9 

18.8 

21.6 

   *  Height is from hearth to top of chimney and the minimum height is 6 ft 
   **  Chart shows minimum opening (sq. in.) for a given height and input rate 

 

Содержание OBLO19N1T

Страница 1: ...nstaller service agency or the gas supplier NOTE This appliance is only for use with the type of gas indicated on the rating plate Solid fuels shall not be burned in a fireplace where a decorative app...

Страница 2: ...o assure their fireplace has adequate draft If fumes or soot from the gas burning are evident in the room when the damper is fully open it indicates that the fireplace draft is defective Do not operat...

Страница 3: ...ht 19 22 10 16 Factory Built Appliance Input Rate kBTU hr 20 30 34 40 Chimney Height ft Minimum Opening sq in Minimum Diameter in 10 11 3 16 6 18 8 5 22 1 15 8 6 12 6 14 5 5 17 3 20 7 5 10 8 12 3 4 14...

Страница 4: ...LINE Ensure gas line is in safe condition and that it is adequate for the installation Check gas line sizing to ensure it is properly sized for the appliance For ease of installation gas line should...

Страница 5: ...8 Male X 5 16 Compression F 68 0506 3 8 Female X 5 16 Compression G SE 6 3 8 Black Elbow H N 6 2 5 3 8 X 1 Pipe Nipple I REG 4 Regulator NG REG 10 Regulator LP J 48 6 3 8 Brass Union K AM 3 8 X 3 8 33...

Страница 6: ...m inlet supply pressure for the purpose of input adjustment is 5 0 inches natural gas 11 inches propane gas in water column The maximum inlet supply pressure is 10 5 inches natural gas 13 inches propa...

Страница 7: ...within 4 seconds Carefully check the connections for leaks using a soapy solution NOTE if the pilot will not stay lit after several tries turn the control off and call a technician IMPORTANT These co...

Страница 8: ...hem into the basket resting on the front of the basket as is shown above Fig 1 3 Place the 104 with the forks down and leaning on the 1110 as is shown above Fig 2 4 Take the 112 and 2512 and place the...

Страница 9: ...black volcanic cinders are used to cover the fireplace floor fittings and tubing around the burner system Although not functional the back cinders act as a picture frame to show off the glowing ember...

Страница 10: ...has been underwater LIGHTING INSTRUCTIONS GAS OUTLET GAS INLET Pilot Adjustment Screw Pilot Gas Supply 4 Find pilot follow metal tube from the gas control behind the burner pan Pilot Burner Thermocou...

Страница 11: ...y Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQ...

Отзывы: