9
INSTALLATION - DC
CABLE & FUSE GUIDE
440A
0A
FUSE
FUSE
Positive cable length
Negative cable length
TOTAL CABLE LENGTH = POSITIVE CABLE NEGATIVE CABLE LENGTH
FUSES MUST BE FITTED CLOSEST TO BATTERY POSITIVE TERMINAL
CABLE LENGTH (COMBINED)
HKPINVAC1000
HKPINVAC2000
HKPINVAC3000
0 - 1M
35mm² (2)
70mm² (2/0)
95mm² (3/0)
1 - 2M
35mm² (2)
70mm² (2/0)
95mm² (3/0)
2 - 3M
50mm² (1/0)
95mm² (3/0)
120mm² (4/0)
3 - 4M
70mm² (2/0)
120mm² (4/0)
Not recommended
4 - 5M
95mm² (3/0)
Not recommended
OVER 5M
Not recommended
FUSE SIZE
HKPINVAC1000
HKPINVAC2000
HKPINVAC3000
MEGA FUSE
150A
250A
350A
CABLE GAUGE mm² (AWG)
Mega-fuse
The cable between the inverter and battery must be of a large enough gauge to prevent significant voltage
drop over the length of the cable. Because voltage drop occurs between the battery positive and ground, the
total cable length combined (positive and negative) needs to be considered.
NOTE: The cables should be routed in a way that prevents them from being damaged. Consider cable conduit
or protective tubing to reduce abrasion.