67
HARDI
MEGA 230 / 350 CENTRIFUGAL OPERATORS MANUAL
10.1 Nozzle Tubes and Fittings (cont'd)
The O-rings need to be lubricated
ALL THE WAY AROUND
before fitting
on to the nozzle tube.
Fig. 44
HARDI recommends using a vegetable based oil to prolong the life of the
O-ring.
Fig. 45
10.2 Checking the Valve Cone in Distribution Valves
Periodically check the distribution valves for proper
sealing.
Flush the sprayer with clean water and open
master on/off and all distribution valves. (Shut
sprayer off)
Remove clip
A
(Fig. 46) and remove hose
B
for
the constant pressure device. When the housing is
drained make sure everything is clear from part
B
then start sprayer, there should not be any flow of
liquid through the constant pressure passage. If
there is any leakage, the valve cone
E
must be
changed. (Shut sprayer off.)
Remove clip
C
, and pull the EC-motor off the valve
housing. Then remove
D
screw and replace the
valve cone
E
. Reassemble in opposite sequence.