AFB-PRO User Manual                                                             

Page 4 of 8

 

 
 

1.0

 

Intended Use 

 

The 

AFB-PRO 

microbiology stainer has been designed to automate most procedures that 

use a Modified Auramine O Stain and Modified Auramine O Decolorizer Staining 
process for Acid Fast Bacillus samples.   
 

2.0

 

Operator Responsibility – Safety Instructions 

 

The AFB-PRO ensures safe operation when installed, operated, and maintained according 
to common safety regulations. This section explains all the potential dangers that may 
arise when operating the AFB-PRO and also specifies the most important safety 
precautions to prevent mishaps. 
 
The operator is responsible for the qualification of the personnel operating the 
instruments. The operator and personnel is also advised to refer to this Operating Manual 
and/or call the QuickSlide™ Technical Support phone number for additional assistance. 

 

2.1 

Explanation of Safety Notes 

 
 
 
 
 
 
 

  
2.2 

Safety Instructions 

 
 
 
 

 

 
 
 
 
 
 

CAUTION

Describes a possibly dangerous situation. If this is not avoided, slight or 
minor injuries could result. A warning of possible property damage may 
also be contained in the text. 

CAUTION: 

 

Instrument must to be placed on a level operating surface. 

 

Read and understand all instructions and safety precautions listed 
in this manual before installing and operating the unit. 

 

Only use the required QuickSlide™ AFB-PRO staining reagents 
(Cat. no. AFB-0070). 

 

Only use the required QuickSlide™ tubing kits (Cat. no. AFB-
0020). 

 

Always make sure tubing is placed correctly and is not leaking. 

 

Always turn off the unit and disconnect the power supply before 
performing any service or maintenance procedures or moving the 
unit. 

Содержание QuickSlide AFB-PRO

Страница 1: ......

Страница 2: ...ty Safety Instructions 4 2 1 Explanation of Safety Notes 4 2 2 Safety Instructions 4 3 0 Instrument Setup 5 4 0 Operating Instructions 5 4 1 General Guidelines 5 4 2 Stain Procedure 6 4 3 Reagent Replacement 6 4 4 Menu Options 7 4 5 Setting Fill Levels 7 5 0 Maintenance 7 6 0 Service and Supplies 8 7 0 Safety Data Sheets 8 ...

Страница 3: ... 9001 2008 All products are shipped to you from our manufacturing facility located at 3411 McNiel Ave Suite 302 Wichita Falls Texas 76308 Unpacking and Inspecting Carefully unpack the AFB PRO and accessories Check for damage incurred during transit Keep all packing material until you are sure the unit operates properly Any damage to the shipping box should be reported to the responsible carrier or...

Страница 4: ...personnel is also advised to refer to this Operating Manual and or call the QuickSlide Technical Support phone number for additional assistance 2 1 Explanation of Safety Notes 2 2 Safety Instructions CAUTION Describes a possibly dangerous situation If this is not avoided slight or minor injuries could result A warning of possible property damage may also be contained in the text CAUTION Instrument...

Страница 5: ... water container and place DI labeled line in the water for the rinse cycles 3 1 5 Place the waste tube in the waste container 3 1 6 Turn the instrument on The instrument will go through a self test and then display prime or continue 3 1 7 Press F1 to prime Two primes are required on initial set up 4 0 Operating Instructions 4 1 General Guidelines 4 1 1 Make sure the specimen smears are thoroughly...

Страница 6: ...d remove the empty Reagent Pack Don t forget to empty the waste container at this time 4 3 4 Place the new Reagent Pack on the instrument connect the NEW phone connector from the NEW Reagent Pack and place the reagent cannulas in the new reagent bottles and insure DI water line is in a source for DI water 4 3 5 Turn the instrument on and the Self Test menu will be displayed The cuvette is automati...

Страница 7: ...nes must be replaced every 6 to 12 months depending on use To perform this procedure do the following 5 1 Remove the lines from the stain bottles 5 2 Prime the unit twice to remove fluid from the old tubes 5 3 Shut the unit off 5 4 Unscrew the two thumbscrews holding the pump cover in place 5 5 Remove the lines one at a time and replace starting from left to right The longest lines are to be posit...

Страница 8: ...ort team at 800 295 9588 If additional supplies are needed reagents and tubing kits can be ordered through Hardy Diagnostics Customer Service Call 800 266 2222 or go to www HardyDiagnostics com Alternatively you can contact your preferred distributor Catalog Number Description AFB 0070 AFB PRO Stain Kit AFB 0020 AFB PRO Replacement Tubing Kit AFB 0800 AFB QC Slides Box of 50 PF72P ProSlide Frosted...

Отзывы: