HARDY MANUFACTURING CO., INC (MODEL KBP270) PAGE 31
9-3 MODULE SPECIFIC TROUBLE SHOOTING GUIDE
Module
Failure Mode
Possible Causes
Corrective Action
Shaft set screw loose
verify set screw is tight against shaft
Motor gears locked or stripped
Replace motor
Defective Motor
Test Motor with supplied test cord. If blower
does not operate then replace. (see section
9-4)
Defective Process Control Relay
Trace wiring to control panel according to
wiring diagram
Defective Process Control Module
Contact Local Dealer and request new
Process Control Module
Excessive Moisture in fuel causing
clumps that will not pass through
Tube
Defective Motor
Test Motor with supplied test cord. If blower
does not operate then replace. (see section
9-4)
Defective Process Control Relay
Defective Process Control Module
Contact Local Dealer
Power at motor
connection but
Combustion Blower
does not operate
Defective blower
Test Blower with supplied test cord. If
blower does not operate then replace. (see
section 9-4)
Defective Process Control Relay
Defective Process Control Module
Contact Local Dealer
Stir shaft finger orifices blocked
Clear orifices (see section 9-4)
Excessive Ash buildup in Firebox
Chamber
Remove Ash Buildup from firebox. Refer to
Section VIII; 8-2
Defective pump cartridge
Replace cartridge (see section 9-4; Pump
troubleshooting)
Defective pump capacitor
Replace capacitor (see section 9-4; Pump
troubleshooting)
Defective pump motor winding
Replace Pump (see section 9-4; Pump
troubleshooting)
No Power at motor
connection
Combustion
Blower
Assy
No Power at motor
connection
Lack of Combustion
air in Firebox Burn
Chamber
Circulating
Pump
Power at outlet but
pump does not
operate
Stir
Shaft
Assy
Motor Operates but
shaft does not rotate
No Power at motor
connection
Power at motor
connection but motor
does not operate
Feed
Auger
Assy
Содержание KBP270