3

16C Low-Pressure Dead-Length Collet Blocks

 Instructions B-145

Hardinge Inc.  One Hardinge Drive, Elmira, New York U.S.A. 4902-507  800.843.880 (Canada 800.468.5946)   www.hardingetooling.com

Par

t No

. B -0009500-0

45

 

CLAMP

UNCLAMP

PNEUMATIC

CONTROL VALVE

#7799-00-00-000065

PNEUMATIC

COLLET CLOSERS

(double-acting)

AIR SUPPLY

FIXTURE PLATE

Example of a simple pneumatic configuration

Components include a control valve and three pneumatic collet blocks supplied by Hardinge mounted on a customer 
machined fixture plate.  Two connector bushings are used between each collet block for internal plumbing.  A total of four 
connector bushings would be used in this example. (schematic shown in clamp position)

Dimensions for mounting holes are available on the installation instructions online at www.hardingetooling.com

Содержание 16C

Страница 1: ...ssure of 250psi air or 1207 psi hydraulic 17 bar air 83 bar hydraulic Make sure that the collet retains your material when the closer is closed Application This 16C collet block is a stationary unit with a double acting cylinder It is effective on machine and assembly operations that require reliable clamping and unclamping Use the collet block as a single unit or mount multiple closers on rotary ...

Страница 2: ...to this closer above 250 psi air or 1207 psi hydraulic 17 bar air 83 bar hydrualic may overstress the 5C collet 8 To open the collet actuate the valve Maintenance If over a period of time you experience a decrease in clamping force even though pneumatic or hydraulic pressure remains unchanged remove the collet block from service disassemble and replace any damaged or worn o rings Warranty The prod...

Страница 3: ...ting AIR SUPPLY FIXTURE PLATE Example of a simple pneumatic configuration Components include a control valve and three pneumatic collet blocks supplied by Hardinge mounted on a customer machined fixture plate Two connector bushings are used between each collet block for internal plumbing A total of four connector bushings would be used in this example schematic shown in clamp position Dimensions f...

Страница 4: ...mp control valve and three hydraulic collet blocks supplied by Hardinge mounted on a customer machined fixture plate schematic shown in clamp position 5000 psi 344 bar rated hose tubing is recommended Dimensions for mounting holes are available on the installation instructions online at www hardingetooling com Example of a quick disconnect hydraulic configuration Components include a pump control ...

Отзывы: