HARDY MANUFACTURING CO., INC (MODEL KB165) PAGE 20
SECTION VI
HEATER OPERATION
6-1
Firing the KB165
Hardy Manufacturing recommends burning clean seasoned oak hardwood in this heater:
Clean Wood means wood that has no paint, stains, or other types of coatings, and wood
that has not been treated with preservatives, including but not limited to, copper chromium
arsenate, creosote, or pentachlorophenol.
22” to 24” in length
30% moisture or less
Cured between 6 to 9 months
Heater is ready to install from the factory.
The following steps should be completed to light and operate the heater unit:
1. Once the heater has been installed, unplug the two pumps on the back of the heater.
2. Fill the heater with water by turning on the heater. The automatic fill valve will begin to fill
the tank with water which holds approximately 130 gallons.
3. Once heater is full of water, prime pumps following procedure outlined in section 2-8,
(once primed you can leave main heating pump unplugged to allow heater to reach
operating temperature quicker).
4. Open the bypass damper (located on the front right side of the heater).
5. Put paper in the firebox over the grates.
6. Add approximately 10 lbs of small kindling on top of the paper.
7. Light the paper and then close the firebox door.
8. Let it burn between 15 to 20 minutes.
9.
Open the firebox door and add 6 to 8 sticks of 2” to 4” split wood.
10. Close the firebox door.
11. Close the bypass damper and let the heater run between 30 to 40 minutes.
12. Open the bypass damper, then open the firebox door and stir the fire.
13. Once coal bed is established, load the heater firebox half full of wood.
14. Close the firebox door, and then close the bypass damper. (Temperature will begin
rising).
15. After one hour, open the bypass damper and then the firebox door.
16. Fill the heater firebox with wood.
Wood should be loaded from front to back and stacked as uniform in the firebox as
possible. DO NOT attempt to load wood across the width (crossways) of the firebox.
17. Close the firebox door and then the bypass damper.
18. Plug in the system pump on the back of heater.