General FrontTank Operation

Valve Settings

Filling the FrontTank

Filling the FrontTank is done by transferring the pre-mixed spray liquid to 
the FrontTank from the MainTank.

1.

Select suction from the MainTank 

 on the FT 3610 Control 

box.

2.

The correct procedure is to mix the chemicals in the Turbofiller as 
described in the MEGA Instruction book chapter 5 - Operation 
“Filling liquid/powder chemicals using the TurboFiller”.

3.

Pump the spray liquid from the MainTank to the FrontTank, using the 
valve settings shown in the illustration.

μ

ATTENTION! It is not possible to use the TurboFiller and pump 
liquid from the MainTank to the FrontTank at the same time, it must 
be done in two individual procedures.

Emptying the FrontTank

Emptying the FrontTank can be done by transferring the spray liquid in 
the FrontTank to the MainTank.

1.

Pump the spray liquid from the FrontTank to the MainTank, using the 
valve settings shown in the illustration.

2.

Select suction from the FrontTank 

 on the FT 3610 control 

box.

Spraying with Suction from the FrontTank

Spraying using the spray liquid in the FrontTank.

1.

Position the valves as shown in the illustration.

2.

Select suction from the FrontTank 

 on the FT 3610 control 

box.

3.

Press the Main ON/OFF button for spraying on the Grip to begin 
spraying with suction from the FrontTank.

±

WARNING! It is very important to use at least 1/3 of the spray liquid 
in the MainTank before switching to suction from the FrontTank. 
This will prevent overfilling the MainTank caused by the return flow 
from the spray boom.

μ

ATTENTION! Always bleed the air out of the system when 
intending to use the spray liquid in the FrontTank, getting trapped 
air out of the system is necessary to ensure a steady and 
continuous application of the spray liquid.

Содержание Front Tank

Страница 1: ...FRONTTANK FT 3610 Original User Guide for MEGA 67058500 100 version 1 00 GB 07 2020 www hardi international com...

Страница 2: ...9 onwards and the 1200 1500 Litres HARDI FrontTank User guide Formalities The original user guide is approved and published in English All other languages are translations of the original user guide I...

Страница 3: ...r 5 seconds to switch the FT 3610 control box off NOTE The system is ready to use when the ON OFF LED shows a steady light Suction from the FrontTank MainTank Selecting suction from the FrontTank or t...

Страница 4: ...d off at the FrontTank button 2 C Press button 3 to select suction from the MainTank ensure the LED light is turned on at the MainTank button ATTENTION D There must be a steady LED light for either su...

Страница 5: ...e it takes to empty the RinseTank This should be done before any spray job and cleaning is carried out NOTE The cleaning procedure is split into three cycles each running approx 1 3 of the measured ti...

Страница 6: ...ng the spray liquid in the FrontTank to the MainTank 1 Pump the spray liquid from the FrontTank to the MainTank using the valve settings shown in the illustration 2 Select suction from the FrontTank o...

Страница 7: ...ARDI as brand 3 Select Online Catalogue and find your spare part 4 Online ordering is also possible 5 Contact your HARDI dealer for further information on spare parts User Evaluation Dear Reader We up...

Страница 8: ...HARDI INTERNATIONAL A S Herthadalvej 10 DK 4840 N rre Alslev DENMARK...

Отзывы: