background image

Installation and service must be provided by a qualified installer, service agency or the gas supplier. 

 
 
 
 
 
 

 
 
 
 

 

 
 
 
 
 
 
 
 
 

INSTALLATION AND OPERATION GUIDE FOR 

HARGROVE VENTED GAS LOGS 

HIDDEN CONTROL(HC) (1T) 

 

DESIGN CERTIFIED to ANSI Z21.60 

 Vented Decorative Appliance for Installation in  

Solid-Fuel Burning Fireplaces.    

 
 

 

NOTE:

 ADEQUATE FIREPLACE VENTILATION IS REQUIRED FOR SAFETY.                     

            

READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING. 

                INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. 
                CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

ANSI 

 

 

FOR YOUR SAFETY 

Do  not  store  or  use  gasoline  or  other 
flammable vapors and liquids in the vicinity of 
this or any other appliance. 
 

 

WARNING: 

If  the  information  in  this  manual  is  not 
followed  exactly,  a  fire  or  explosion  may 
result,  causing  property  damage,  personal 
injury, or loss of life. 
 

 

WHAT TO DO IF YOU SMELL GAS 

 

1.  Open a window. 
2.  Do not try to light any appliance. 
3.  Do not touch any electrical switch; do not 

use the phone in your building. 

4.  Immediately call your gas supplier from a 

neighbor’s  phone.    Follow  the  gas 
supplier’s instructions. 

5.  If you cannot reach your gas supplier, call 

the fire department. 
 

 

 

IMPORTANT: 

Installation and service must 

be  performed  by  a  qualified  professional 
installer, service agency, or the gas supplier. 
 

 

NOTE: 

This appliance is only for use with the 

type of gas indicated on the rating plate. 
 

 

Solid-fuels shall not be burned in a fireplace 
where a decorative appliance is installed. 
 

 

 

This  Hargrove  vented  gas  log  set  is  to  be 
installed  only  in  a  solid-fuel  burning fireplace 
with  a  working  flue  and  constructed  of 
noncombustible  material.    The  installation, 
including  provisions  for  combustion  and 
ventilation  air  must  conform  to  the 

National 

Fuel Gas Code, ANSI Z223.1/NFPA 54, or the 
CSA  B149.1,  Natural  Gas  and  Propane 
Installation Code

, and applicable local building 

code. A damper clamp is included to maintain 
the minimum permanent vent opening and to 
prevent full closure of the damper blade. The 
gas log set must be burned with the 

damper 

completely open (In the Commonwealth of 
Massachusetts the damper must either be 
welded  in  the  fully  open  position  or 
completely  removed)

  and  the  chimney  free 

of any obstructions or restrictions. 
 
The  realistic  yellow  flame  produces  carbon 
monoxide and soot.  Under normal conditions, 
these products are exhausted up the chimney.  
If  fumes  or  soot,  from  the  gas  burning,  are 
evident  in the room when the damper is fully 
open  it  indicates  that  the  fireplace  draft  is 
defective.    Do  not  operate  your  gas  log  set 
until  the  fireplace  draft  is  corrected. 

It  is  the 

home-owners responsibility to assure their 
fireplace has adequate draft. 

 

REV 081718 
 

 

Содержание Hidden Control Series

Страница 1: ...aller service agency or the gas supplier NOTE This appliance is only for use with the type of gas indicated on the rating plate Solid fuels shall not be burned in a fireplace where a decorative applia...

Страница 2: ...o assure their fireplace has adequate draft If fumes or soot from the gas burning are evident in the room when the damper is fully open it indicates that the fireplace draft is defective Do not operat...

Страница 3: ...t will fit in a fireplace the width at the front of the fireplace is the critical dimension Table I below indicates the minimum front width for each size set TABLE II Free opening area of chimney damp...

Страница 4: ...LINE Ensure gas line is in safe condition and that it is adequate for the installation Check gas line sizing to ensure it is properly sized for the appliance For ease of installation gas line should...

Страница 5: ...ator 4 SKC C Gas Control Valve 5 PG 5 8 Pedestal Grate 6 FCNW 18 x2 Non Whistling Gas Flex Connector 7 DS Damper Stop 8 RW Glowing Embers 9 VC Volcanic Cinder 10 SD 10 Sand NG sets only 11 VM Vermicul...

Страница 6: ...for installation Connect to gas IMPORTANT The minimum inlet supply pressure for the purpose of input adjustment is 5 0 inches natural gas 11 inches propane gas in water column The maximum inlet supply...

Страница 7: ...for leaks using a soapy solution NOTE if the pilot will not stay lit after several tries turn the control off and call a technician IMPORTANT These controls are factory preset and will not normally r...

Страница 8: ...logs carry a limited lifetime warranty against breakage in the original fireplace Warranty does not include labor This warranty is void if excessive handling after burning causes breakage All accessor...

Страница 9: ...has been underwater LIGHTING INSTRUCTIONS GAS OUTLET GAS INLET Pilot Adjustment Screw Pilot Gas Supply 4 Find pilot follow metal tube from the gas control behind the burner pan Pilot Burner Thermocou...

Страница 10: ...y Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQ...

Отзывы: