4.14 Self Cleaning Fil ter (optional)
This fi lter automatically fl ushes out particles and chemical deposits,
re duc ing routine main te nance, nozzle plugging and operator exposure.
No ad just ments are required but different mesh screens may be installed
for various types of products. The mesh size of the fi l ter in use should
al ways be small er than the fl ow av er age of the noz zles used.
Self-Cleaning Filter
Operating Diagram
1.
From
pump
2.
Double
fi lter screen
3.
Guide
cone
4. To operating unit
5.
Replaceable
restrictor
6. Return to tank
Choice Of Correct Restrictor for S.C.F.
It is important to have a large fl ow though the self clean ing fi lter. This
is achieved by choos ing the restrictor size in re la tion to the liquid
con sump tion of the spray boom.
The hose (A) is un screwed from the self-clean ing
fi lter. Be careful not to lose the seal ball or spring
when the restrictor is put in the hose and the hose
is re fi t
ted. If the re quired working pres sure can not
be ob tained, the restrictor is too large. 4 Restrictors
are supplied. Use the green one (larg est or i fi ce) fi rst.
Choose the next smaller restrictor. Start with a black
one, then a white and fi nal ly a red one.
Содержание N Series
Страница 1: ...N SERIES 3 PT SPRAYER DIAPHRAGM Operator s Manual 67302903 08 10 ...
Страница 2: ......
Страница 61: ...59 HARDI N SERIES 3 PT SPRAYER DIAPHRAGM OPERATOR S MANUAL A X 10 B X 50 2 3 40 55 55 1 X 40 X 56 ...
Страница 62: ...60 HARDI N SERIES 3 PT SPRAYER DIAPHRAGM OPERATOR S MANUAL 4 8 X 57 5 8 X ...
Страница 74: ...72 HARDI N SERIES 3 PT SPRAYER DIAPHRAGM OPERATOR S MANUAL 12 0 NOTES ...
Страница 75: ......