Configuration
51
•
•
•
•
•
•
Step 5.
From the Rack Size pull down list, select 1/4 or as required. See HI RIO manual
for definition.
Step 6.
From the Quarter (Starting Quarter) pull-down list, select the Starting Quarter you
configured in the PLC to use for this location.
Step 7.
The Last Quarter pull-down list is selectable as YES or NO.
Step 8.
Click Save Parameters when you finish. Note that you do not have to wait until
you have configured the all the parameters to save them.
Blind Unit Operation Setup
An HI 4050-DR Rate Controller cannot be configured from the front panel as a blind unit.
In a blind unit, the Remote I/O parameters are configured from the Web browser.
Viewing the I/O Card Display
The I/O Card Menu is not configurable but is read only from the front panel. The menu
indicates whether the I/O Card is connected, A/D Count, Number of Inputs and the Number
of Outputs currently activated. The values are hexidecimal values. A table is provided
below to determine the values listed. The Input and Output values consist of a byte with the
least significant bit equal to the first Input or Output.
Viewing the Controller I/O Card
Option from the Web Page
Select Configuration from the HI 4050
Home Page and select Options to
display the Options menu.