Hardy Diagnostics IncuPRO 133000H Скачать руководство пользователя страница 8

N2400386 

 

               IFU - XXXXX 

 

 

9.0

 

Warranty 

When used in laboratory conditions and according to these operating 
instructions, Hardy Diagnostics warrants this product to be free of defective 
material and workmanship for a period of two years from the date of 
manufacture.  The liability of Hardy Diagnostics for any defective equipment 
during the warranty period shall be limited to the repair of such equipment or 
replacement thereof without charge for parts or labor. 

 

10.0

 

Service 

It is required to obtain a Returned Material Authorization (RMA) number before 
any Hardy Diagnostics products are returned for any reason.  A Decontamination 
Certificate must be completed, signed by the user, and returned to Hardy 
Diagnostics prior to receiving the RMA number.  Please be sure to mark the 
outside of the returned goods package with this RMA number to ensure prompt 
handling. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Manufactured for 
Hardy Diagnostics  
1430 McCoy Lane 
Santa Maria, CA  93455 
Phone: (805) 346-2766 
Technical Support: (800) 266-2222 (option 2) 
E-mail: 

[email protected]

 

 

Website: 

www.HardyDiagnostics.com

 

 

 

Содержание IncuPRO 133000H

Страница 1: ...IFU XXXXX IncuPRO Incubator Model 133000H Operating Instructions...

Страница 2: ...packing 3 3 2 Installation 3 4 0 Operation 4 4 1 Controls and Indicator Lamps 4 4 2 Setting the Temperature 4 4 3 Operating the Incubator 5 5 0 Accessories 5 6 0 Fault Diagnosis 5 7 0 Technical Specif...

Страница 3: ...supply that provides a safety ground terminal Before moving disconnect at the power supply socket Do not remove the plug from the rear of the unit Do not check the temperature by touch but instead use...

Страница 4: ...age Report all shipping damage to the carrier immediately Shipping damage is covered by the carrier and repair replacement for shipping damages must be coordinated through the carrier Complete and ret...

Страница 5: ...erature adjust knob is used to control the chamber temperature Temperature Adjust Knob Power Switch O I Heater Lamp Temperature Display 4 2 Setting the Temperature Use the temperature adjust knob to s...

Страница 6: ...le Shelf Catalog Number C1902053 5 2 Shelf Bracket Catalog Number A1903208 6 0 Fault Diagnosis Symptom Possible Cause Action Required 1 Unit does not operate a Unit not switched on b Unit not plugged...

Страница 7: ...aning If a spill occurs use appropriate clean up procedures as required for radiation or biohazard control The outer casing may be cleaned with water and a damp cloth Do not submerge or immerse the In...

Страница 8: ...harge for parts or labor 10 0 Service It is required to obtain a Returned Material Authorization RMA number before any Hardy Diagnostics products are returned for any reason A Decontamination Certific...