![Hardinge T-51 Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/hardinge/t-51/t-51_installation-and-extended-storage-instructions_3873725051.webp)
CHAPTER 2 - EXTENDED STORAGE
- CAUTION -
These procedures should be used when the machine will sit idle or be stored for a
period of one or more months.
- NOTE -
Refer to the maintenance manual (M-506) for additional information.
BATTERY MAINTENANCE
The recommended replacement interval for the control and axis batteries is once a year. Check the
age of the control and axis drive batteries. Replace the batteries if they will expire before the machine
is to be put back into service.
Batteries are located in two places on the machine:
•
The control battery is behind the control display panel and on top of the control
unit
•
The axis drive batteries are on the drive units in the power case
CONTROL BATTERY
- CAUTION -
A fresh battery must be installed at least once a year. Failure to perform this main-
tenance will result in the loss of control information.
Battery replacement can be done with the control turned ON or OFF. If the power
is OFF, the change MUST be done within 30 minutes of when the power was
turned OFF.
Check the age of the control battery. Replace the battery if necessary:
The control can temporarily maintain memory for approximately 30 minutes without the battery
backup.
Battery Specifications
Hardinge Part Number:
18 -0011865-TB
Voltage Rating:
3 volt
Battery Type:
Lithium
M-507C
2-1
Содержание T-51
Страница 8: ... NOTES vi M 507C ...
Страница 50: ... NOTES 1 42 M 507C ...
Страница 84: ... NOTES 2 34 M 507C ...
Страница 86: ...Hardinge Inc Elmira New York 14902 1507 USA Phone 607 734 2281 Fax 607 734 8819 www hardinge com ...