5
6.Test after installation
1.Check the handle can be twisted smoothly.
2.Check the function ablity of password can work.
3.Check the backup key can work.
4.Check the inner handle can open the door.
7. Technical parameter
Battery type
4pcs 1.5v AA batteries
Working voltage
4.5~6V (
Low power alarm at 4.8v
)
Password capacity
51 (
2 admin + 49 normal user
)
Ways to open
Password, Metal key
Password length
2(user ID) + 6(code) = 8 digits
The peripheral size
153mm x 162mm x71mm
Environment
Working temperature
:
-10
~
70
℃
Humidity
:
0%
~
95%
Center Distance
60mm or 70mm (2-3/4” or 2-3/8”)
Door thickness
38-53mm / 1.5”-2.1”
Initial Password
00888888
All kinds of screws and sping have 1 more to replace.