11
Anti-freeze precaution
If the sprayer is not stored in a frost free place you should take the
following precautions: Put at least 10 litres of 33% anti-freeze mixture
in the tank and let the pump run a few minutes so that the entire
system including spray hose are filled. The anti-freeze solution also
hinders the O-rings and gaskets from drying out.
Remove the glycerine filled pressure gauge and store it frost free in
vertical position. The anti-freeze solution also hinders the O-rings and
gaskets from drying out.
Relieve the pressure regulating spring.
Operational problems
In cases where breakdowns have occurred the same factors always
seem to come into play:
• Minor leaks on the suction side of the pump will reduce the pump
capacity or stop the suction completely.
• A clogged suction filter will hinder or prevent suction so that the
pump does not operate satisfactorily.
• Clogged up pressure filters will result in increasing pressure at the
pressure gauge but lower pressure at the nozzles.
• Foreign bodies stuck in the pump valves with the result that these
cannot close tightly against the valve seat. This reduces pump
efficiency.
• Poorly reassembled pumps, especially diaphragm covers will allow
the pump to suck air resulting in reduced or no capacity.
• Unclean electric components causes poor connections.
Therefore ALWAYS check:
1. Suction, pressure and nozzle filters are clean.
2. Hoses for leaks and cracks, paying particular attention to suction
hoses.
3. Gaskets and O-rings are present and in good condition.
4. Pressure gauge is in good working order. Correct dosage depends
on it.
5. Operating unit functions properly. Use clean water to check.
6. Keep the electric components clean.
Содержание KS Series
Страница 1: ...KS TR PU Instruction book 674295 GB 06 1999 www hardi international com...
Страница 23: ...21 7 Intermediate brackets...
Страница 24: ...22 A3 500 4...
Страница 25: ...23 500 HT A4...
Страница 26: ...24 A7 600 4...
Страница 27: ...25 320 A8...
Страница 28: ...26 A103 P 3 L...
Страница 29: ...27 Unit M600 600HT B1...
Страница 30: ...28 B7 BK180K...
Страница 31: ...29 Distribution valves BK180 B10...
Страница 32: ...30 B12 N 2...
Страница 33: ...31 Suction filter B200...
Страница 34: ...32 B300 Suction pulsation dampers...
Страница 35: ...33 500HT el H1...
Страница 36: ...34 H2 500 600 el...
Страница 37: ...35 500HT petrol H3...
Страница 38: ...36 H4 500 600 petrol...
Страница 39: ...37 320 petrol H5...
Страница 40: ...38 H100 KS 100...
Страница 41: ...39 KS 120 H101...
Страница 42: ...40 H102 TR 22 300...
Страница 43: ...41 PU 200 300 H103...
Страница 44: ...42 H104 PU 800...
Страница 45: ...43 PU TPS H108...
Страница 46: ...44 K 105 Hose reel with bracket...
Страница 47: ...45 60 S L K110...
Страница 48: ...46 K 112 Spray lance adjustable...
Страница 49: ...47 Spray lance 3 way nozzle tube K113...
Страница 50: ...48 K 400 4 m boom KS TR...
Страница 52: ...HARDI INTERNATIONAL A S Helgesh j All 38 DK 2630 Taastrup DENMARK...