7 - Fault finding
68
Hydraulic system - H/Y model
FAULT
PROBABLE CAUSE
CONTROL/REMEDY
Boom slow/eradic.
Air in system.
Loosen ram connection and activate hydraulics until
oil flow has no air in it (not whitish).
Regulation valve incorrectly set.
Open or close until desired speed is achieved
(clockwise = less speed).
Remember oil must be at operating temperature.
Insufficient hydraulic pressure.
Check output pressure of tractor hydraulics. Minimum
for sprayer is 170 bar.
Insufficient amount of oil in tractor reservoir.
Check and top if needed.
Ram not functioning.
Restrictor or regulation valve blocked.
Secure boom. Dismantle and clean.
Hydraulic system fold/tilt functions will not operate. Power supply.
Check for proper 12V power supply.
One function (fold or tilt) will not operate.
Various.
Check for defective switch(s).
Check continuity of cables.
Check for operation of applicable solenoid (coil not
activating or plunger stuck).
Check for short circuit in wiring junction box at rear of
sprayer.
Dirt in the restrictor port of the cylinder.
Multiple hydraulic functions with one switch
activated.
Various.
Check for correct solenoid electric/hydraulic hook-up.
Check for short circuit in wiring in the junction box at
rear of sprayer.
Содержание MASTER PRO VHH
Страница 6: ...Table of Contents 6 ...
Страница 8: ...1 EC Declaration 8 ...
Страница 12: ...2 Safety notes 12 ...
Страница 50: ...5 Operation 50 ...
Страница 52: ...6 Maintenance 52 Boom lubrication oiling plan Lift lubrication oiling plan ...
Страница 70: ...7 Fault finding 70 ...
Страница 76: ...8 Technical specifications 76 Charts Boom hydraulic Z ...
Страница 77: ...8 Technical specifications 77 Boom hydraulic Y A Option for slanting B Option for single side folding VHH only ...
Страница 78: ...8 Technical specifications 78 ...
Страница 82: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...