Hardy Process Solutions HI 6600 Series Скачать руководство пользователя страница 6

channel

 

number

 

count

 

located

 

in

 

the

 

HardyNet

 

sub

menu

 

of

 

the

  

Gateway

 

module

 

menu

 

structure.

 

 

The

 

Channel

 

Identification

 

and

 

channel

 

order

 

number

 

may

 

also

 

be

 

modifed

 

in

 

the

 

HardyNet

 

sub

menu

 

section

 

during

 

system

 

set

 

up.

 

 

Once

 

the

 

discovery

 

process

 

is

 

completed,

 

proceed

 

to

 

setting

 

up

 

each

  

individual

 

channel

 

by

 

following

 

the

 

basic

 

SET

 

UP

 

instructions

 

for

 

each

  

channel

 

outlined

 

below.

 

 

Suggested

 

steps

 

when

 

setting

 

up

 

the

 

instrument

 

for

 

the

 

first

 

time:

    

Choose

 

a

 

specific

 

Weight

 

Processor

 

Module

 

to

 

set

 

up

 

by

 

selecting

 

a

 

channel

 

either

 

from

 

the

 

front

 

panel

 

display

 

or

 

on

 

the

 

webserver.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET

 

UP

 

(minimum)

 

1) Select

 

Unit

 

of

 

Measure

 

2) Input

 

Total

 

Scale

 

Capacity

 

3) Select

 

Graduation

 

Size

 

4) Select

 

Decimal

 

Point

 

Position

 

5) Input

 

Motion

 

Tolerance

 

Filter

 

1) Num

 

Averages

 

2) Waversaver

 

Calibration

 

1) Cal

 

Date

 

2) Cal

 

Method

 

a. C2

 

eCal

 

b. Hard

 

Cal

 

3) Complete

 

Cal

 

Procedure

 

Channel

 

1) Choose

 

channel

 

to

 

set

up

 

Содержание HI 6600 Series

Страница 1: ...o PLCs PACs and DSCs over a single fieldbus network This Quick Start Guide is intended for users that are already familiar with setting up Hardy Process Solutions weighing instruments A complete User...

Страница 2: ...bottom on the instrument until it snaps in place Note Heavy Gage DIN rail recommended 3 Check for proper DIN rail engagement by gently lifting up on the bottom and making sure the instrument is secur...

Страница 3: ...e terminal connectors making note of the wiring markings found on the connector labels located on the instruments Hardy Gateway Module Weight Processing Module 2 Cable HardyNet Ports located on the bo...

Страница 4: ...ary line directly from the DC power source c Make sure the VDC source is off before connecting any wires to the module and before plugging in the terminal connectors d Connect the 24 VDC voltage wire...

Страница 5: ...h an optional front panel display or through the integrated Webserver If setting up using the Webserver connect an Ethernet cable between the Hardy Gateway Module and follow the Communications Etherne...

Страница 6: ...ctions for each channel outlined below Suggested steps when setting up the instrument for the first time Choose a specific Weight Processor Module to set up by selecting a channel either from the fron...

Страница 7: ...ve 4 Place the Span Weight onto the scale 5 Press Do Cal Hi Refer to User s Guide if adjustments to other calibration related parameters are required Communication Section used for setting up communic...

Страница 8: ...P IP Properties dialog IP Address 192 168 0 101 Subnet Mask 255 255 255 000 7 Select OK on the TCP IP Properties dialog box The computer is now fully configured To return the computer to the original...

Страница 9: ...MENU TREE...

Страница 10: ...e revision Language Section used for changing language Operations Section used for setting up parameters related to Tare Count and Zero of scale Security It is highly recommended to see the User s Gui...

Страница 11: ...Notes...

Страница 12: ...hould you not understand any information in this guide or experience any problems with this product please contact our Technical Support Dept at Phone 858 278 2900 Toll Free 1 800 821 5831 FAX 858 278...