![Hardi COMMANDER Plus 1200 Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/hardi/commander-plus-1200/commander-plus-1200_operators-manual_597227049.webp)
47
HARDI
®
COMMANDER OPERATOR’S MANUAL
Cone check/replacement ECP operating unit
If it becomes difficult to build up sufficient pressure or if
pressure fluctuations occur, it may be necessary to
replace the cone and cylinder. A HARDI
®
kit is available
for this purpose. Ref. no. 741293.
1. Remove 4 x screws
A
and remove the housing.
2. Remove 4 x screws
B
.
3. Replace cylinder
C
and O-ring
D
.
4. Loosen the nut
E
, remove and replace
the cone
F
.
5. Reassemble in reverse order.
Cone check/replacement,
ECP distribution valve
Periodically check the distribution
valves for proper sealing. Do this by
running the sprayer with clean water
and open all distribution valves.
Cautiously remove the clip
A
and
pull out the hose
B
for the pressure
equalization device. When the
housing is drained, there should
be no liquid flow through the
pressure equalization device. If
there is any leakage, the valve
cone
E
must be changed.
Remove the clip
C
and lift the
motor housing off the valve
housing. Then unscrew the
screw
D
and replace the
valve cone
E
. Reassemble in
reverse order.
B
A
C
D
E
F
Pump valves and diaphragms replacement
(1302 pumps)
NOTE!
It is recommended that if one or more
diaphragms and/or valves need replacing they all
should be replaced.
Diaphragm pump overhaul kit (valves, seals, dia-
phragms, etc.)
Pump model
HARDI
®
part No.
1302
750175
Changing valves
1
Remove the valve covers (
A
). Before changing the
valves (
B
) note their orientation so they are re-
placed correctly. It is recommended to use new O-
rings (
C
) when changing or checking the valves.
Changing diaphragms
1
Remove the diaphragm covers (
D
).
2
Remove the diaphragm bolts (
E
).
3
The diaphragms (
F
) may now be changed.
4
If fluids have reached the crankcase, re-grease the
pump thoroughly. Also check the drain hole at the
bottom of the pump is not blocked.
5
Reassemble with torque settings shown below.
Torque Settings for 1302 pumps
Pump Valve Cover Diaphragm Diaphragm
Model Ft/lb(Nm) Bolt Ft/lb(Nm) Cover
1302 45 (60) 45 (60) 50 (70)
1 Ft/lb = 1.36 Nm
A
B
C
D
E
F
A = Valve Cover
B = Valves
C = O-rings
D = Diaphragm Cover
E = Diaphragm Bolt
F = Diaphragm
Maintenance
D
C
A
E
B
Содержание COMMANDER Plus 1200