6 - Maintenance
58
Level indicator cord renewal
If the cord on the level indicator has to be changed, the float guide pole is removed:
1.
Remove the tank drain valve (see paragraph “Drain valve seal renewal”) and loosen the fitting holding the pole in posi-
tion.
2.
Pull the pole down through the drain valve hole till it is free in the top of the tank.
3.
The pole can now be taken out of the tank through the filling hole.
€
DANGER! Do not enter the inside of the tank - the parts can be changed from the outside of the tank!
Drain valve seal renewal
If the main tank drain valve leaks, the seal and seat can be changed the
following way.
€
DANGER! Do not enter the inside of the tank - the parts can be
changed from the outside of the tank!
±
WARNING! Use eye / face protection mask when dismantling the
tank drain valve!
1.
Make sure the tank is empty and clean.
2.
The valve must be closed and the string loose.
3.
Pull out the clip (A) and pull down connecting piece (B). The entire
valve assembly can now be pulled out.
4.
Check cord and valve flap assembly (C) for wear, replace seal (D)
and assemble again.
5.
Assemble the valve assembly again using a new valve seat (E). Lubricate O-rings (F) before assembly.
6.
Fit clip (A) again.
μ
ATTENTION! Check function of valve with clean water before filling chemicals into the tank.
Adjustment of 3-way valve
The MANIFOLD valve can be adjusted if it is too tight to operate - or if it
is too loose (=liquid leakage). Correct setting is when the valve can be
operated smoothly by one hand. Use a suitable tool and adjust the
toothed ring inside the valve as shown on the drawing.
Содержание MASTER PRO VHH
Страница 6: ...Table of Contents 6 ...
Страница 8: ...1 EC Declaration 8 ...
Страница 12: ...2 Safety notes 12 ...
Страница 50: ...5 Operation 50 ...
Страница 52: ...6 Maintenance 52 Boom lubrication oiling plan Lift lubrication oiling plan ...
Страница 70: ...7 Fault finding 70 ...
Страница 76: ...8 Technical specifications 76 Charts Boom hydraulic Z ...
Страница 77: ...8 Technical specifications 77 Boom hydraulic Y A Option for slanting B Option for single side folding VHH only ...
Страница 78: ...8 Technical specifications 78 ...
Страница 82: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...