A L P H A 2 5 0 0
S P R AY I N G
CHAPTER
4- 11
677824
4-
3
-
4
A D D I N G T H E P R O D U C T S
Adding by gravity
!
- Make sure that the boom sections are turned off on the Regulor
- Engage the pump at idle speed and progressively accelerate approx. 2000 rpm
- Close valve n° 6 (fig 2-1).
- Position valve as above. (fig 2-2).
!
3
2
1
8
5
9
4
6
7
6
OUVERT
CLOSED
F i g 2-1
F i g 2-2
Adding by means of the mix/admixture unit
WARNING: Wear gloves, glasses and face protection shield when operating.
Fill up the main tank to half capacity before incorporating chemical
product..Consult chemical label regarding precaution to be taken when filling.
The main tank is half-filled with water.
- Incorporate slowly chemical through the tank filter to prevent rust or other particles.
WARNING : Avoid contamination or personal injury. Do not open suction valve
towards suction filling device unless pump is running and filling hose is connected.
If this valve is opened without running, liquid will stream out of the valve.
4-
3
-
3
FILLING THE MAIN TANK
We recommend to fill up the main tank to half capacity before incorporating chemical product.
When filling, continually check the level in the tank so as to prevent pollution by any overflowing.
Plant protection products can be added by suction or gravity.